(C) IDM ENERGIESYSTEME GMBH
Installation instructions AERO ILM
9
Technical data
Heatpump type
unit
AERO ILM 2-7
AERO ILM 4-13
Maximum heatpump flow temperature
&
62
60
1RPLQDOIORZUDWHKHDWLQJZDWHU$&:&ǻ7 .
m³/h
0.8
1.42
)ORZUDWHKHDWLQJZDWHU$&:&ǻ7 .
m³/h
0.42
0.77
Integrated loading pump
Yonos Para 7.0
Stratos Para 25/1-9
Free residual pressure loading pump at nominal flow rate
kPa
49
77
Pressure loss heating side
kPa
15
11
Flow- and return connections heating side
R
1“ AG
1“ AG
Flow domestic hot water heater or HGL-flow
R
1“ AG
1“ AG bzw. 5/4“ AG
&RQGHQVDWHUXQRIIFRQQHFWLRQ
R
35 mm
35 mm
Maximum operating pressure heating side
bar
3
3
Integrated fan-type
Radialventilator
Radialventilator
Residual pressure at maximum speed ¹
Pa
150
110
1RPLQDODLUIORZUDWH$&:&
DQGQRPLQDO&RPSUHVVRUVSHHG
m³/h
1,250
2,200
diameter flexible air outlet hose (accessory)
mm
560
560
Refrigerant
R410A (GWP
3
2088)
R410A (GWP
3
2088)
Quantity of refrigerant
2
kg
3.2
6.2
&2
2
-Equivalent
3
t
6.7
12.9
Minimum size of installation room
m³
7.3
14.1
Quantity of compressor oil (FV50S)
lt.
0.35
1.9
Quantity of compressors
qty
1
1
1
If the fan speed will be raised, the sound power level raises too
ð$(52,/0KHDWSXPSVZRUNZLWKWKHE\WKH.\RWRSURWRFROGHWHFWHGVDIHW\UHIULJHUDQW5$ZLWKDJOREDOZDUPLQJSRWHQWLDORI
3
&2
2
-equivalent filling quantity (GWP x refrigerant filling quantity)
Electrical data
unit
AERO ILM 2-7
AERO ILM 4-13
Electrical power supply compressor
V/Hz
1~ 230/50
3~ 400/50
Electrical power supply heating element
V/Hz
3~ 400/50 or
1~ 230/50
3~ 400/50
Electrical power supply controller
V/Hz
1~ 230/50
1~ 230/50
Maximum operating (starting) current of compressor
A
15.8
19.0
Maximum power consumption electric heating element
A
8.7
8.7
Fuse of control supply
A
B/Z 13
B/Z 13
Fuse of electrical heating element
A
if 3~ 400/50 B/Z 13
if 1~ 230/50 B/Z 32
B/Z 13
Fuse of main power supply compressor
A
&.
&.
Maximum operating current of fan
A
0.24
0.5
Maximum power consumption fan
W
56
115