(C) IDM ENERGIESYSTEME GMBH

7. Electrical assembly

Installation instructions AERO SLM

38

electrical assembly

Inbetri

e

b

n

ahm

e

7.5. Disassembly the cover

Before the electrical connection of the heat pump the 
cover has to be removed. First, the front part with the
NAVIGATOR 2.0 touch display has to be dismount. 
To remove the front panel, the interlocking device 
must be opened with a screw driver or a pointed 
object. The interlocking device is behind the white 
cover, around 1 cm above the edge of the unit. By 
pressing the locking bolt, the lock of the front panel 
will be released.

When removing the front panel, make sure that the 
connection cable between the control panel and the 
motherboard is disconnected.

The cover is 

fi

 xed with two screws. After removing 

the screws, the cover can be pulled forward. Now, 
the cover can be lifted up and the earthing cable can 
be removed. Afterwards the connection terminals are 
freely accessible.

Consider the note for opening!

Disconnect the cable to the control panel

Remove the fastening screws

Pull the cover forward and remove it

Remove the earthing cable

When disassembling the front panel and the control 
unit is already connected, make sure that the con-
necting cable between the control unit and the central 
unit is only approx. 1.5 m long.
When removing the panel, the connecting cable 
should not be exposed to tensile stress. To comple-
tely remove the panel, the connection cable on the 
central unit must be unplugged.

Содержание AERO SLM 3-11

Страница 1: ...T HGL with NAVIGATOR 2 0 control WI with NAVIGATOR 2 DIE ENERGIEFAMILIE TECHNICAL DOCUMENTATION INSTALLATION INSTRUCTIONS HEAT PUMPS FROM AUSTRIA www idm energie at 812579 Rev 8 1 Translation of origi...

Страница 2: ...nnections outdoor unit AERO SLM 3 11 10 3 7 Dimensions outdoor unit AERO SLM 6 17 11 3 8 Connections outdoor unit AERO SLM 6 17 11 3 9 Technical data 12 3 10 Performance data AERO SLM 3 11 acc to EN 1...

Страница 3: ...opening 35 6 5 Installation of refrigerant connection pipes 35 6 6 Important information about installation of refrigerant pipes 35 7 ELECTRICAL ASSEMBLY 36 7 1 Electrical power supply 36 7 2 Electro...

Страница 4: ...o and secured against unintentional restart In addition all safety instructions in the relevant do cumentation stickers on the heat pump itself and all other applicable safety regulations must be obse...

Страница 5: ...y the customer if required 1 9 Cleaning If necessary the indoor and the outdoor unit of the AERO SLM can be cleaned with a damp cloth The use of cleaning agents is not recommended 1 10 Ser vicing and...

Страница 6: ...umans the legislation defines limit values that must not be exceeded Sound propagation outdoor With increasing distance from a point noise source the sound power is distributed on an increasing area d...

Страница 7: ...incorporation 3 or 6 dB A Impulsiveness 0 3 or 6 dB A Daytimes with increased sensitivity 6 dB A The rating level Lr shall be obtained by summing the calculated immission level and the applied correc...

Страница 8: ...of single and multiple dwellings with the heat source air In this case the building should be equipped with a low tem perature heating systems e g underfloor heating wall heating or low temperature r...

Страница 9: ...LHZ 6LGH YLHZ OHIW RWWRP YLHZ 3 3 Dimensions indoor unit AERO SLM 3 11 and AERO SLM 6 17 1 HGL flow 2 Heatpump flow 3 Heat pump return 4 Cable inlet main current 5 Refrigerant pipes 6 LAN Connection 7...

Страница 10: ...10 description Montage Heizungsseitig Front view Side view left Inlet side Outlet side 3 5 Dimensions outdoor unit AERO SLM 3 11 Refrigerant pipe connections 12 mm und 16 mm Condensation drain 1 Outle...

Страница 11: ...scription Montage Heizungsseitig 3 7 Dimensions outdoor unit AERO SLM 6 17 3 8 Connections outdoor unit AERO SLM 6 17 Front view Side view left Inlet side Outlet side RQGHQVDWH UXQ RII VRFNHW 5HIULJHU...

Страница 12: ...mption at A35 C W18 C kW 1 81 2 70 EER at A35 C W18 C 4 32 4 43 Sound emission acc to EN 121021 Sound power level nominal indoor unit dB A 45 45 Sound power level maximum indoor unit dB A 48 55 Sound...

Страница 13: ...outdoor unit m 20 m max height di erence 10 m2 Electrical data Electrical power supply compressor V Hz 3 400 50 1 230 50 3 400 50 Electrical power supply heating unit V Hz 3 400 50 1 230 50 3 400 50...

Страница 14: ...7 7 85 8 40 W k Power intake 1 56 1 56 1 60 1 61 1 64 1 63 1 60 1 60 1 59 1 55 W k COP Heizleistung 2 80 2 80 2 80 2 80 2 80 2 80 2 80 3 21 3 80 4 42 W k Power intake 2 24 1 93 1 56 1 39 1 08 0 76 0 6...

Страница 15: ...4 2 2 6 2 0 8 2 4 0 3 8 3 3 W k 2 7 4 5 2 4 8 7 3 0 3 3 3 8 2 5 3 2 R E E Cooling capacity 3 9 6 5 5 6 7 1 6 8 7 5 0 4 5 2 0 5 W k Power intake 9 3 1 5 4 1 2 5 1 1 6 1 4 7 1 1 9 1 W k 0 0 5 3 5 4 6 0...

Страница 16: ...sseitig Heat output AERO SLM 3 11 at flow temperature 35 C Heat output AERO SLM 3 11 at flow temperature 45 C 0 2 4 6 8 10 12 14 20 15 10 5 0 5 10 15 20 Heat output kW Air inlet temperature C MAX NOMI...

Страница 17: ...g Heat output AERO SLM 3 11 at flow temperature 55 C Heat output AERO SLM 3 11 at nominal speed 0 2 4 6 8 10 12 14 20 15 10 5 0 5 10 15 20 Heat output kW Air inlet temperature C MAX NOMINAL MIN 2 3 4...

Страница 18: ...AERO SLM 18 description Montage Heizungsseitig 3 12 Performance data AERO SLM 6 17 acc to EN 14511 heating t W t KW t W t KW t W t KW t W t KW t W t KW t W t KW t W t KW t W t KW t W t KW t W t KW t W...

Страница 19: ...2 19 1 80 PPMJOH DBQBDJUZ kW 1PXFS JOUBLF kW EER 13 35 12 57 11 77 10 91 10 01 9 18 2 87 2 60 2 35 2 11 1 89 1 70 7 85 6 64 5 57 4 64 3 85 3 20 PPMJOH DBQBDJUZ kW 1PXFS JOUBLF kW EER 6 29 6 14 6 13 6...

Страница 20: ...structions AERO SLM 20 description Montage Heizungsseitig Heat output AERO SLM 6 17 at flow temperature 35 C Heat output AERO SLM 6 17 at flow temperature 45 C HDW SRXWSXW kW LU LQOHW WHPSHUDWXUH C D...

Страница 21: ...ructions AERO SLM 21 description Montage Heizungsseitig Heat output AERO SLM 6 17 at flow temperature 55 C Heat output AERO SLM 6 17 at nominal speed HDW RXWSXW kW LU LQOHW WHPSHUDWXUH C D EKD D E HDW...

Страница 22: ...ant Up to a distance of 6 m between indoor and outdoor unit no additional refrigerant needs to be refilled For pipe length more than 6 m the following refrigerant quantities must be refilled 0 0 1 0 2...

Страница 23: ...ng water quality see page 44 Heat pumps are by nature subjects to limits of use regarding of pressure and temperature see diagram It is not permissible to operate the AERO SLM 3 11 and AERO SLM 6 17 o...

Страница 24: ...is the lowest temperature that the heat pump can produce depending on the heat source temperature and is then switched off at this value Due to the hydraulic spread across the heat pump the control re...

Страница 25: ...uring the transport shall be present If the heat pump must be transported without the wooden pallet and the protective wooden crate it is important that there will be no damage on the housing Transpor...

Страница 26: ...tructure borne sound transmissi ons the heat pump must be installed on a horizontal level and weight bearing surface concrete plate or similar In the case of floating screed the screed and the impact...

Страница 27: ...anel will be released The front panel can be unhinged out by gently lift up After the front panel is removed the fixing screws of the side parts will be loosed The fixing screws are located on the fro...

Страница 28: ...is recommended to put powder in to insulation Then the insulation can be pushed more easily over the connecting hoses Before connecting the hoses the supplied rubber grommets must be pushed over the...

Страница 29: ...lected such that no noise interference can occur do not install close to bedrooms keep distance from neighbours hedges and bushes can absorb noise A frost proof connection of the condensation run o is...

Страница 30: ...capacity of the wall bracket must be given Air heat pumps are producing condensation water during operation This could be 6 liters per defrost cycle within 2 minutes The condensate run o must be frost...

Страница 31: ...the threaded bars After this the outdoor unit will be placed and brought into the correct position At the end the outdoor unit will be countered and secured with the washers and the hexagon nuts Moun...

Страница 32: ...dapter The heating band 2 m will be placed in the drain hose The condensation bin and the run o have to be checked for soiling regularly Outdoor device Well Pipe 300mm Canalisation Condensate flow com...

Страница 33: ...delivery They are available as an accessory and can be ordered by the iDM dealer 6 2 Connection of the outdoor unit on refri gerant side The refrigerant pipes are factory fitted with protective caps B...

Страница 34: ...n of bending the refrigerant pipes on the backside of the heat pump in the appropriate direction depending on the desired routing of the refrigerant connection pipes see the red and green dashed lines...

Страница 35: ...refrigerant itself may only be handled by trained experts autho rised by iDM Energiesysteme GmbH The refrigerant flow through the indoor unit can lead to flow noises The refrigerant pipes must be unco...

Страница 36: ...conditions me chanical load current load potential drop environ mental temperature UV resistance electromagnetic compatibility Before commissioning the system check all terminals and tighten if neces...

Страница 37: ...1x230V F B Z13A Indoor unit Refrigerant connection pipes Wall opening Outdoor unit Network cable Main current 3 400V 1 230V F C K13A C K16A C K25A Electrical heating element 3 400V 1 230V F B Z13A B...

Страница 38: ...nnection cable between the control panel and the motherboard is disconnected The cover is fixed with two screws After removing the screws the cover can be pulled forward Now the cover can be lifted up...

Страница 39: ...33 31 N 30 29 28 N 26 27 25 N 24 23 N N 22 N N 21 20 EEV1 X2 EEV2 X4 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52...

Страница 40: ...re operating conditions etc to be exchanged and processed between the devices Add on module for Solar The NAVIGATOR 2 0 enables a temperature di eren tial controlled solar charging A layered solar inj...

Страница 41: ...and the set shut o temperature changed if necessary If the heat pump is to be drained on the heating side the connection hose on the heat pump return must be disconnected At air source heat pumps a he...

Страница 42: ...alve AERO SLM 3 11 HGL Hygienik Direct circuit for heating and cooling The heating system must be designed for cooling mode The cool demand of the building and the power output capacity of the distrib...

Страница 43: ...HC A FS Refrigerant pipes Note This is only a tentative suggestion for installing an IDM heat pump in the heating system This suggestion replaces no professional planning of an executing companie On...

Страница 44: ...he heat pump or high pressure faults For this reason open heating systems or steel pipe installations in combination with plastic pipe under floor heating which is not di usion tight should be avoided...

Страница 45: ...FKQLFDO DWD RX FDQ ILQG RQ WKH QDPHSODWH FKDQJH WR WKH GHYLFH V QRW DXWKRUL HG E XV ZLOO UHQGHU WKLV GHFODUDWLRQ LQYDOLG 8 LUHFWLYHV RZ 9ROWDJH LUHFWLYH 8 0 LUHFWLYH 8 FRGHVLJQ LUHFWLYH 8 3UHVVXUH TXL...

Страница 46: ...y efficiency s cold 150 120 average 176 135 warm 217 175 seasonal Coefficient of Performance SCOP kalt 3 82 3 07 mittel 4 47 3 44 warm 5 54 4 45 rated heat output Prated kW cold 10 9 average 9 8 warm...

Страница 47: ...74 131 average 206 153 warm 252 195 seasonal Coefficient of Performance SCOP cold 4 41 3 35 average 5 22 3 83 warm 6 38 4 95 rated heat output Prated kW cold 15 12 average 14 11 warm 17 16 annual ener...

Страница 48: ...d 1 95 2 02 2 36 indoor temperature 20 C indoor temperature 20 C T j Operation limit temperature TOL P dh 6 9 8 5 9 9 kW T j Operation limit temperature TOL COP d 1 82 2 02 2 36 Bivalenz temperature T...

Страница 49: ...06 2 34 T j Operation limit temperature TOL P dh 8 9 10 9 15 9 kW T j Operation limit temperature TOL COP d 1 87 2 06 2 34 Bivalenz temperature Tbiv T biv 15 0 10 0 2 0 C Operation limit temperature...

Страница 50: ...SITE SERVICE Our service technicians are happy to help on site Contact details for your regional customer service centre can be found on our website iDM Akademy PRACTICAL KNOWLEDGE FOR SALES AND TECH...