manualshive.com logo in svg
background image

Page 6  

0901048 Rev. C 

 

Description of Screen 

Display 

1. 

Power  on the unit. 

 
For about 2 seconds you will see the screen to the right. 
 

If the system is equipped with a USB interface, the current USB version will be displayed. 

 

2. 

After about 2 seconds you will see the screen to the right. 

 

3. 

To enter the programming mode,  hold down the ENTER button until the display color changes to purple. 

 

4. 

Press the UP button to start/stop priming the detergent. The detergent will fill the detergent will fill the detergent 
suction tube. If the flow meter option is installed, the flow meter counts will be displayed. The detergent will then fill 
the detergent discharge tube. Once there is a steady flow of detergent out of the detergent discharge tube into the 
sink, press UP to stop priming. 
 
Important: 
1. Check to make sure the roller block is rotating clockwise. 
2. Ensure the FLOWMETER CTS has a numerical value. The range of values will vary. 

 

Note: If the flow meter option is installed and auto prime enabled, when the unit is primed it will use calculations form 
the prime to auto prime the unit when the detergent runs out. 

 

Press ENTER to advance to the next screen. 

 

5. 

To access the basic features in the programming mode, you will need a user pass code. To enter a user pass code, 
use the SCROLL button to scroll between digits and the UP and DOWN buttons to cycle between 0-9. By default, the 
pass code is set to 0000. 
 
Press ENTER to advance to the next screen. 

 

6. 

To change the existing user pass code, use the SCROLL button to scroll between the digits and use the UP and 
DOWN buttons to cycle between 0-9. 

 

Press ENTER to advance to the next screen. 

 

7. 

To view the reports, there are two options: 

1. 

Data download (if USB port option is installed, data will be downloaded to USB stick on coming menu 
options) 

2. 

On-Screen report (data will be displayed directly on LCD) 

 

You can choose either option by pressing the SCROLL button. When complete, press ENTER to advance to the next 
screen. 

 

Programming DoseTechDMS

 

 

USB VERSION 
Firmware Ver IXXX 

17:05:56AM 

08/15/13 

LAST DOSE VOLUME 

 000 

LEVELS A&B 

025/050 

ALARMS TODAY 

000 

PRESS UP TO START PUMP 
PRIMING 

PRESS UP TO START PUMP 
PRIMING 

 

PRESS SCROLL TO  CHANGE 
USER CODE 

 

 

PRESS SCROLL TO  CHANGE 
USER CODE 

 

 

SELECT DATA DOWNLOAD OR ON-
SCREEN REPORTS 

 

Содержание Knight DoseTech DMS

Страница 1: ...Instruction Manual 0901048 Rev C...

Страница 2: ...discharge line with check valve and attaching hardware System is not for use in potentially explosive environments Safety Symbols Listed below are explanations of the safety symbols that appear eithe...

Страница 3: ...Qty Description Check Box 1 7020120 1 Suction Cup 1 OD Vinyl 2 7901200 1 Check Valve PDI Cracking Pressure x Barb Viton 3 0300121 10 Cable Ties 4 0200009 4 Cable Tie Mounts 5 7020152 4 Clamp Nylon Sna...

Страница 4: ...t Note Itisimportanttomountthe dispenseronahard flatsurface thatislevel SeeFig 4 7 Cutoutthetemplateonpage22formountingthedispenser Placethetemplateagainstthe surfacethatthedispenserwillbemountedto Us...

Страница 5: ...up to 12 feet Do not pull on the remote control unit to pull the cables out Roll up the left over cables and place them back into the dispenser Close the control cover and tighten the strain reliefs S...

Страница 6: ...ulations form the prime to auto prime the unit when the detergent runs out Press ENTER to advance to the next screen 5 To access the basic features in the programming mode you will need a user pass co...

Страница 7: ...between digits and the UP and DOWN buttons to cycle between 0 9 By default the pass code is set to 0000 Press ENTER to advance to the next screen 12 To change the existing main pass code use the SCRO...

Страница 8: ...the UP and DOWN buttons to set the numerical value for the amount of detergent you wish to dispense for each volume Press ENTER to advance to the next screen 20 To set your preferred method of dosing...

Страница 9: ...to ensure the sink is filled with water to meet your minimum setting but not exceed your maximum Any variation below the minimum or above the maximum will set the alarm off Press ENTER to advance to...

Страница 10: ...the dispenser has been in idle insert USB stick and press UP to upload Once upload is complete the screen will display Done Note Graphic needs to be 128 x 64 pixels in size black and white in a bmp f...

Страница 11: ...lt selection To choose between level A or level B press A or B button Press START to begin dispensing for the selected level The dispenser will begin pumping in either time based mode or flow meter ba...

Страница 12: ...imed Replace the detergent container then press START to begin automatic re printing 17 05 56AM 08 15 13 LAST DOSE VOLUME 000 LEVELS A B 025 050 ALARMS TODAY 000 TEMP OUT OF RANGE Chemical empty Repla...

Страница 13: ...78 8 21 2013 8 48 38AM 50 77 8 21 2013 8 49 21AM 24 77 Out of Chem 8 21 2013 8 49 54AM 20 77 Out of Chem 8 21 2013 8 50 33AM 23 78 Out of Chem 8 21 2013 8 50 49AM 50 77 8 21 2013 8 51 39AM 50 75 Temp...

Страница 14: ...ystem should NEVER attempt removal or installation of the pump faceplate and should be made aware of this by the Responsible Body Access to internal parts are for Responsible Body i e service personne...

Страница 15: ...ad 4 Screw Stainless Steel 17 1600266 1 Control Box Cover Remote Wall Bracket 18 7140817 1 Circuit Board Assembly 19 1600708 1 Temperature Probe 20 2000519 1 Power Supply 40W 24VDC 1 67A Local Country...

Страница 16: ...Page 16 0901048 Rev C DoseTech DMS Parts Diagram...

Страница 17: ...0901048 Rev C Page 17 DoseTech DMS Wiring Diagram...

Страница 18: ...Page 18 0901048 Rev C...

Страница 19: ...0901048 Rev C Page 19 Notes...

Страница 20: ...Page 20 0901048 Rev C Notes...

Страница 21: ...0901048 Rev C Page 21 Notes...

Страница 22: ...Page 22 0901048 Rev C DoseTech DMS Mounting Template...

Страница 23: ...0901048 Rev C Page 23...

Страница 24: ...ection Bearings and pump seals or rubber and synthetic rubber parts such as O rings diaphragms squeeze tubing and gaskets are considered expendable and are not covered under warranty Warranty does not...

Страница 25: ...0901048 Rev C Page 25...

Страница 26: ...49 595 4801 USA Toll Free Tel 800 854 3764 Fax 800 752 9518 Knight Canada Tel 905 542 2333 Fax 905 542 1536 Knight Europe Tel 44 1323 514855 Fax 44 1323514828 Knight Australia Tel 61 02 9352 1801 Fax...

Отзывы: