6
©Godiva Ltd. Our policy is one of continuous development. We therefore reserve the right
to amend specifications without notice or obligation.
Essential installation data
Fastening bolts, pump to chassis
cross-member
Use 3/4” UNC or M18 fasteners four off,
minimum strength grade 8.8.
Alignment of pump drive lines
7° Effective joint angle – maximum.
Tank to suction pipework
No tank to pump connection.
Pump speed sensor (accessory)
A mechanical tachometer is available
Godiva part UFP2568. Please contact
sales for the drive cable.
Pump weight
321kg
Pump connections
Flexible joints are required to be fitted
by the vehicle builder to include the
drive coupling, the suction coupling, and
the delivery connection.
Cooling
A thermal relief valve, to prevent
overheating If the pump is operated
without discharging water for a long
period, is available to purchase from
Godiva. If this option is not chosen, the
vehicle builder should install a cooling
system to prevent overheating.
Pressure
If the pump will be used above the
18
Bar
discharge pressure, then the
vehicle builder
must
add a way to
ensure this does not happen. For
instance by incorporating a pressure
relief valve.