MSD-54 SERIES User
’s Guide
158
For details of
the settings below, see ”
*
1
If you set “DELAY” to a value other than “0”, command execution is delayed according to the set value.
Control command number to be executed and remaining time before the command execution are displayed
by 100 ms.
*
2
Th
is depends on setting of “PORT”.
*
3
The send control command data set in
“ is sent for the number of bytes
specified in “SIZE”.
*
4
If you set “RECV DSPLAY” to “ASCII” or “HEX”, the received data is displayed on VFD screen in “ASCII” or
“HEX”.
*
5
If you set
“DELIMITER” to a value other than “NONE”, the MSD waits until it receives the set delimiter.
*
6
If you set “DELIMITER” to “NONE”, the MSD waits the receive data until the time set for “TIME OUT”
passes. If no data is received, the MSD retries.
*
7
If you se
t “RCV” to “NOT CHECK” for all (32) commands, the next command will be performed without
checking reply commands. If you set it to “CHECK” for only one command, the reply command is compared
with the received data in order of ”1
→
2---31
→
32”.
*
8
If received
data matches “DATA” of “RECV COMMAND” registered in ”
“, the next
operation will be determined according to “PROCESS” of ”
“. If you set
“PROCESS” to “RETRY”, the retry operation will be performed. If you set it to “EXEC”, the next command
will be executed. I
f you set it to “STOP”, the next command will not be executed even if the next command
is associated.
*
9
If a delimiter or
data matching reply command is not received even after the time set in ”TIME OUT” passes,
it causes timeout and retries the operation.
*
10
If any reply command is not received, the send command data is resent for the number of replies set
in ”RETRY”. If you set “RETRY” to “0”, the command is not resent.
*
11
If you set “INTERVAL” to an interval other than “0”, retry will be delayed according to the set time.
*
12
If the reply command is not sent even after retry for the number of retry times set in “RETRY,” the next
operation will be determined according to ”ERROR”. If you set “ERROR” to “EXEC”, the next command will
be executed autom
atically. If you set it to “STOP”, the next command will not be executed even if the
command is associated. If you turn multiple communication ports “ON”, it becomes “RETRY OVER
ERROR” unless reply commands from all communication ports to which commands are sent are received.
*
13
The connector that is set to “OFF”, “ON,” or ” TGL” for ”Tally” will be controlled.
*
14
If you set ”PULSE” of “Tally” to a value other than “NONE”, the contact point is put back to the previous
(that of before controlling contact points) status automatically after the set time passes.
*
15
The connector that is set to “POWER OFF” or “POWER ON” for ”HDMI CEC control” will be controlled.
*
16
If no response from a device controlled with CEC, the next operation will be determined according to the
setting of ”
“. If you set “ERROR” to “EXEC”, the next command will be executed,
bu
t if you set it to “STOP”, the next command is not executed even if the command is associated. If you set
multiple outputs to be controlled in “HDMI CEC control” and any response from all devices controlled by
CEC are not sent, it causes an error.
[COMMAND EXEC WAIT]
No. 1 DELAY: 10.5sec