159
8.12.1 Control commands [COMMAND EDIT]
You can register up to 32 commands.
[Table 8.13] Setting items of control commands
Item
Description
Range
PORT
Select “COM”, “Tally”, or “CEC”.
COM: Communication
command [Default]
Tally:Tally output
CEC: HDMI CEC
DELAY
Set the waiting time of the control command. Use this
item for devices such as projectors that requires time
to cool down after powering off.
0 ms. to 999 seconds and 999
ms.
[Default]: 0 ms.
Communication
port
*1
Set the following communication ports to “OFF” (not
sending communication commands) or “ON” (sending
communication commands). Those ports can be set
separately, and communication commands can be
sent to multiple communication ports at the same
time.
RS1: RS-232C CH1
*6
RS2: RS-232C CH2
*6
LOOP BACK: Internal loop back
LAN1 to LAN8: LAN connections 1 to 8
*7
OFF [Default]
ON
COM SIZE
*1
Set the number of bytes to be sent starting with the
first byte.
0 byte to 30 bytes
[Default]: 0 byte
COMMAND
INPUT MODE
*1
Set the input mode of send command data. Select
“ASCII” if “DATA” of “COMMAND” consists of only 0A,
0D, and 20 to 7D of
”; select “HEX” if
“DATA” of “COMMAND” includes other codes.
ASCII [Default]
HEX
Send command
data
*1
Set the command from the first byte according to the
number of bytes set in “COM SIEZE” (up to 30 bytes).
0A, 0D, 20 to 7D of
” (If inputting with ASCII
codes), or 00 to FF of hex (If
inputting with hex)
[Default]: 20 (Space)
(All numbers above are hex)
RECV DISPLAY
*1
Set whether received data is displayed or not.
OFF [Default]
ASCII
HEX