5-INPUTS
T+RESET=
is the reset enable for the total
direct
(positive)
flow totalizer. When this function is active, the totalizer may
be reset by applying a voltage to the on/off input or via the
keyboard. This may be set to
ON
or
OFF
. If set to off, this
totalizer can not be reset. T+ and T- Reset are continuous
totalizers and are most often not reset.
P+RESET=
is the reset enable for the partial
direct
(positive) flow totalizer. See the previous function. P+ and
P- Reset are typically reset after a process or batch.
T-RESET=
is the reset enable for the total
reverse
(negative) flow totalizer. See the previous function.
NOTE:
This function is disabled when
Batch
is set to
ON
.
P-RESET=
is the reset enable for the partial
reverse
(negative) flow totalizer. See the previous function.
NOTE:
To reset the totalizers from the keypad, follow these
instructions:
1. From any display screen press the
key.
2. Enter the proper
Keycode L2
and then push the
key. The display will prompt the operator with the
questions:
•
T+gal:RESET TOT?
•
P+gal:RESET TOT?
•
CTgal:RESET TOT?
3. Push the
key to proceed with resetting these
totalizer values. Push any other key to cancel this
operation. The questions appearing on the display
during this operation depend on which reset options
are enabled.
Pulse.reset=
is a function which enables resetting of the
totalizer from a digital input. This may be set to
ON
or
OFF
.
Programming Functions
displayed when
Batch
is enabled in the
5-INPUTS
menu.
This function is used to set a maximum time for a batch
to start, end, or to stall. If the batch takes too long to
start (flow remains at zero after start) and it exceeds this
value, it will activate an alarm. If the batch is interrupted
for a time that exceeds this value, it will activate an alarm.
If the batch is complete, but the converter senses flow
for a time that exceeds this value, it will activate an alarm.
This function is useful for controlling one or both of the
following conditions:
•
Batch valve is open and flow rate is
0
.
•
Batch valve is closed and flow rate different than
0
.
When this alarm is activated, the batch operation is
canceled and the power supply to the valve is removed,
allowing it to close. This may be set from
0
to
6,000
seconds.
4-ALARMS (continued)
OFF
ON
OFF
ON
OFF
ON
OFF
5-INPUTS
T+ RESET=
P+ RESET=
T- RESET=
P- RESET=
Pulse.reset=
Count lock=
Calibration=
OFF
OFF
Range change=
Batch=