Seite 24/36
AWG | Instructions manual | Alco Power Fighter Manual Monitors
Assembly
5.3
Tightening torques for flange mounting
•
Tightening torques in accordance with the grade of bolt used; for aluminium flanges, max.
70 - 80 Nm.
–
For the correct order, see Fig. 5-1 to Fig. 5-5 .
–
First pass: Tighten bolts to 60% of the maximum torque, working diagonally.
–
Second pass: Tighten bolts to the full maximum torque, working diagonally.
–
Third pass: Working clockwise, tighten bolts again to the full maximum torque.
Fig. 5-1 Tighten bolts diagonally / 8 bolts, spacing 45°
Fig. 5-2 Tighten bolts diagonally / 12 bolts, spacing 30°
Fig. 5-3 Tighten bolts diagonally / 16 bolts, spacing 22.5°
1
2
5
8
4
3
6
7
1
2
5
8
4
3
6
7
12
9
11
10
1
2
5
8
4
3
6
7
12
9
11
10
16
14
13
15