Installation instructions TERRA SWM
11
Description
Heat pump type
Unit
TERRA SWM 3-13
Maximum
fl
ow temperature
°C
62
Refrigerant
-
R410A
Quantity of refrigerant
kg
3.0
CO
2
- Equivalent
t
6.3
Compressor oil
EMKARATE RL 32-3MAF
Quantity of compressor oil
l
0.74
Compressor stages
-
1-stage modulated
Integrated brine pump
Wilo Stratos Para 15/1-9
Nominal
fl
ow rate ground water with safety heat exchanger
m³/h
2.16
Pressure loss ground water side with safety heat exchanger
kPa
13.4
Integrated loading pump
Wilo Stratos Para 15/1-9
Nominal
fl
ow heating water
m³/h
1.5
Free residual pressure loading pump at nominal speed
2)
kPa
45.4
Pressure loss heating side at nominal speed
2)
kPa
8.6
Maximum operating pressure heating side / brine side
bar
3
Heating
fl
ow / -return
fl
ow
R
1“
Electrical power supply compressor
V / Hz
3~ 400 / 50
Electrical power supply controller
V / Hz
1~ 230 / 50
Max. operating current of compressor
A
9
Starting current
A
< 9
Power factor
0.97
Fuse of main power supply heat pump
A
13
Fuse of control main supply
A
13
1
If the size of the installation room is lower than the required minimum size, the room must be performed as an engine room according to EN 378.
2
at 80% pump capacity