IDT Configuration Registers
PES24N3A User Manual
9 - 38
April 10, 2008
Notes
AERUEM - AER Uncorrectable Error Mask (0x108)
14
COMPTO
RO
0x0
Completion Time-out Status.
A switch port does not ini-
tiate non-posted requests on its own behalf. Therefore, this
field is hardwired to zero.
15
CABORT
RO
0x0
Completer Abort Status.
The PES24N3A never responds
to a non-posted request with a completer abort.
16
UECOMP
RW1C
0x0
Sticky
Unexpected Completion Status.
This bit is set when an
unexpected completion is detected.
17
RCVOVR
RW1C
0x0
Sticky
Receiver Overflow Status.
This bit is set when a receiver
overflow is detected.
18
MAL-
FORMED
RW1C
0x0
Sticky
Malformed TLP Status.
This bit is set when a malformed
TLP is detected.
19
ECRC
RW1C
0x0
Sticky
ECRC Status.
This bit is set when an ECRC error is
detected.
20
UR
RW1C
0x0
Sticky
UR Status.
This bit is set when an unsupported request is
detected.
31:21
Reserved
RO
0x0
Reserved field.
Bit
Field
Field
Name
Type
Default
Value
Description
0
UDEF
RW
0x0
Sticky
Undefined.
This bit is no longer used in this version of the
specification.
3:1
Reserved
RO
0x0
Reserved field.
4
DLPERR
RW
0x0
Sticky
Data Link Protocol Error Mask.
When this bit is set, the
corresponding bit in the AERUES register is masked. When
a bit is masked in the AERUES register, the corresponding
event is not logged in the advanced capability structure and
an error is not reported to the root complex.
5
SDOENERR
RW
0x0
Sticky
Surprise Down Error Status.
When this bit is set, the cor-
responding bit in the AERUES register is masked. When a
bit is masked in the AERUES register, the corresponding
event is not logged in the advanced capability structure and
an error is not reported to the root complex.
11:6
Reserved
RO
0x0
Reserved field.
12
POISONED
RW
0x0
Sticky
Poisoned TLP Mask.
When this bit is set, the correspond-
ing bit in the AERUES register is masked. When a bit is
masked in the AERUES register, the corresponding event is
not logged in the advanced capability structure and an error
is not reported to the root complex.
13
FCPERR
RW
0x0
Sticky
Flow Control Protocol Error Mask.
When this bit is set,
the corresponding bit in the AERUES register is masked.
When a bit is masked in the AERUES register, the corre-
sponding event is not logged in the advanced capability
structure and an error is not reported to the root complex.
14
COMPTO
RO
0x0
Completion Time-out Status.
A switch port does not ini-
tiate non-posted requests on its own behalf. Therefore, this
field is hardwired to zero.
15
CABORT
RO
0x0
Completer Abort Status.
The PES24N3A never responds
to a non-posted request with a completer abort.
Bit
Field
Field
Name
Type
Default
Value
Description
Содержание 89HPES24N3A
Страница 10: ...IDT Table of Contents PES24N3A User Manual iv April 10 2008 Notes...
Страница 12: ...IDT List of Tables PES24N3A User Manual vi April 10 2008 Notes...
Страница 14: ...IDT List of Figures PES24N3A User Manual viii April 10 2008 Notes...
Страница 18: ...IDT Register List PES24N3A User Manual xii April 10 2008 Notes...
Страница 38: ...IDT Clocking Reset and Initialization Clock Operation PES24N3A User Manual 2 10 April 10 2008 Notes...
Страница 64: ...IDT Link Operation PES24N3A User Manual 4 8 April 10 2008 Notes...
Страница 88: ...IDT Power Management PES24N3A User Manual 7 4 April 10 2008 Notes...
Страница 160: ...IDT Configuration Registers PES24N3A User Manual 9 66 April 10 2008 Notes...