10. Magnesium protection anode
Installation instructions iPump A 2-7, 3-11
50
magnesium protection anode
Ka
p
ite
l 10
10.3. Exchange of the magnesium protec-
tion anode
Before the anode is unscrewed, the bu
ff
er must be
emptied. The drain valve is located on the underside
of the bu
ff
er. For draining a hose must be connected.
In order to protect the underlying electric from any
escaping residual water, it is best to cover it with a
foil.
The black connection line between the anode and the
bu
ff
er must be terminated.
Then the anode can be unscrewed by a suitable pipe
wrench.
The used magnesium protective anode can now be
pulled out and replaced by a new one.
The new anode will be screwed
fi
rmly and the black
connection cable between the anode and the bu
ff
er
must be pluged.
After re
fi
lling the bu
ff
er, it must be checked for leaks
in the area of the protective anode.