29
Programming Functions
6-OUTPUTS (continued)
Duty cycle1=%
is the duty cycle for
Out1
. This defines
the ratio between the
ON
and
OFF
states. When
Out1
is set to one of the three “
#1 FREQ
” options, a value of
50% indicates the
ON
phase will be the same as the
OFF
phase; 60% indicates the phase
ON
will be 60%
and phase
OFF
will be 40% of the total cycle time.
When
Out1
is set to one of the three “
#1 IMP
” options,
the duty cycle indicates the
OFF
phase because the
ON
phase it’s already set with the function
Tpul1
set in the
2-SCALES
menu. Set the duty cycle by calculating the
minimum time of the
OFF
phase and the time of total
cycle using the following formulas:
T.total cycle
= 100 x (pulse duration in ms)÷(duty cycle)
T.OFF phase
= T. total cycle - pulse duration.
NOTE:
If
Duty cycle1=%
is set to “
0
”, the pulses are
synchronized with the flow rate, therefore, when
frequency is selected, do not set to “
0
”. This is the
recommended setting for short run applications such as
dosing.
Duty cycle2=%
is the duty cycle for
Out2
. It is defined
and set the same as
Duty cycle1=%
.
Out mA1=
is the setting for the current output range for
Fs1
. The current output setting for
Fs1
is optional. There
are three fields to modify for this function:
•
Scale zero:
0
or
4
mA
•
Full scale:
20
or
22
mA
•
Field:
+
= positive,
-
= negative,
±
= both, or
-0+
=central zero scale
The values corresponding to the scale points are shown
in the chart to the right.
In hardware alarm conditions (
HARDW AL.
) the current
value is programmed by the function
mA v.fault
in the
4-
ALARMS
menu and it is expressed as percentage of a
fixed current range, where: 0% = 0mA and 110% = 22mA.
Out mA2=
is set up the same way as
Out mA1=
. It is
only available with optional modules ME202 or ME204.
Current values in mA associate to the
% value of full scale
Reverse Flow Zero
Direct Flow
Value
Value
Possible Field
<-100% -100%
0% +100% >+100%
OutmA1= 0-20+
0
0
0
20
20
OutmA1= 0-22+
0
0
0
20
22
OutmA1= 4-20+
4
4
4
20
20
OutmA1= 4-22+
4
4
4
20
22
OutmA1= 0-20-
20
20
0
0
0
OutmA1= 0-22-
22
20
0
0
0
OutmA1= 4-20-
20
20
4
4
4
OutmA1= 4-22-
22
20
4
4
4
OutmA1= 0-20±
20
20
0
20
20
OutmA1= 0-22±
22
20
0
20
22
OutmA1= 4-20±
20
20
4
20
20
OutmA1= 4-22±
22
20
4
20
22
OutmA1= 0-20-0+
0
0
10
20
20
OutmA1= 0-22-0+
0
1
11
21
22
OutmA1= 4-20-0+
4
4
12
20
20
OutmA1= 4-22-0+
4
4.8
12.8
20.8
22
Graph of 4-20-0+
Graph of 4-22+