8.6.8 Automatic setting of input timing [UNKNOWN TIMING]
The MSD continuously monitors input signals. When signals input from analog input (IN6 to IN9) changes, it
loads the optimal table from the built- in tables and converts the signals. However, if unregistered signals are
input, the input timing must be set. By setting this menu to “ON”, “
” is executed and the input timing is set automatically if signals that cannot be detected by the
MSD are input for the first time.
・
The automatic measurement is not executed when unregistered signals are input:
AUTO SETUP OFF
・
The automatic measurement is executed when unregistered signals are input:
AUTO SETUP ON [Default]
Note 1:
If automatic
measurement finds inconsistency of aspect ratio, please perform “
” manually or set the input timing in the following menus: “
8.6.2 Horizontal start position
8.6.3 Horizontal display period
Note 2:
Only if a video having 25% or more brightness and whose edges (all sides) are in contact with the
circumscribed rectangle in the effective display area is input, the automatic measurement is valid. If the input
video does not meet these requirements, the measurement may fail or the video may be output on the correct
position. In such a case, set this menu to “OFF”.
Input image
Valid display
area
Measurable: Contacting with
circumscribed rectangle
Input image
Valid display
area
Measurable: Contacting with
circumscribed rectangle
Input image
Valid display
area
Not measurable: Right and
left not contacting with
circumscribed rectangle
[Figure 8.40] Examples of input videos
1. To set the input timing using menu:
↓ SET key
[FUNCTION SELECT]
INPUT TIMING
▲▼keys: Select “INPUT TIMING”.
↓ SET key
[INPUT TIMING]
UNKNOWN TIMING
▲▼keys: Select “UNKNOWN TIMING”.
↓ SET key
MSD-5404