Страница 1: ...Courtesy of Steven Engineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www stevenengineering com ...

Страница 2: ...EC SmartRelay s place in information technology The wiring information in your IDEC SmartRelay manual is also found in the IDEC SmartRelay Product Info included with all devices For further information on programming the IDEC SmartRelay on your PC refer to the Online Help for WindLGC WindLGC is the programming software for PCs It runs un der Windows and helps you to get started with IDEC SmartRela...

Страница 3: ...alog output values for RUN STOP transition may be selected Analog inputs and analog outputs have been added to the RUN mode display New features of the current devices FL1D The Analog Ramp Control special function enables you to use a two step speed control The Analog multiplexer special function enables you to select 1 of 4 analog values to be output The PI controller special function enables you...

Страница 4: ...nd systems in accordance with safety regula tions and standards Danger Warns that death serious harm to health or damage to assets will result if the respective precautionary measures are not taken Warning Warns that death serious harm to health or damage can result if the respective precautionary measures are not taken Caution Warns that harm to health or damage to assets can result if the re spe...

Страница 5: ... be ruled out Any liability and warranty for the accuracy of this information is excluded The data in this manual are reviewed at regular intervals Any corrections required are included in the subsequent editions Suggestions for improvement are welcomed Warning This device must always be used as intended for the applications described in the catalog and in the technical specifications and only in ...

Страница 6: ...ecting the AS interface bus 44 2 4 Putting into operation 46 2 4 1 Switching on the IDEC SmartRelay Power On 46 2 4 2 Operating states 50 3 Programming IDEC SmartRelay 52 3 1 Connectors 54 3 2 Blocks and block numbers 57 3 3 The way to IDEC SmartRelay starting with the circuit diagram 60 3 4 The four golden rules for operating IDEC SmartRelay 63 3 5 Overview of IDEC SmartRelay menus 65 3 6 Writing...

Страница 7: ...2 2 AND with Edge Detection 115 4 2 3 NAND not AND 116 4 2 4 NAND with Edge Detection 117 4 2 5 OR 118 4 2 6 NOR not OR 119 4 2 7 XOR exclusive OR 120 4 2 8 NOT Negation Inverter 120 4 3 Basics on special functions 121 4 3 1 Designation of the inputs 122 4 3 2 Time response 123 4 3 3 Backup of the real time clock 124 4 3 4 Retentivity 124 4 3 5 Parameter protection 124 4 3 6 Calculating the gain a...

Страница 8: ...23 Message texts 199 4 4 24 Softkey 206 4 4 25 Shift register 210 4 4 26 Analog multiplexer 213 4 4 27 Analog Ramp Control 217 4 4 28 PI controller 222 5 Configuring IDEC SmartRelay 229 5 1 Selecting parameter assignment mode 230 5 1 1 Parameters 232 5 1 2 Selecting the parameters 233 5 1 3 Modifying parameters 234 5 2 Setting the default values for IDEC SmartRelay 237 5 2 1 Setting the time of da...

Страница 9: ...rol system with IDEC SmartRelay 264 8 2 4 Special features and expansion options 267 8 2 5 Extended solution with FL1D H12RCC 267 8 3 Air conditioning system 270 8 3 1 Requirements for an air conditioning system 270 8 3 2 Advantages of using IDEC SmartRelay 273 8 4 Factory door 275 8 4 1 Requirements for a gate control system 275 8 4 2 Previous solution 276 8 4 3 Extended IDEC SmartRelay solution ...

Страница 10: ...M08C2R2 295 A 3 Technical data FL1D H12SND and FL1B M08B1S2 298 A 4 Technical data FL1D H12RCA FL1D B12RCA and FL1B M08D2R2 301 A 5 Technical data FL1D H12RCE FL1D B12RCE and FL1B M08B2R2 304 A 6 Switching capacity and service life of the relay outputs308 A 7 Technical data FL1B J2B2 309 A 8 Technical data FL1D K2B2 310 B Determining the cycle time 311 C IDEC SmartRelay without display 313 D IDEC ...

Страница 11: ...and apparatus engineer ing e g for gate control systems air conditioning systems or rainwater pumps etc IDEC SmartRelay can also be implemented for special con trol systems in conservatories or greenhouses for control signal processing and by connecting a communication mod ule e g AS Interface for distributed local controlling of ma chines and processes Special versions without operator panel and ...

Страница 12: ... DC and are equipped with two analog inputs or two analog outputs The digital analog modules are integrated in two subunits Each one is equipped with two expansion interfaces for con necting additional modules Which communication modules are available IDEC SmartRelay communication module FL1B CAS2 which is described in more detail in a separate documen tation The communication module has four virt...

Страница 13: ...the housing prevent you from connecting devices of a different voltage class Exception The left hand interface of an analog module or commu nication module is galvanically isolated This type of expansion module can therefore be connected to devices of a different voltage class See also Chapter 2 1 Each IDEC SmartRelay Base provides the following connections for the creation of the circuit program ...

Страница 14: ... Module slot with cap 8 Expansion interface 12 Version number example represents Version 1 1 2 3 I7 I8 Q1 Q2 Q3 Q4 4 35 72 L1 N 4 90 55 I5 I6 I2 I3 I4 I1 Q4 Q1 Q2 35 L1 N I2 I3 I4 I1 36 RUN STOP 90 53 3 1 2 9 9 10 8 8 8 10 11 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 5 6 7 4 Q3 12 12 IDEC SmartRelay Base e g FL1D H12RCC IDEC SmartRelay expansion module e g FL1B M08C2R2 X 2 3 4 ngineering Inc 230 Ryan Way So...

Страница 15: ... expansion module e g FL1B M08B2R2 Getting started with IDEC SmartRelay 5 IDEC SmartRelay Manual 1 Power supply 5 Control panel not with FL1D B12 9 Mechanical coding pins 2 Inputs 6 LCD not with FL1D B12 10 Mechanical coding sockets 3 Outputs 7 RUN STOP indicator 11 Slide 4 Module slot with cap 8 Expansion interface 12 Version number ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 Ge...

Страница 16: ...STOP indicator 11 Slide 13 Version number 8 Expansion interface 1 Power supply 9 Mechanical coding pins 12 PE terminal for con necting earth 2 Outputs 10 Mechanical coding sockets 7 RUN STOP indicator 11 Slide 13 Version number 8 Expansion interface I1 PE INPUT2x 0 10V 0 20mA 35 L M 36 RUN STOP 90 53 1 7 9 9 10 8 8 11 M1 U1 M2 U2 I2 12 4 L M 2 13 ngineering Inc 230 Ryan Way South San Francisco CA ...

Страница 17: ...r of Inputs and Outputs d B1 24V DC B2 12 24V DC C2 100 240V AC DC D2 24V AC DC e S Tr source output R Relay output f Terminal type 2 non removable terminal Analog input module FL1B Jcde c Number of Inputs d Resolution B 10bit e Terminal type 2 non removable terminal Analog output module FL1D Kcde c Number of Outputs d Resolution B 10bit e Terminal type 2 non removable terminal Communication modul...

Страница 18: ...with 8 inputs and 4 outputs The digital module is equipped with 4 digital inputs and 4 digital outputs The analog module is equipped with 2 analog inputs or two analog outputs The communications module CM e g AS Interface is equipped with 4 virtual inputs and 4 virtual outputs ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 19: ...FL1D B12RCA 2 24 V AC 24 V DC 8 digital 4 relays 10A no display unit no keyboard FL1D B12RCC 3 100 240V AC DC 8 digital 4 relays 10A no display unit no keyboard Symbol Description Supply Voltage Inputs Outputs Properties 1 Of those can be used alternatively 2 analog inputs 0 10V and 2 fast inputs 2 The digital inputs can be operated with P or N action 3 Two groups consisting of 4 inputs each Each ...

Страница 20: ... digital 4 relays 5A FL1B M08C2R2 100 240 V AC DC 4 digital 2 4 relays 5A FL1B J2B2 12 24 V DC 2 analog 0 10 V or 0 20 mA 3 none FL1D K2B2 24 V DC none 2 analog 0 10 V DC Symbol Description Supply Voltage Inputs Outputs 1 Digital inputs can be operated either with P or with N action 2 Different phases are not allowed within the inputs 3 0 10 V 0 20 mA can be connected optionally ngineering Inc 230...

Страница 21: ...rdous Location CSA 213 Hazardous Location APPROVED for use in Class I Division 2 Group A B C D Tx Class I Zone 2 Group IIC Tx FM Approval Factory Mutual Research FM to Approval Standard Class Number 3611 3600 3810 APPROVED for use in Class I Division 2 Group A B C D Tx Class I Zone 2 Group IIC Tx Note You will find current approvals on the rating plate of the rel evant module ngineering Inc 230 Ry...

Страница 22: ... their low pollutant equipment Contact a certified electronic waste disposal center for environmentally acceptable recycling and disposal of your old devices Warning Risk of personal injury and material damage In potentially explosive atmospheres there is a risk of personal in jury or damage to material if you disconnect connectors when the system is in RUN In potentially explosive atmospheres alw...

Страница 23: ...re the IDEC SmartRelay with cable conductor cross sections from 1 5 mm2 to 2 5 mm2 see Chapter 2 3 Do not exceed the screw torque of the terminals The maximum torque is 0 5Nm see Chapter 2 3 Keep the cabling as short as possible If longer cables are necessary you should use shielded versions You should always route your cables in pairs i e one neutral conduc tor plus one phase conductor or signal ...

Страница 24: ...y is designed for fixed and enclosed instal lation in the housing or the control cabinet Safety of electronic control equipment Introduction The notes below apply regardless of the type or manufactur er of the electronic control Warning Open facilities Death serious bodily injury or considerable damage to property can occur Modules of an IDEC SmartRelay are open facilities This means you must inst...

Страница 25: ...d ambient tempera ture over a period of several days Careful computer controlled final testing Statistical evaluation of all returned systems and compo nents to enable the immediate initiation of suitable cor rective measures Monitoring of major control components using online tests cyclic interrupt for the CPU etc These measures are referred to as basic measures Carrying out tests You must howeve...

Страница 26: ...ectronic control equipment with a safety function the measures that have to be taken to prevent or rectify faults are based on the risks involved in the installation As of a cer tain degree of hazard the basic measures mentioned above are no longer sufficient Additional measures must be imple mented and approved for the controller Important information The instructions in the operating manual must...

Страница 27: ... digital inputs I7 I8 Maximum setup of a IDEC SmartRelay without analog inputs FL1D H12RCA FL1D B12RCA and FL1D H12RCC FL1D B12RCC IDEC SmartRelay Base 4 digital modules and 4 analog modules example I1 I8 IDEC SmartRelay Base Q1 Q4 I9 I12 FL1B M08 Q5 Q8 I13 I16 FL1B M08 Q9 Q12 I17 I20 FL1B M08 Q13 Q16 I21 I24 FL1B M08 AI1 AI2 FL1B J2B2 AI3 AI4 FL1B J2B2 AI5 AI6 FL1B J2B2 AI7 AI8 FL1B J2B2 In addit...

Страница 28: ...classes When setting up expansion modules of different power volt ages take the following restrictions into consideration Note To power the CPU module and expansion I O modules use one power supply to supply the same power voltage When using different power supplies the fast transient burst immunity IEC61000 4 4 will be 1 kV power supply A 100 to 240V AC DC module cannot be connected to the right ...

Страница 29: ... cor responds with 4 subunits IDEC SmartRelay expansion modules have a width of 36 mm which corresponds with 2 subunits Note The figure below shows you an example of the installation and removal of a FL1D H12RCC and a digital module The measures shown apply to all other IDEC SmartRelay Base versions and expansion modules Warning Always switch off power before you remove and insert a module base mo...

Страница 30: ...ap it on The mount ing interlock at the rear must engage IDEC SmartRelay digital module 3 On the right side of the IDEC SmartRelay Base IDEC SmartRelay expansion module remove the connector cap 4 Place the digital module onto the DIN rail on the right hand side of the IDEC SmartRelay Base 5 Slide the digital module towards the left until it contacts the IDEC SmartRelay Base 1 2 3 4 5 6 ngineering ...

Страница 31: ...left In its end position the slide interlock engages in the IDEC SmartRelay Base Repeat steps 3 through 6 to mount further expansion mod ules Note The expansion interface on the last expansion module must be covered ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 32: ...installed only one IDEC SmartRelay Base Part A 1 Insert a screwdriver into the eyelet at the bottom of the slide interlock and move the latch downward 2 Swing the IDEC SmartRelay Base off the DIN rail 1 2 1 2 3 4 A B ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 33: ...elet at the bottom of the slide interlock and lever it downward 4 Swing the expansion module off the profile rail Repeat steps 1 to 4 for all other expansion modules Note If you have connected more than one expansion module it is advis able to start removal with the last module at the right hand side Make sure that the slide interlock of the module to be installed re moved is not engaged in the ne...

Страница 34: ...e the mounting slides on the rear side of the devices towards the outside You can now wall mount the IDEC SmartRelay by means of two mounting slides and two φ M4 screws tightening torque 0 8 to 1 2Nm Mounting slides ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 35: ...Relay you need to drill holes using the template shown below 53 5 0 2 35 5 0 2 n x 35 5 0 2 98 0 3 1 2 2 2 All dimensions in mm Bore hole for φ M4 screw Tightening torque 0 8 to 1 2 Nm 1 IDEC SmartRelay Base 2 IDEC SmartRelay expansion module ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 36: ... adequately from impermissible contact to live parts local standards must be complied with Cross section mm2 AWG Phoenix Contact Ferrule type No NIC HIFU Blade Terminals type No NIC HIFU Insulated Pin Terminals type No 0 3 22 AI0 5 10WH BT1 25 10 1 0 5 20 AI0 5 10WH TGN TC 1 25 11T 0 75 18 AI0 75 8GY 1 25 18 AI1 5 8BK BT1 25 10 1 BT2 9 1 2 0 16 AI2 5 8BU BT2 9 1 Recommended crimping tool CRIMPFOX ...

Страница 37: ...martRelays FL1D 12RCE FL1B M08B2R2 are suitable for a supply voltage of 12 V AC DC or 24 V AC DC Note the information on connection in the product informa tion document shipped with your device and the technical specifications in Appendix A relating to permissible voltage tolerances line frequency and current consumption Note A power failure may cause an additional edge triggering signal at the sp...

Страница 38: ... least 20 above the rated voltage IDEC SmartRelay with DC power supply IDEC SmartRelay with AC power supply Note IDEC SmartRelay is a double insulated switchgear You do not need to connect an equipment grounding conductor Circuit protection with AC voltage To suppress voltage peaks on the power supply lines you can install a metal oxide varistor MOV Make sure that the operating voltage of the vari...

Страница 39: ... 1 to 4 specifications For identifying the version see page 4 I1 I6 I7 I8 I1 I6 I7 I8 Signal status 0 5 VDC 5 VDC 5 VDC 5 VDC Input current 0 85 mA 1 0 05 mA 0 85 mA 3 0 05 mA Signal status 1 8 5 V DC 2 8 5 V DC 12 V DC 4 12 V DC Input current 1 5 mA 0 1 mA 2 mA 5 0 15 mA FL1D H12RCA FL1D B12RCA AC FL1B M08 D2R2 AC FL1D H12RCA FL1D B12RCA DC FL1B M08 D2R2 DC FL1D H12RCC FL1D B12RCC AC FL1B M08 C2R...

Страница 40: ...you connect a switch with a glow lamp to IDEC SmartRelay The current that flows through the glow lamp allows IDEC SmartRelay to detect a 1 signal even though the switch contact is not closed If however you use a switch the glow lamp of which is fitted with a power supply this response does not occur L1 N N L1 C Take into account the quiescent current of any 2 wire prox imity switches used into acc...

Страница 41: ... disconnects You must choose the voltage level for which the capacitor is rated such that it is not destroyed in the case of overvoltage At 230 V AC the voltage between N and an input I n must not be greater than 40 V to guarantee a 0 signal You can connect approximately ten glow lamps to the capacitor ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www...

Страница 42: ...o not apply to these high speed in puts Note The high speed inputs I5 and I6 are the same as in the previous versions FL1A to FL1C i e a circuit program that is written in these versions can be transferred to the new FL1D units by means of the programming software WindLGC without any changes to these features Expansion modules do not have high speed inputs Analog inputs I7 and I8 The inputs I7 and...

Страница 43: ...otentiometer and 10 V input voltage as the maximum value you must ensure that with a connected in put voltage of 24 V 14 V must release via the series resistor so that a maximum of 10 V are supplied when you turn the potentiometer one full rotation With a voltage of 12 V this can be neglected Note The FL1B J2B2 expansion module provides additional analog in puts Always use twisted and shielded cab...

Страница 44: ...a digital module L M M L I1 I2 I3 I4 I5 I8 The inputs of these devices are not isolated and therefore require a common reference potential chassis ground With FL1D H12RCE FL1D B12RCE and FL1D H12SND modules you can tap analog signals between the supply voltage and chassis ground series resistor with 24 V DC L1 N L3 L2 N L1 I1 I2 I3 I4 I5 I6 The inputs of these devices are arranged in 2 groups each...

Страница 45: ...0 20 mA cur rent measurement of the FL1B J2B2 module 2 Connect the plus connector on the sensor to the 24 V supply voltage L Connect the ground connection on the sensor to the corre sponding M input M1 or M2 on the FL1B J2B2 module M L L M U1 I2 M2 U2 I1 M1 PE L M 1 2 3 RUN STOP M M L PE PE terminal for connecting earth and the shielding of the analog measuring cable 1 Earth 2 Cable shielding 3 DI...

Страница 46: ... FL1D H12RCC FL1D B12RCC FL1B M08C2R2 I1 I8 N 100nF 390kΩ 390kΩ 62kΩ AC 2 wire Sensor I1 to I8 R4 100 to 240 V AC N L1 Internal Circuit Digital AC DC Input When using the AC two wire sensor ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 47: ...D B12RCA FL1B M08D2R2 I1 I8 4 3kΩ 5V 510Ω 100nF P2 AC 2 wire Sensor I1 to I8 R3 240 V AC P1 P2 Internal Circuit Internal Circuit Digital AC DC Input When using the AC two wire sensor ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 48: ...1D B12RCE FL1D H12SND FL1B J2B2 FL1B J2B2 I1 I8 3 6kΩ 2 2kΩ 100nF M Internal Circuit Digital DC Input I7 I8 U1 U2 M M1 M2 39kΩ 5V 39kΩ 10nF Internal Circuit Analog Input 0 10V Max 125Ω 125Ω 10nF I1 I2 M1 M2 Internal Circuit Analog Input 0 20mA ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 49: ...uctuating analog values when using these expansion modules proceed as follows Use only shielded encoder wires Shorten the encoder wire as much as possible The encoder wire must not be more than 10 meters long Clamp the encoder wire on one side only and clamp it only to the PE terminal on the FL1B J2B2 FL1D K2B2 expansion mod ule Connect ground on the encoder supply to the PE terminal on the expans...

Страница 50: ...utputs You can connect various loads to the outputs e g lamps flu orescent lamps motors contactor relays etc For informa tion on the properties required for the loads connected to the these units refer to Appendix A Connecting This is how you connect the load 1 2 Q1 Q2 1 2 Q5 Q6 1 2 1 2 load load Protection with automatic circuit breaker max 16 A characteristics B16 e g Power circuit breaker 5SX2 ...

Страница 51: ...liary load voltage supply is not necessary because IDEC SmartRelay supplies the load voltage Requirements for transistor outputs The load connected to IDEC SmartRelay must have the fol lowing characteristics The maximum switched current is 0 3 A per output Connecting This is how you connect the load to a IDEC SmartRelay with transistor outputs Q1 Q2 M M Q5 Q6 M M load Load 24 V DC 0 3 A max load n...

Страница 52: ...martRelay Manual 42 FL1D K2B2 V1 V2 RUN STOP M2 M1 L M L M L M OUTPUT 2x 0 10V PE 0 10V 0 10V 2 1 R R 1 Earth 2 DIN rail V1 V2 0 10 V DC R min 5 kΩ ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 53: ...L1B M08D2R2 Relay Output FL1D H12SND FL1B M08B1S2 Transister Output Source FL1D K2B2 Analog Output 0 10V 27kΩ 47kΩ 24V 2 1 Q1 Q4 Internal Circuit Internal Circuit 24V 10kΩ 10nF 10nF M Q1 Q4 Internal Circuit Internal Circuit 10Ω 100nF 24V Internal Circuit 4 7kΩ Internal Circuit V1 V2 M1 M2 ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 54: ...nected beforehand This is necessary for safety reasons ADDR RUN STOP AS I AS I Networking on the AS interface bus To make the connection to the AS interface bus you need a communications capable IDEC SmartRelay variant IDEC SmartRelay base module FL1B CAS2 an AS interface power supply and an AS interface master IDEC SmartRelay can only be accepted as a slave on the AS interface bus This means that...

Страница 55: ...ress space If you are al ready using more than 12 physical outputs or more than 20 physical inputs it is no longer possible to operate the FL1B CAS2 Warning The AS Interface and IDEC SmartRelay systems must never be connected together electrically Use safe isolation acc to IEC 61131 2 EN 50178 UL 508 CSA C22 2 No 142 IDEC SmartRelay system AS Interface system Inputs Output data bits In D0 In 1 D1 ...

Страница 56: ...perly Is the power supply connected to the expansion module In addition always ensure that you switch on the power supply to the expansion module first before activating the power supply to the IDEC SmartRelay base module or activate both power supplies at the same time if you do not do this the system does not detect the expansion module when you start up the IDEC SmartRelay base module Note Afte...

Страница 57: ...sion 1 to 3 FL1B J2B2 Version 1 to 4 FL1D K2B2 Version 1 For identifying the version see page 4 10sec Power Input signals at base and expansion I O modules Base module input and output signals Run Expansion I O module input and output signals are accepted During the initialization period are accepted of expansion I O modules During the initialization period of expansion I O modules inputs and outp...

Страница 58: ...f After power on No program in memory or empty with program IDEC SmartRelay in RUN mode or empty with program or empty with program Program in memory With stored program from IDEC SmartRelay IDEC SmartRelay in RUN mode with a program copied from the memory cartridge card in IDEC SmartRelay With stored program from IDEC SmartRelay with a program copied from the memory cartridge card in IDEC SmartRe...

Страница 59: ...card IDEC SmartRelay adopts the operational state it had prior to POWER OFF Versions without display unit FL1D B12 automatically change from STOP to RUN LED changes from red to green 4 If you have enabled retentivity at least for one function or a function is permanently retentive the current values are retained at POWER OFF Note When a power failure occurs while you are entering a circuit pro gra...

Страница 60: ...ode not FL1D B12 LED is red only FL1D B12 Display Screen mask for monitoring I Os and messag es after START in the main menu not FL1D B12 Switching IDEC SmartRelay to parameter assignment mode not FL1D B12 LED is green only FL1D B12 Action of IDEC SmartRelay The inputs data is not read The circuit program is not ex ecuted The relay contacts are per manently open or the transis tor outputs are swit...

Страница 61: ...on modules which are arranged to the right of the FL1B CAS2 expansion module is interrupted Recommendation Position FL1B CAS2 on the far right hand side If communication is interrupted the switching outputs are reset after about 40 to 100 ms LED is lit Green RUN Red STOP Orange The expansion mod ule communicates with the device to its left The expansion mod ule does not com municate with the devic...

Страница 62: ...in this manual relate only to the creation of circuit programs on the actual IDEC SmartRelay because the programming software WindLGC already con tains an extensive Online Help See also Chapter 7 Note IDEC SmartRelay versions without display unit i e the FL1D B12RCE FL1D B12RCA and FL1D B12RCC units do not have an operator panel and display unit They are primarily designed for use in small machine...

Страница 63: ... next step we shall create a circuit program based on a simple conventional circuit which you can enter directly in IDEC SmartRelay in the third step It will take you only a few pages of this manual store your first executable circuit program in the IDEC SmartRelay unit With a suitable hardware switches etc you will then be able to carry out first tests ngineering Inc 230 Ryan Way South San Franci...

Страница 64: ...es FL1B J2B2 has the inputs at the bottom Each output is identified by the letter Q plus a number FL1D K2B2 AQ plus number In the figure you can see the output terminals at the bottom L M I13I14I15I16 Q11 Q9 Q12 Q10 RUN STOP L M A 3 RUN STOP L M I1 I2 I3 I4 I5 I6 Q1 Q2 Q3 Q4 AI1 AI2 L M I9 I10I11I12 Q7 Q5 Q8 Q6 RUN STOP M3U3AI4M4U4 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 PE INPUT 2x 10 V 2...

Страница 65: ...gnal is digital signals at AI1 or AI2 are analog IDEC SmartRelay s connectors The term connector refers to all connections and states in IDEC SmartRelay The digital I O status can be 0 or 1 Status 0 means that the input does not carry a voltage Status 1 means that the input carries voltage The hi lo and x connectors have been introduced to make it easier for you to create the circuit program hi hi...

Страница 66: ...uts FL1D H12RCC FL1D B12RCC FL1D H12RCA FL1D B12RCA Two groups I1 I4 and I5 I8 I9 I24 AI1 AI8 none FL1D H12RCE FL1D B12RCE FL1D H12SND I1 I6 I7 I8 AI1 AI2 I9 I24 AI3 AI8 Outputs Q1 Q4 Q5 Q16 none AQ1 AQ2 lo Logical 0 signals off hi Logical 1 signals on x An existing connection that is not used ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 67: ...nal box When you create the circuit program you interconnect the blocks To do so simply select the connection you require from the Co menu The menu name Co is an abbreviation of the term Connector Logic operations The most elementary blocks are the logic operations AND OR I1 I2 x 1 Q x Inputs I1 and I2 are here connected to the OR block The last two inputs of the block remain unused and are iden t...

Страница 68: ...put This connector is not required Block Output Block number as signed by IDEC SmartRelay Assigning a block number IDEC SmartRelay assigns each new block a circuit program a block number IDEC SmartRelay uses these block numbers to indicate the block interconnections This means that these numbers are mainly an aid to your orientation in the circuit program I1 I2 I3 1 B1 B2 B2 1 B3 Q1 B1 B1 I4 I5 I6...

Страница 69: ...r circuit layout To do so however you need to know how IDEC SmartRelay has named the blocks Note We advise you to create an organizational program chart You will find this a valuable aid when you create the circuit program because you can enter in this chart all block numbers that IDEC SmartRelay assigns By using the WindLGC software to program IDEC SmartRelay you can directly create a function ch...

Страница 70: ...d on and off by means of the switches S1 OR S2 AND S3 Relay K1 picks up when the condition S1 OR S2 AND S3 is met K1 S1 K1 S2 E1 S3 Creating this circuit with IDEC SmartRelay In IDEC SmartRelay you create a circuit logic by intercon necting blocks and connectors S1 S3 I3 x Q1 1 I1 I2 x L 1 N Wiring of the inputs Circuit program in IDEC SmartRelay Wiring of the outputs ngineering Inc 230 Ryan Way S...

Страница 71: ...open contact S3 is interconnected in series to output Q1 and to a further circuit element A series connection corresponds with the AND block I3 x Q1 Step 2 S1 and S2 are connected in parallel A parallel circuit corresponds with the OR block I3 x Q1 1 I1 I2 x Unused inputs The circuit program automatically assigns the unused con nectors a status that ensures proper functioning of the rele vant bloc...

Страница 72: ...Relay S3 to connector I3 of IDEC SmartRelay The output of the AND block controls the relay at output Q1 The load E1 is connected to output Q1 Wiring example The following figure shows you the wiring based on the FL1D H12RCC B12RCC L1 N S 3 S 2 S 1 L1 N N L1 I1 I2 I3 I4 1 2 Q1 Input wiring Output wiring Load ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 418...

Страница 73: ...tart command on the main menu to set RUN mode When the system is in RUN you can return to parameter assignment mode by pressing the ESC key When parameter assignment mode is open and you want to return to programming mode select the Stop command from the parameter assignment menu and confirm Stop Prg prompt with Yes To do so move the cursor to Yes and confirm with OK For more details on operating ...

Страница 74: ...o exit programming mode You select a connector block when the cursor appears as solid square Press or to select a connector or a block Confirm with OK Press ESC to return to the previous step Rule 4 Planning Before you start to create a circuit program you should either first create design on paper or program IDEC SmartRelay directly using WindLGC IDEC SmartRelay can only save complete and faultle...

Страница 75: ...ese menus refer to Appendix D Program Card Setup Start Edit Clear Prg Password Card Card CopyProtect IDEC SmartRelay Clock Contrast OK OK OK ESC ESC ESC Main menu Programming menu Transfer menu Setup menu Parameter assignment menu Stop Set Param Set Prg Name ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 76: ...and switched it on The display now shows you the message Switch IDEC SmartRelay to programming mode by pressing ESC This will take you to the main menu of IDEC SmartRelay IDEC SmartRelay s main menu The first character in the first line is the cursor Press and to move the cursor up and down Move it to Pro gram and confirm with OK IDEC SmartRelay opens the programming menu IDEC SmartRelay s program...

Страница 77: ...y You are now in programming mode Press and to select the other outputs Now start to edit your circuit program Note Because we have not yet saved a password for the circuit program in IDEC SmartRelay you can directly enter editing mode When you select Edit after you have saved a password protected circuit program you are prompted to enter a password and to confirm it with OK You can only edit the ...

Страница 78: ...lay interprets this parallel circuit as an OR logic because S1 OR S2 switches on the output Translated into a IDEC SmartRelay circuit program this means Relay K1 is at output Q1 is controlled by means of an OR block Circuit program S1 is connected to the I1 and S2 to the I2 input connector of the OR block The corresponding layout of the circuit program in IDEC SmartRelay I1 I2 x Q1 1 ngineering In...

Страница 79: ...switches input I1 while S2 switches input I2 The load is connected to the relay Q1 3 6 3 Circuit program input Let us now write the circuit program starting at the output and working towards the input IDEC SmartRelay initially shows the output Q1 The first IDEC SmartRelay output ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 80: ...iting mode Q1 Co The cursor is displayed as a solid square You can now select a con nector or a block The cursor no longer appears in the form of an underscore but instead as a flashing solid square IDEC SmartRelay of fers you various options here Select GF basic functions by pressing the key until GF appears and confirm with OK IDEC SmartRelay now shows the first block from the list of basic func...

Страница 81: ...e display now shows Block number Your complete circuit program layout You have now entered the first block Each new block is au tomatically assigned a block number The only thing left to do is interconnect the block inputs This is how it is done Press OK 1 B1 Q1 Co The display now shows Select the Co list Press OK 1 B1 Q1 x The display now shows ngineering Inc 230 Ryan Way South San Francisco CA 9...

Страница 82: ...r jumps to the next input of the OR block 1 B1 Q1 1 Q1 I1 I1 B1 Your complete circuit program in IDEC SmartRelay up to now The display now shows Now you connect input I2 to the input of the OR block You already know how to do this 1 Switch to editing mode Press OK 2 To select the Co list Press or 3 To confirm the Co list with Press OK 4 To select I2 Press or 5 To apply I2 Press OK 1 Q1 I1 B1 ngine...

Страница 83: ...s of the OR block for this circuit program You can mark the unused inputs with an x Enter the x character twice 1 Switch to editing mode Press OK 2 To select the Co list Press or 3 To accept the Co list Press OK 4 To select x Press or 5 To apply x Press OK 1 Q1 I1 B1 I2 Q1 B1 x The display now shows This is the layout of your circuit program ngineering Inc 230 Ryan Way South San Francisco CA 94080...

Страница 84: ...or to the relevant position e g Confirm with OK Now press or to invert this input Next press ESC You can review your first circuit program by pressing or to move the cursor through the circuit program We shall now exit circuit programming mode This is how it is done Return to the programming menu Press ESC 1 B1 Q1 I2 I3 x I1 1 B1 Q1 I2 I3 1 Q1 I2 B1 I3 x x I1 I1 The display now shows Your circuit ...

Страница 85: ... of up to 16 uppercase lowercase letters numbers and special characters In the programming menu 1 To move the cursor to Edit Press or 2 To accept Edit Press OK 3 Move the cursor to Edit Name Press or 4 To accept Edit Name Press OK Press and to list the alphabet from A a to Z z num bers and special characters either in ascending or descend ing order You can select any letter number or character To ...

Страница 86: ...r assignment mode 3 6 5 Password You can protect a circuit program from unauthorized access by assigning it a password To assign a password A password may have a maximum length of 10 characters and consists only of uppercase letters A to Z On IDEC SmartRelay the password can be assigned edited or deac tivated only in the Password menu In the programming menu 1 Move the cursor to Password Press or ...

Страница 87: ... same as for entering the name of the circuit program Select New and enter 3 Select A Press 4 To move to the next letter Press 5 Select A Press The display now shows Old No Password New AA 6 To confirm the password Press OK Your circuit program is now protected with the password AA and you are returned to the programming menu ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General In...

Страница 88: ...cted memory cartridge card you first need to assign a password to this new program see Chapter 6 1 Changing the Password You need to know the current password in order to change it In the programming menu 1 Move the cursor to Password Press or 2 To confirm the Password Press OK Select Old and enter your old password in our case AA by repeating steps 3 through 6 as described earlier The display now...

Страница 89: ... You must know your current password in our example ZZ same as if you were chang ing it In the programming menu 1 Move the cursor to Password Press or 2 To confirm the Password Press OK Select Old and enter your current password as described in steps 3 to 5 Confirm your entries with OK The display shows Old ZZ New Clear the password by leaving the input box blank 3 To confirm the blank password Pr...

Страница 90: ... to accelerate progress in our further exercises and examples Password Wrong Password When the user inputs the wrong password and confirms the input with OK IDEC SmartRelay does not open editing mode but returns to the programming menu This repeats it self over and again until you input the correct password ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 418...

Страница 91: ...56789 1 0123456789 2 01234 Q 0 123456789 1 0123456 AI 1 00000 2 01000 3 00253 AI 4 00010 5 00000 6 00005 Display field of the IDEC SmartRelay in RUN mode Start screen Date and current time of day only for versions with realtime clock This element flashes if the date and time are not set Inputs I1 to I9 Inputs I10 to I19 Inputs I20 to I24 Outputs Q1 to Q9 Outputs Q10 to Q16 Analog inputs AI1 to AI3...

Страница 92: ...0 AQ 1 00000 2 01000 Analog inputs AI7 to AI8 Markers M1 to M9 Markers M10 to M19 Markers M20 to M24 4 cursor keys for manual intervention in the circuit program ESC key Press Press Press Analog outputs AQ1 to AQ2 ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 93: ... 2 01234 Input output status is 1 inverted Input output status is 0 not inverted In this example only the inputs I1 I15 Q8 and Q12 are set high Status indication on the display I 0 123456789 1 0123456789 2 01234 L1 N S1 S2 1 I1 I2 Q1 Q 0 123456789 1 0123456 Let us examine this using our ex ample When switch S1 is closed the status at input I1 is hi IDEC SmartRelaycomputes the output states by mean...

Страница 94: ...e the first circuit program as a basis for the sec ond with some slight modifications First of all take a look at the circuit diagram for the second circuit program L1 N S1 S2 K1 K1 E1 You already know the first part of the circuit S1 and S2 switch a relay which is to be used to switch on the load E1 and to switch off the load with a delay of 12 minutes This is the circuit program layout in IDEC S...

Страница 95: ...in menu select Program 3 On the Programming menu select Edit confirm with OK Next select Edit Prg and confirm with OK If required enter your password at the prompt and con firm with OK You can now modify the current circuit program Adding a block to a circuit program Move the cursor to the B in B1 B1 is the number of the OR block Q1 B1 To move the cursor Press We now insert the new block at this p...

Страница 96: ...lock is assigned the block number B2 The cursor is positioned at the top input of the added block The B1 block previously connected to Q1 is automatically connected to the uppermost input of the new block Note that you can only interconnect digital inputs with digital outputs or analog inputs with analog outputs The old block will other wise be lost The off delay block has three inputs At the top ...

Страница 97: ...witch to editing mode Press OK IDEC SmartRelay shows the parameters in the parameter assignment window B2 R T 00 00s T The block pa rameter B2 is a time function means The parameter is shown and can be modified in the parameter assignment mode R means Retentivity is en abled for this block Time value Timebase To change the time value Press and to position the cursor Press and to modify the value a...

Страница 98: ...ter assignment mode 1 Move the cursor to the protection mode Press or 2 Select the protection mode Press or The display should now show T 12 00m B2 R T 12 00m B2 R or Protection mode The value of the time T can be modified in parameter assign ment mode Protection mode The value of the time T is hid den in parameter assignment mode 3 Confirm your entries with OK Enabling disabling retentivity To de...

Страница 99: ...y in programming mode i e this is not possible in parameter assign ment mode In this manual the protection mode or and retentivity R or settings are only shown in the displays where these can ac tually be changed Verification of the circuit program This program branch for Q1 is now completed IDEC SmartRelay shows you the output Q1 You can once again view the circuit program on the display Use the ...

Страница 100: ...is a reminder 1 To return to the programming menu Press ESC 2 To return to the main menu Press ESC 3 To move the cursor to Start Press or 4 To confirm Start Press OK IDEC SmartRelay is back in RUN mode 2005 01 27 Mo 09 30 You can press or to scroll the pag es and to monitor the I O states ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 101: ...uired enter your password and confirm with OK 4 Select Edit Prg Press or 5 Confirm Edit Prg Press OK 6 To move the cursor to the input of Q1 i e to B2 press 7 Confirm with OK 8 Now replace block B2 with block B1 at output Q1 The procedure Select the BN list Press or Accept the BN list Press OK Select B1 Press or Apply B1 Press OK Result Block B2 is deleted because it is no longer used in the circu...

Страница 102: ...ress OK if required enter your password and confirm with OK 4 To select Edit Prg Press or 5 To confirm Edit Prg Press OK 6 To move the cursor to the input of Q1 i e to B2 press 7 Confirm with OK 8 Now set the connector x at output Q1 instead of block B2 To do so Select the Co list Press or Accept the Co list Press OK Select x Press or Apply x Press OK Result Block B2 is deleted because it is no lo...

Страница 103: ...g output values for RUN STOP transition You can select the analog values that are output at the two analog outputs when IDEC SmartRelay changes from RUN mode to STOP mode In the programming menu 1 Move the cursor to Edit Press or 2 To accept Edit Press OK 3 Move the cursor to AQ in Stop Press or 4 To accept AQ in Stop Press OK IDEC SmartRelay shows the following display Defined Last AQ in Stop Las...

Страница 104: ...ing a specific analog output value You want to output a specific analog value at the two analog outputs 1 Move the cursor to Defined Press or 2 Confirm Defined Press OK The display shows AQ1 00 00 AQ2 00 00 3 Enter a specific output value for each of the two analog outputs 4 To confirm your entry Press OK ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 ...

Страница 105: ...o Program Press OK 3 Move the cursor to Clear Prg Press or 4 Confirm Clear Prg Press OK To cancel deletion of the circuit program leave the cursor at No and press OK Program Card Setup Start IDEC SmartRelay opens the main menu Edit Clear Prg Password IDEC SmartRelay changes to the programming menu Clear Prg No Yes ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 ...

Страница 106: ... assignment mode by calling the Set menu command in programming mode by calling the Setup menu com mand To enable disable automatic S W Time conversion in program ming mode 1 Switch IDEC SmartRelay to programming mode 2 You are now in the main menu and want to select the Setup menu command Press or 3 Confirm Setup Press OK 4 Move the cursor to Clock Press or 5 Confirm Clock Press OK 6 Move the cur...

Страница 107: ... Set then menus Clock and S W Time You can now enable disable automatic S W Time conversion Enabling summertime wintertime conversion You now want to enable this conversion and define or set its parameters 1 Move the cursor to On Press or 2 Confirm On Press OK The display shows EU 3 Select the desired conversion Press or What is shown on the display EU represents the start and end of European summ...

Страница 108: ...02 00 01 00 60 Min AUS Last Sunday in October 02 00 03 00 Last Sunday in March 03 00 02 00 60 Min AUS TAS First Sunday in October 02 00 03 00 Last Sunday in March 03 00 02 00 60 Min NZ First Sunday in October 02 00 03 00 Third Sunday in March 03 00 02 00 60 Min Customizing the month and the day 02 00 02 00 Time zone difference Customizing the month and the day 03 00 03 00 Time zone difference User...

Страница 109: ...r 3 Confirm the menu item PressOK The display shows MM DD 01 01 01 01 000min 0 Cursor solid square Month MM and Day DD Start of summertime End of summertime The desired time zone difference in min Let us assume you want to configure the following parame ters Start of summertime 31st of March end of summer time 1st of November time difference of 120 minutes This is how you can enter your data Press...

Страница 110: ... SmartRelay indicates that summertime wintertime conversion is enabled and that user defined parameters have been set Note To disable summertime wintertime conversion in this menu you merely confirm Off with OK Note Summertime wintertime conversion only functions when IDEC SmartRelay is operating in RUN or STOP status It does not func tion when IDEC SmartRelay is in buffered operation see Chapter ...

Страница 111: ...ng of the automatic synchronization function is displayed in the bottom row The default setting is Off disabled Enabling synchronization You want to enable synchronization 1 Move the cursor to On Press or 2 Confirm On Press OK IDEC SmartRelay shows the following display On Off Sync On When synchronization is enabled IDEC SmartRelay trans mits the time of day to the expansion modules once daily af ...

Страница 112: ...n is based on the maximum number of bytes a circuit program may contain The total number of bytes used can be determined by adding up the num ber of bytes used for the relevant function blocks Retentive memory Rem In this area IDEC SmartRelay stores process variables which need to be retentive e g the Operating hours counter value Blocks with optional retentivity use this memory area only if this ...

Страница 113: ...f and on the timer current value of the On delay FB is sometimes reset as shown in Fig 2 Other FBs are shown below Function blocks whose timer current value is sometimes reset Off delay On delay On Off delay Retentive on delay Inter val time delay relay Pulse output Edge triggered interval time delay relay Operating hours counter Asynchronous pulse gen erator Stairwell Light Switch Dual function s...

Страница 114: ...s Blocks REM 2000 130 60 Function Program memory Rem memory 1 Basic functions AND 12 AND with Edge Detection 12 NAND not AND 12 NAND with Edge Detection 12 OR 12 NOR not OR 12 XOR exclusive OR 8 NOT Negation 4 Special functions Times On delay 8 3 Off delay 12 3 On Off delay 12 3 Retentive on delay 12 3 Interval time delay relay Pulse output 8 3 Edge triggered interval time delay relay 16 4 Asynchr...

Страница 115: ...ory space is fully occupied optimize your circuit pro gram or install a second IDEC SmartRelay Counter Up down counter 24 5 Operating hours counter 24 9 Frequency trigger 16 Analog Analog trigger 16 Analog differential trigger 16 Analog comparator 24 Analog value monitoring 20 Analog amplifier 12 Analog multiplexer 20 Analog Ramp Control 36 PI controller 40 2 Others Latching relay 8 1 Current impu...

Страница 116: ... Function Memory area Bytes Blocks REM B1 OR 12 1 B2 AND 12 1 B3 Seven day time switch 20 1 B4 On delay 1 1 Configured with retentivity 8 1 3 B5 Stairwell Light Switch 12 1 0 B6 AND 12 1 Resources used by the circuit program 76 6 3 Memory space limits in IDEC SmartRelay 2000 130 60 Still available in IDEC SmartRelay 1924 124 57 Q1 x I2 B1 B2 B3 x B4 20 No 1 No 2 No 3 I1 Par B5 B6 Par Q2 I3 I4 x RE...

Страница 117: ...oceed as follows 1 Switch the IDEC SmartRelay to programming mode as a reminder refer to page 63 2 Select Edit Press or 3 Accept Edit Press OK 4 Select Memory Press or 5 Accept Memory Press OK The display now shows Free Memory Byte 1924 Block 124 Rem 57 ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 118: ...ts show the elements available in IDEC SmartRelay Usually this includes all connectors basic functions and special functions the IDEC SmartRelay knows This includes all the blocks you have created in IDEC SmartRelay by the time you call the BN list If not all is shown IDEC SmartRelay does not show all elements if No further blocks may be added This is either an indication of insufficient memory sp...

Страница 119: ...SND FL1D H12RCE and FL1D B12RCE are equipped with the inputs I7 and I8 which can also be programmed for use as AI1 and AI2 inputs Signals at the I7 and I8 inputs are interpreted as digital values and those at the AI1 and AI2 inputs are inter preted as analog values The inputs of a connected analog module are numbered according to the already existing an alog inputs Special functions the inputs of ...

Страница 120: ...ficance to a circuit program 2 Analog outputs Analog outputs are identified by the letters AQ Two analog outputs are available namely AQ1 and AQ2 An analog out put can only be connected with the analog input of a function an analog memory marker AM or an analog output connector L M I13I14I15I16 Q11 Q9 Q12 Q10 RUN STOP L M A 3 RUN STOP L M I1 I2 I3 I4 I5 I6 Q1 Q2 Q3 Q4 AI1 AI2 L M I9 I10I11I12 Q7 Q...

Страница 121: ...e circuit pro gram The content of shift register bits can only be modified by means of the Shift register special function see Chapter 4 4 25 Cursor keys Up to four cursor keys are available to you namely C C C and C C Cursor Cursor keys are pro grammed for the circuit program in the same ways as other inputs You can set the cursor keys in the corresponding dis play while the system is in RUN see ...

Страница 122: ...g example is found in Chapter 3 6 3 The GF list contains the basic function blocks you can use for your circuit program The following basic functions are available View in the circuit diagram View in IDEC SmartRelay Name of the basic function Series circuit with normally open con tact AND see page 114 AND with Edge Detec tion see page 115 Parallel circuit with normally closed con tact NAND not AND...

Страница 123: ...ally closed con tact NOR not OR see page 119 Double changeover contact XOR exclusive OR see page 120 Normally closed contact NOT negation inverter see page 120 View in the circuit diagram View in IDEC SmartRelay Name of the basic function ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 124: ... is only 1 if all inputs are 1 i e all con tacts are closed At an unused block input x x 1 Table of the AND logic 1 2 3 4 Q 0 0 0 0 0 0 0 0 1 0 0 0 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 0 1 0 0 1 1 0 0 0 1 1 1 0 1 0 0 0 0 1 0 0 1 0 1 0 1 0 0 1 0 1 1 0 1 1 0 0 0 1 1 0 1 0 1 1 1 0 0 1 1 1 1 1 ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 125: ... an edge triggered AND is only 1 if all inputs are 1 and if at least one input was low in the previous cycle At an unused block input x x 1 Timing diagram for the AND with Edge Detection 1 3 Q 2 1 2 3 4 5 6 7 8 9 10 4 Cycle ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 126: ...ND is only 0 if the status at all inputs is 1 i e the contacts are closed At an unused block input x x 1 Table of the NAND logic 1 2 3 4 Q 0 0 0 0 1 0 0 0 1 1 0 0 1 0 1 0 0 1 1 1 0 1 0 0 1 0 1 0 1 1 0 1 1 0 1 0 1 1 1 1 1 0 0 0 1 1 0 0 1 1 1 0 1 0 1 1 0 1 1 1 1 1 0 0 1 1 1 0 1 1 1 1 1 0 1 1 1 1 1 0 ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 127: ... the NAND with Edge Detection is only 1 if at least one input is 0 and if all inputs were 1 in the previ ous cycle At an unused block input x x 1 Timing diagram for the NAND with Edge Detection 1 3 Q 2 1 2 3 4 5 6 7 8 9 10 4 Cycle ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 128: ... only 1 if at least one input is 1 i e at least one of the contacts is closed At an unused block input x x 0 Table of the OR logic 1 2 3 4 Q 0 0 0 0 0 0 0 0 1 1 0 0 1 0 1 0 0 1 1 1 0 1 0 0 1 0 1 0 1 1 0 1 1 0 1 0 1 1 1 1 1 0 0 0 1 1 0 0 1 1 1 0 1 0 1 1 0 1 1 1 1 1 0 0 1 1 1 0 1 1 1 1 1 0 1 1 1 1 1 1 ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www st...

Страница 129: ...0 i e if switched off The NOR output is set to 0 when one of the inputs is switched on logical 1 status At an unused block input x x 0 Table of the NOR logic 1 2 3 4 Q 0 0 0 0 1 0 0 0 1 0 0 0 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 0 1 0 0 1 1 0 0 0 1 1 1 0 1 0 0 0 0 1 0 0 1 0 1 0 1 0 0 1 0 1 1 0 1 1 0 0 0 1 1 0 1 0 1 1 1 0 0 1 1 1 1 0 ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General In...

Страница 130: ...ter Symbol in IDEC SmartRelay A normally closed contact in the circuit diagram The output status is 1 if the input is 0 The NOT block inverts the input status Advantage of the NOT block for example The IDEC SmartRelay does not require normally closed contacts You simply use a normally open contact and the NOT block to convert these into a normally closed contact Table of the NOT logic 1 2 Q 0 0 0 ...

Страница 131: ...ontain timer functions retentive functions and various parameter assignment op tions which allow you to adapt the circuit program to suit your own requirements This section provides you with a brief overview of input des ignations and with some particular background information on SFs The SFs in particular are described in Chapter 4 4 ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 G...

Страница 132: ...is input enables a block function When this input is 0 other signal to the block will be ignored Inv Invert A signal at this input inverts the output signal of the block Ral Reset all All internal values are reset Connector X at SF inputs SF inputs connected to connector x are set low That is the inputs carry a lo signal Parameter inputs At some of the inputs you do not apply any signals You con f...

Страница 133: ...rtRelay has a maximum tolerance of 0 02 When 0 02 of the time T is smaller than 0 02 seconds the maximum deviation is 0 02 seconds Example The maximum tolerance per hour 3600 seconds is 0 02 which is proportional to 0 72 seconds The maximum tolerance per minute 60 seconds is 0 02 seconds Accuracy of the timer Seven day Twelve month time switch To prevent timing inaccuracy of the real time clock in...

Страница 134: ...rent data are retained after a power failure and that the block resumes operation at the break point The timer is not reset but resumes operation until the time to go has expired for example To enable this response however the relevant functions must be set retentive Two options are available R The data is retained Current data is not retained default See the example on page 88 SFs Operating hours...

Страница 135: ...into range of values from 0 to 1000 An input voltage exceeding 10V is shown as internal value 1000 Because you can not always process the range of values from 0 to 1000 as predetermined by IDEC SmartRelay you can multiply the digital values by a gain factor and then shift the zero of the range of values offset This allows you to output an analog value to the IDEC SmartRelay display which is propor...

Страница 136: ...chnical data 30 to 70 C 0 to 10 V DC i e 0 to 1000 in IDEC SmartRelay Actual value internal value gain offset thus 30 0 A B i e offset B 30 70 1000 A 30 i e gain A 0 1 Example 2 A pressure sensor converts a pressure of 1000 mbar into a voltage of 0 V and a pressure of 5000 mbar into a voltage of 10 V Actual value internal value gain offset thus 1000 0 A B i e offset B 1000 5000 1000 A 1000 i e gai...

Страница 137: ...1000 mbar 3700 mbar 5000 mbar 0 6 75 10 0 675 1000 4 4 4 1000 1000 1000 1000 3700 5000 0 5 10 0 500 1000 0 01 0 01 0 01 0 0 0 0 5 10 0 5 10 0 500 1000 1 1 1 0 0 0 0 500 1000 0 5 10 0 500 1000 10 10 10 0 0 0 0 5000 10000 0 5 10 0 500 1000 0 01 0 01 0 01 5 5 5 5 10 15 0 5 10 0 500 1000 1 1 1 500 500 500 500 1000 1500 0 5 10 0 500 1000 1 1 1 200 200 200 200 300 800 0 10 0 1000 10 10 10000 10000 10000...

Страница 138: ...nverts into a logical 1 An example of the program code found in Chapter 3 6 3 The table also specifies whether the relevant function can be set retentivity Rem The following SFs are available View in IDEC SmartRelay Name of the special function Rem Times On delay see page 132 REM Off delay see page 136 REM On Off delay see page 138 REM Retentive on delay see page 140 REM Interval time delay relay ...

Страница 139: ...e 147 REM Random generator see page 149 Stairwell Light Switch see page 151 REM Dual function switch see page 154 REM Seven day time switch see page 157 Twelve month time switch see page 162 View in IDEC SmartRelay Name of the special function Rem ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 140: ...er see page 174 Analog Analog trigger see page 177 Analog differential trigger see page 180 Analog comparator see page 184 Analog value monitoring see page 189 Analog amplifier see page 192 View in IDEC SmartRelay Name of the special function Rem Fre ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 141: ...iscellaneous Latching relay see page 195 REM Current impulse relay see page 196 REM Message texts see page 199 Softkey see page 206 REM Shift register see page 210 REM View in IDEC SmartRelay Name of the special function Rem A M R PV Par AQ P En Par Q ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 142: ...ue AQ see Chapter 4 4 26 Analog Ramp Control actual value AQ see Chapter 4 4 27 PI controller actual value AQ see Chapter 4 4 28 and Counter actual value Cnt see Chapter 4 4 13 Select the required function by means of the block number The timebase is adjustable Please note the following listing Symbol in IDEC SmartRelay Wiring Description Input Trg You start the on delay with a negative edge 1 to ...

Страница 143: ... If the referenced block B6 in the example returns a value that lies out of the valid range the value is rounded up or down to the next valid value Timebase max value min resolution Accuracy s seconds 99 99 10 ms 10 ms m minutes 99 59 1s 1 s h hours 99 59 1 min 1 min Timebase max value min resolution Accuracy ms 99990 Number of ms 10 ms s 5999 Number of s 1 s m 5999 Number of min 1 min ngineering ...

Страница 144: ... its timebase is shown 3 Press to move the cursor to the B of the shown block and then press to select the required block number 4 Press to move the cursor to the block s timebase and press to select the required timebase The view in parameter assignment mode example T 04 10h T 04 10 Ta 02 00h B12 B12 T B006m Ta 02 00h or current time T 04 10h B12 R T 04 10h B12 R B12 R B12 R T 04 10h T 04 10h Pre...

Страница 145: ... expiration of this time the output follows the input with on delay The time is reset when the status at input Trg returns to 0 be fore the time T has expired The output is reset to 0 when the signal at input Trg is 0 If retentivity is not set output Q and the expired time are re set after a power failure Trg T T Q Ta expires The bold section of the timing diagram is also shown in the On delay ico...

Страница 146: ...e Chapter 4 4 20 Analog multiplexer actual value AQ see Chapter 4 4 26 Analog Ramp Control actual value AQ see Chapter 4 4 27 PI controller actual value AQ see Chapter 4 4 28 and Symbol in IDEC SmartRelay Wiring Description Input Trg You start the off delay time with a negative edge 1 to 0 transition at input Trg Trig ger Input R A signal at input R resets the on delay time and the output Paramete...

Страница 147: ...DEC SmartRelay is retriggered at the 1 to 0 transition of Trg The output remains set Output Q is reset to 0 with off delay when Ta reaches the value config ured at T Ta T The time Ta is retriggered with a one shot at input Trg You can set input R Reset to reset the time Ta and the out put before Ta has expired If retentivity is not set output Q and the expired time are re set after a power failure...

Страница 148: ...negative edge 1 to 0 tran sition at input Trg Trigger triggers the off delay time TL Parameter TH is the time after which the output is set hi output signal transition 0 to 1 TL is the time after which the output is reset output signal transition 1 to 0 Retentivity No retentivity R The status is retentive Output Q Q is set when the configured time TH has expired and Trg is still set It is reset on...

Страница 149: ...0 be fore the time TH has expired A 1 to 0 transition at input Trg triggers the time TL If the status at input Trg is 0 at least for the duration of the signal TL the output is set to 0 on expiration of the time TL the output follows the input with off delay The time is reset when the signal at input Trg changes to 1 again before the time TL has expired If retentivity is not set output Q and the e...

Страница 150: ...ue AQ see Chapter 4 4 26 Analog Ramp Control actual value AQ see Chapter 4 4 27 PI controller actual value AQ see Chapter 4 4 28 and Counter actual value Cnt see Chapter 4 4 13 Select the required function by means of the block number The timebase is configurable For information on valid rang es and parameter defaults refer to Chapter 4 4 1 Symbol in IDEC Smart Relay Wiring Description Input Trg A...

Страница 151: ...t Trg does not influence the time Ta The output and the time Ta are reset with the next 1 signal at input R If retentivity is not set output Q and the expired time are re set after a power failure Trg T Q R T Ta expires The bold section of the timing diagram is also shown in the symbol of the retentive on delay ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670...

Страница 152: ...igger triggers the time for the Inter val time delay relay function Parameter The output is switched off af ter the time T has expired output signal transition 1 to 0 Retentivity No retentivity R The status is retentive Output Q A signal at input Trg sets Q If the input signal 1 output Q remains set for the time Ta Trg Q T Ta is expiring The bold section of the timing dia gram also appears in the ...

Страница 153: ... Output Q is reset to lo pulse output when Ta reaches the value preset at T Ta T The output is immediately reset if there is a 1 to 0 transition at input Trg before the specified time has expired If retentivity is not set output Q and the expired time are re set after a power failure ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 154: ...he times for the edge triggered interval time delay relay Input R A signal at input R resets the current time Ta and the out put Parameter The interpulse width TL and the pulse width TH are con figurable N determines the number of pulse pause cycles TL TH Range of values 1 9 Retentivity No retentivity R The status is retentive Output Q Q is set after TL has expired and reset after TH has ex pired ...

Страница 155: ... TL TH has expired Ta is reset and the pulse pause cycle is restarted If retentivity is not set output Q and the time are reset after a power failure Preset of the Par parameter View in programming mode example B25 1 R TL 02 00s TH 03 00s Protection mode and retentivity Interpulse width Pulse width Press B25 2 N 1 Number of pulse pause cycles example Trg N 2 Q TL TH TL TH TL TH TL TH Timing diagra...

Страница 156: ...EC SmartRelay Manual 146 View in parameter assignment mode example B25 TL 02 00s TH 03 00s Ta 01 15s Current pulse width TL or TH ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 157: ... reset the asynchronous pulse generator Input INV Input INV can be used to in vert the output signal of the active asynchronous pulse generator Parameter You can configure the pulse width TH and the interpulse width TL Retentivity No retentivity R The status is retentive Output Q Q is set and reset cyclically according to the pulse pause ratio TH and TL En Inv TH Q TL TH TL TH TL TH ngineering Inc...

Страница 158: ...Time High and TL Time Low parameters Input Inv can be used to invert the output signal provided the block is enabled with a signal at input EN If retentivity is not set output Q and the expired time are re set after a power failure ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 159: ... En Enable triggers the on delay time of the random generator A negative edge 1 to 0 tran sition at input En Enable triggers the off delay time of the random generator Parameter The on delay is set at ran dom to a value between 0s and TH The off delay is set at ran dom to a value between 0s and TL Output Q Output Q is set when the on delay has expired and if En is still set It is reset when the of...

Страница 160: ... expired A 1 to 0 transition at input EN triggers a random on delay time between 0s and TL The output is reset after the off delay time has expired pro vided input En remains lo at least for the duration of this time The time is reset if the signal at input En changes to 1 again before the off delay time has expired The time expired is reset after a power failure En Q TL TH T is busy The bold sect...

Страница 161: ...rg A signal at input Trg Trigger triggers the off delay time for the Stairwell Light Switch Parameter T represents the off delay time of the output output sig nal transition 1 to 0 T determines the triggering time for the pre warning T L determines the length of the pre warning signal Retentivity No retentivity R The status is retentive Output Q Q is reset after the time T has expired A warning si...

Страница 162: ...g period T L A further one shot at input Trg during Ta retriggers the time Ta If retentivity is not set output Q and the expired time are re set after a power failure Preset of the Par parameter Note the defaults specified in Chapter 4 3 2 Note All times must have the same timebase View in programming mode example B9 1 R T 60 00s Protection mode and retentivity Off delay time Press B9 2 T 05 00s T...

Страница 163: ...nctions 153 IDEC SmartRelay Manual View in parameter assignment mode example B9 1 T 60 00s Ta 06 00s Current value of T ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 164: ...arameter T represents the time after which f the output is reset output signal transition 1 to 0 TL represents the time during which the output must be set to enable the permanent lighting function T represents the preset time for the start of the off warning signal T L represents the length of the off warning period Retentivity No retentivity R The status is retentive Output Q A signal at Trg swi...

Страница 165: ... prior to the expiration of the off delay time to reset Q for the duration of the off warning signal T L A further signal at Trg always resets T and the output Q If retentivity is not set output Q and the expired time are re set after a power failure Preset of the Par parameter Note the defaults specified in Chapter 4 3 2 Note T T and T L must all have the same timebase View in programming mode ex...

Страница 166: ...T L 20 00s Start of the off warning period T T Off warning time View in parameter assignment mode example B5 1 T 60 00s TL 10 00s Ta 06 00s Current value of the time TL or T ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 167: ...Timing diagram three examples Cam No1 Daily 06 30 h to 08 00h Cam No2 Tuesday 03 10 h to 04 15h Cam No3 Saturday and Sunday 16 30 h to 23 10h Symbol in IDEC SmartRelay Wiring Description Cam parameters No1 No2 No3 At the Cam parameters you set the on and off times of the Seven day time switch for each Cam switch Here you also configure the days and the time of day Output Q Q is set when the config...

Страница 168: ...e cam3 takes priority over cam2 whereas cam2 takes priority over cam1 The switching state of the Seven day time switch is deter mined by the status of all three cams Parameter assignment screen form View of the parameter assignment screen form for example for Cam1 B1 1 D MTWTFSS On 06 30 Off 08 00 Block B1 Cam No1 See Showing hiding param eters Parameter protection mode on page 88 Weekdays daily O...

Страница 169: ... position of the on time 5 Set the on time Modify the value at the respective position using the keys and Move to the cursor to the various posi tions using the keys and At the first position you can only select the value means No on off times set 6 Press to move the cursor to the first position of the off time 7 Set the off time in same way as in step 5 8 Confirm your entries with OK The cursor i...

Страница 170: ...ires three cams Here are the parameter assignment screen forms of the cams No 1 2 and 3 based on the timing diagram shown ear lier Cam1 Cam No1 must set the output of the Seven day time switch daily from 05 30 h to 07 40 h B1 1 D MTWTFSS On 05 30 Off 07 40 Cam2 Cam No2 must set the output of the Seven day time switch every Tuesday from 03 10 h to 04 15 h B1 2 D T On 03 10 Off 04 15 ngineering Inc ...

Страница 171: ...ven day time switch switch every Saturday and Sunday from 16 30 h to 23 10 h B1 3 D SS On 16 30 Off 23 10 Result Q 1 1 2 3 1 1 1 1 1 3 Cam Monday Tuesday Wednesday Thursday Friday Saturday Sunday ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 172: ... time The off date iden tifies the day on which the output is reset again The first val ue identifies the month the second the day For MM you can select a placeholder so that the on and off time is set for a specific day each month Symbol in IDEC SmartRelay Wiring Description Cam parameter At the Cam parameter you configure the on off times for the cam of the Twelve month time switch Output Q Q is...

Страница 173: ...nth time switches with corresponding on times The outputs are then logically linked by means of an OR block B1 MM DD On 03 01 Off 04 04 On time March 1 Off time April 4 B2 MM DD On 07 07 Off 11 19 In addition On time July 7 Off time November 19 Result On Off B1 B2 March 1 at 00 00 h April 4 at 00 00 h November 19 at 00 00 h July 7 at 00 00 h ngineering Inc 230 Ryan Way South San Francisco CA 94080...

Страница 174: ...n time is the first and off time the second day each month B12 DD On 10 Off 20 Each month from the 10th through to the 20th B13 DD On 25 Off 05 In the next month from the 25th through the 5th ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 175: ...ring Description Input R A signal at input R resets the internal count value to zero Input Cnt The function counts the 0 to 1 transitions at input Cnt 1 to 0 transitions are not counted Use inputs I5 I6 for high speed counting only FL1D H12RCE FL1D B12RCE and FL1D H12SND max 2 kHz any other input or circuit component for counting low frequency signals typ 4 Hz Input Dir You set the direction of co...

Страница 176: ... are re set after a power failure Q is set or reset depending on the current value at Cnt and the set thresholds See the calculation rule below Parameter On On threshold Range of values 0 999999 Off Off threshold Range of values 0 999999 Retentivity for internal counter value Cnt No retentivity R The status is retentive Output Q Q is set or reset depending on the current value at Cnt and the set t...

Страница 177: ...ntrol actual value AQ see Chapter 4 4 27 PI controller actual value AQ see Chapter 4 4 28 and Counter actual value Cnt see Chapter 4 4 13 Select the required function by means of the block number For information on parameter defaults refer to Chapter 4 4 1 Note The system scans the counter limit value cyclically Thus if the pulse frequency at the fast inputs I5 I6 is faster than the cycle time the...

Страница 178: ...d block B6 in the example returns a value that lies out of the valid range the value is rounded to the next valid value The view in parameter assignment mode example B3 On 001234 Off 000000 Cnt 000120 B3 On 123456 Off B021 Cnt 000120 or Current count value ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 179: ...ed value MI at the counter for the duration of the time to go MN Input En En is the monitoring input IDEC SmartRelay scans the on time of this input Input Ral A positive edge at input Ral Re set all resets both the Operating hours counter OT and the out put and sets the configured val ue MI at the counter to for the duration of the time to go MN That is output Q 0 measured operating time OT 0 and ...

Страница 180: ...Range of values 0000 9999 h OT The accumulated total operating time you can specify an offset Range of values 00000 99999 h Q 0 When R is selected Q 1 if MN 0 Q 0 if R 1 or Ral 1 When R En is selected Q 1 if MN 0 Q 0 if R 1 or Ral 1 or En 0 Output Q The output is set when the time to go MN 0 see timing diagram The output is reset When Q 0 R En if R 1 or Ral 1 or En 0 When Q 0 R if R 1 or Ral 1 ngi...

Страница 181: ...r ating hours counter OT continues the count With a signal at the reset input Ral you reset output Q and set the preset value of MI at the counter for the duration of MN The Operating hours counter OT is reset to zero Depending on your configuration of parameter Q the output is either reset with a signal at input R or Ral Q 0 R or when a reset signal is set hi or the En signal is set lo Q 0 R En P...

Страница 182: ...OT continues the count as long as En 1 irrespective of the status at the reset input R The counter limit of OT is 99999 h The Operating hours counter stops when it reaches this val ue In programming mode you can set the initial value of OT The counter starts operation at any value other than zero MN is automatically calculated at the START based on the MI and OT values Example MI 100 OT 130 the re...

Страница 183: ...EC SmartRelay Manual View in parameter assignment mode B16 MI 0100h MN 0017h OT 00083h Time interval Time to go Total operating hours ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 184: ... I5 I6 for high speed counting only FL1D H12RCE FL1D B12RCE and FL1D H12SND max 2 kHz any other input or circuit com ponent for counting low fre quency signals typ 4 Hz Parameter On On threshold Range of values 0000 9999 Off Off threshold Range of values 0000 9999 G_T Time interval or gate time during which the input pulses are measured Range of values 00 05 s 99 99 s Output Q Q is set and reset a...

Страница 185: ...culation rule If the On threshold Off threshold then Q 1 if fa On Q 0 if fa Off If the On threshold Off threshold then Q 1 if On fa Off Preset of the Par parameter Note The system scans the counter limit value once per interval G_T View in programming mode example B15 1 On 0009 Off 0005 Parameter protection mode On threshold Off threshold Q Off 5 fa 9 fa 10 fa 8 fa 4 G_T Fre On 9 fa Input frequenc...

Страница 186: ...u preset a time G_T of 1 s the IDEC SmartRelay returns the current frequency in parameter fa in Hz View in parameter assignment mode example B15 On 0009 Off 0005 fa 0010 On threshold Off threshold Q 1 fa On Note fa always represents the total pulses measured per time unit G_T ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 187: ...to be analyzed at input Ax Use the analog inputs AI1 AI8 the Analog Memory Markers AM1 AM6 the block num ber of a function with analog output Parameter A Gain Range of values 10 00 B Offset Range of values 10 000 On On threshold Range of values 20 000 Off Off threshold Range of values 20 000 p Number of decimals Range of values 0 1 2 3 Output Q Q is set or reset by the threshold triggers ngineerin...

Страница 188: ...on The function fetches the analog signal at input Ax Ax is multiplied by the value of the A gain parameter and the value at parameter B offset is added to product i e Ax gain offset actual value of Ax Output Q is set or reset depending on the set thresholds See the calculation rule below Calculation rule If the On threshold Off threshold then Q 1 if the actual value Ax On Q 0 if the actual value ...

Страница 189: ...04000 Off 02000 Parameter protection mode On threshold Off threshold Press B3 2 A 01 00 B 00000 p 2 Gain Offset Decimals in the message text View in parameter assignment mode example B3 On 04000 Off 02000 Ax 05000 On threshold Off threshold Q 1 AX On View in the message text example 050 00 Ax when p 2 Q 1 AX On ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670...

Страница 190: ...yzed at input Ax Use the analog inputs AI1 AI8 the Analog Memory Markers AM1 AM6 the block num ber of a function with analog output Parameter A Gain Range of values 10 00 B Offset Range of values 10 000 On On Off threshold Range of values 20 000 Differential value for calculating the off parameter Range of values 20 000 p Number of decimals Range of values 0 1 2 3 Output Q Q is set or reset depend...

Страница 191: ...unctional description The function fetches the analog signal at input Ax Ax is multiplied by the value of the A gain parameter and the value at parameter B offset is added to product i e Ax gain offset actual value of Ax Output Q is set or reset depending on the set On threshold and difference value The function automatically calcu lates the Off parameter Off On whereby may be positive or negative...

Страница 192: ... B Preset of the Par parameter The gain and offset parameters are used to adapt the sen sors to the relevant application View in programming mode example B3 1 On 04000 02000 Parameter protection mode On Off threshold Differential value for the On Off threshold Press B3 2 A 01 00 B 00000 p 2 Gain Offset Decimals in the message text View in parameter assignment mode example B3 On 04000 02000 Ax 0500...

Страница 193: ...IDEC SmartRelay functions 183 IDEC SmartRelay Manual Press B3 Off 02000 Off threshold ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 194: ...fference you want to analyze at the inputs Ax and Ay Use the analog inputs AI1 AI8 the Analog Memory Markers AM1 AM6 the block num ber of a function with analog output Parameter A Gain Range of values 10 00 B Offset Range of values 10 000 On On threshold Range of values 20 000 Off Off threshold Range of values 20 000 p Number of decimals Range of values 0 1 2 3 Output Q Q is set or reset depending...

Страница 195: ... the analog values from the inputs Ax and Ay Ax and Ay are each multiplied by the value of the A gain pa rameter and the value at parameter B offset is then added to the relevant product i e Ax gain offset actual value Ax or Ay gain offset actual value Ay The function forms the difference between the actual values Ax Ay Output Q is set or reset depending on difference of the ac tual values Ax Ay a...

Страница 196: ...eter protection mode On threshold Off threshold Press B3 2 A 00 00 B 00000 p 0 Gain Offset Decimals in the message text Example In a heating control system the supply Tv and return line temperatures Tr are to be compared for example with a sen sor at AI2 A control signal is to be triggered for example heater On when the difference between the supply and return line tem peratures is greater than 15...

Страница 197: ...2 A 00 10 B 00030 p 0 Gain Offset Decimals in the message text if used View in parameter assignment mode example B3 1 On 00015 Off 00005 On threshold Off threshold Application Internal mapping 30 to 70 C 0 to 10 V DC 0 to 1000 0 C 300 Offset 30 Range of values 30 to 70 C 100 1000 Gain 100 1000 0 1 On threshold 15 C Threshold 15 Off threshold 5 C Threshold 5 ngineering Inc 230 Ryan Way South San Fr...

Страница 198: ...by means of the On delay and Off delay special func tions With on delay output Q is only set if the pulse width of the triggering signal at input Trg analog comparator out put is longer than the on delay time Using this method you will obtain a virtual hysteresis and re duce the input response to short signals Function block diagram Q1 AI A AI AI1 AI2 B1 B2 B3 Analog comparator On delay Off delay ...

Страница 199: ...put En saves the analog val ue at input Ax Aen to memory and starts monitoring of the ana log range Aen Input Ax You apply the analog signal to be monitored at input Ax Use the analog inputs AI1 AI8 the Analog Memory Markers AM1 AM6 the block number of a function with analog output Parameter A Gain Range of values 10 00 B Offset Range of values 10 000 Difference value for the Aen on off threshold ...

Страница 200: ...red to as Aen Both the analog actual values Ax and Aen are multiplied by the value at parameter A gain and parameter B offset is then added to the product i e Ax gain offset Actual value Aen when input En chang es from 0 to 1 or Ax gain offset Actual value Ax Output Q is set when the signal at input En 1 and if the ac tual value at input Ax is out of range of Aen Output Q is reset when the actual ...

Страница 201: ...ew in programming mode B3 1 00000 Parameter protection mode Differential value for the on off threshold Press B3 2 A 00 00 B 00000 p 0 Gain Offset Decimals in the message text View in parameter assignment mode example B3 00010 Aen 00020 Ax 00005 Q 1 Ax is out of the range of Aen ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 202: ...Symbol in IDEC SmartRelay Wiring Description Input Ax You apply the analog signal to be amplified at input Ax Use the analog inputs AI1 AI8 the Analog Memory Markers AM1 AM6 the block number of a function with analog output Parameter A Gain Range of values 10 00 B Offset Range of values 10 000 p Number of decimals Range of values 0 1 2 3 Output AQ This special function has an an alog output This o...

Страница 203: ...ion to a value range of 0 to 1000 Scaling an analog input value You can influence the analog input value of a potentiometer by interconnecting an analog input with an analog amplifier and an analog memory marker Scale the analog value at the analog amplifier for further use Connect for example the time base for parameter T of a time function e g On Off delay Chapter 4 4 3 or the on and or off limi...

Страница 204: ...elay functions IDEC SmartRelay Manual 194 View in parameter assignment mode example B3 A 02 50 B 00300 AQ 00250 ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 205: ...current status of the output signal is retained after a power failure Symbol in IDEC SmartRelay Wiring Description Input S You set output Q with a sig nal at input S Input R You reset output Q with a signal at input R If S and R 1 the output is reset Parameter Retentivity No retentivity R The status is retentive Output Q Q is set with a signal at input S and reset with a signal at input R S R Q Co...

Страница 206: ...tput Q with a sig nal at input S Input R You reset output Q with a signal at input R Parameter Selection RS R input priority or SR S input priority Retentivity No retentivity R The status is retentive Output Q Q is set with a signal at Trg and reset with the next signal at Trg if S and R 0 Trg Q R S The bold printed section of the timing diagram is also shown in the symbol for the current impulse ...

Страница 207: ...e the output is set hi You reset the current impulse relay with a signal at input R i e the output is set lo Status diagram RS or SR Triggering signal is effective because S and R 0 Par Qn 1 S R Trg Qn 0 0 0 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 1 0 1 0 0 1 0 0 1 0 1 0 0 1 1 RS 0 1 1 0 0 RS 0 1 1 0 1 0 SR 0 1 1 0 1 SR 0 1 1 0 1 1 1 0 0 0 1 1 0 0 0 1 0 1 0 1 0 0 1 0 1 0 1 0 1 1 0 0 1 1 1 0 0 1 1 RS 1 1 1 0...

Страница 208: ...rrent impulse relay and output Q are reset if you have not enabled retentivity View in programming mode B29 R Par RS B29 R Par SR Press or This special function is not available in parameter assign ment mode Note If Trg 0 and Par RS the special function Current impulse relay corresponds with the special function Latching relay see Chapter 4 4 21 ngineering Inc 230 Ryan Way South San Francisco CA 9...

Страница 209: ...arameter Text Input of the message text Par Parameter or actual value of another al ready programmed function see Visible parameters or process variables Time Display of the continu ously updated time of day Date Display of the continu ously updated date EnTime Display of the time of the 0 to 1 transi tion of the signal at input En EnDate Display of the date of the 0 to 1 transi tion of the signal...

Страница 210: ...ges from 1 to 0 the message text is output until it is acknowledged with OK When En 1 you can not acknowledge the message text When multiple message text functions are triggered with En 1 the message text that has the highest priority is shown 0 lowest 30 highest This also means that a newly ac tivated message text is shown only if its priority is higher than that of previously activated message t...

Страница 211: ...t with priority 10 Date and current time of day only for versions with real time clock Input P configuration To configure the priority and the acknowledgment program ming mode B33 Priority 00 Quit Off means The parameters and actual values in an active message text can be edited Priority Status of the acknowledgment 1 Increase the priority to 1 Cursor on 0 2 Change to Quit Press 3 Enable Quit Pres...

Страница 212: ...ntive on delay T Ta Interval time delay relay Pulse output T Ta Edge triggered interval time de lay relay Ta TH TL Asynchronous pulse generator Ta TH TL Random generator TH TL Stairwell Light Switch Ta T T T L Dual function switch Ta T TL T T L Seven day time switch 3 on off day Twelve month time switch On Off Counter Up down counter Cnt On Off Operating hours counter MI Q OT Frequency trigger fa ...

Страница 213: ...anges with OK You can now edit further pa rameters in the message text if any exist Press ESC to exit editing mode Key input simulation in the active message text You can enable the four cursor keys C C C and C in an active message text by pressing ESC plus the relevant cursor key Analog value monitoring A B Ax Aen Analog amplifier A B Ax Analog multiplexer V1 V2 V3 V4 AQ Analog Ramp Control L1 L2...

Страница 214: ...ect ed Press or to select the letter to be displayed in the text To move the cursor from one position to the other press or The list of available characters is here the same as for the circuit program name The character set is found in Chapter 3 6 4 Press OK to confirm your changes and press ESC to exit the editing mode To output a parameter e g a process variable or function value as message text...

Страница 215: ...ks to be displayed and the corresponding parameters Press or to select the block or parameter you want to view Select the parameter by pressing OK Press ESC to exit the parameter assignment mode and to apply your changes ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 216: ... confirmed in parameter assignment mode Parameter Programming mode Selecting the function for pushbutton action for the du ration of one cycle or for switching action Start On or off state initial ized at the first start of the program if retentiv ity is disabled Retentivity No retentivity R The status is retentive Parameterassignmentmode RUN mode Switch Switches the mo mentary pushbutton or switc...

Страница 217: ...sition Off was selected at the Switch pa rameter and confirmed with OK in parameter assignment mode If retentivity is not set output Q is initialized after a power fail ure according to your configuration at the Start parameter Preset of the Par parameter View in programming mode example 1 Select the SoftkeyE function 2 Select input En and confirm with OK The cursor is now positioned below Par 3 C...

Страница 218: ...elay shows the following display B33 Switch Off The momentary pushbutton switch is here switched off Let us assume you want to set Switch On 1 Change to the editing mode Confirm with OK the cursor is now positioned on Off 2 To change from Off to On Press or 3 Confirm your entries with Press OK B33 On Off Start On The status is not retentive Switch function Q is set in the first cycle after the pro...

Страница 219: ...tRelay functions 209 IDEC SmartRelay Manual B33 Switch On The momentary pushbutton switch is here switched on ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 220: ...art of the function Input Trg A positive edge 0 to 1 transi tion at input Trg Trigger starts the special function 1 to 0 transitions are irrelevant Input Dir The signal at input Dir deter mines the shifting direction for the shift register bits S1 S8 an Dir 0 Shift up S1 S8 Dir 1 Shift down S8 S1 Shift register bit that deter mines the value at output Q Possible settings S1 S8 Retentivity No reten...

Страница 221: ... is shifted to S7 the previous value at S7 is shifted to S6 etc Output Q returns the value of the configured shift register bit If retentivity is disabled the shift function restarts at S1 or S8 after a power failure When enabled retentivity always ap plies to all shift register bits Note The special function shift register can be used only once in the cir cuit program Timing diagram Trg In Q Dir ...

Страница 222: ...eter View in programming mode B3 R Q S8 Retentivity enabled Preset Press B3 R Q S7 etc You can select S8 S1 This special function is not available in parameter assign ment mode ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 223: ...change in status from 0 to 1 at input En Enable switches a parameterized analog value to the output AQ depending on the value of S1 and S2 Inputs S1 and S2 S1 and S2 selectors for selecting the analog value to be issued S1 0 and S2 0 Value 1 is issued S1 0 and S2 1 Value 2 is issued S1 1 and S2 0 Value 3 is issued S1 1 and S2 1 Value 4 is issued ngineering Inc 230 Ryan Way South San Francisco CA 9...

Страница 224: ...ontroller actual value AQ see Chapter 4 4 28 and Counter actual value Cnt see Chapter 4 4 13 Select the required function by means of the block number For information on parameter defaults refer to Chapter 4 4 1 Parameter V1 V4 Analog values that will be issued Range of values 32768 32767 p Number of decimals Range of values 0 1 2 3 Output AQ This special function has an analog output This output ...

Страница 225: ...ssues the analog value 0 at output AQ Analog output If you interconnect this special function with a real analog output note that the analog output can only process values between 0 and 1000 To do this you may need to connect an additional amplifier between the analog output of the special function and the real analog output Using this amplifier you standardize the output range of the special func...

Страница 226: ...r View in programming mode example B3 1 V1 04000 V2 02000 B3 2 V3 B020 V4 B021 p 0 Press View in parameter assignment mode B3 1 V1 04000 V2 02000 B3 2 V3 B020 V4 B021 AQ 4000 Press ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 227: ...to the selected level A change in the status from 1 to 0 immediately sets the output AQ to 0 Input Sel SeI 0 Level1 is selected SeI 1 Level2 is selected A change instatus of Sel caus es the output AQ to start changing to the selected level at the specified rate Input St A change in the status from 0 to 1 at input St Decelerated Stop causes AQ to decrease at a constant rate until the start stop lev...

Страница 228: ... that is added to Offset B to create the start stop lev el If the Start Stop offset is 0 then the start stop level is Offset B Range of values 10 000 to 20 000 Rate Acceleration with which level 1 level 2 or Offset is reached Steps seconds are issued Range of values 1 to 10 000 A Gain Range of values 0 to 10 00 B Offset Range of values 10 000 p Number of decimals Range of values 0 1 2 3 ngineering...

Страница 229: ...PI controller actual value AQ see Chapter 4 4 28 and Counter actual value Cnt see Chapter 4 4 13 Select the required function by means of the block number For information on parameter defaults refer to Chapter 4 4 1 Symbol in IDEC SmartRelay Wiring Description Output AQ The output AQ is scaled using the formula Current Level Offset B Gain A Range ofvalues 0 to 32767 Note When AQ is displayed in pa...

Страница 230: ...y Offset B is issued at output AQ The scaled value is 0 If the input St isset the function can only be restarted once the inputs St and En have been reset If input Sel has been changed depending on the connection of Sel the function runs from the current target level to the new target level at the rate that is specified If the input En is reset the function immediately sets the out put AQ to 0 The...

Страница 231: ...xL 7000 StSp 00222 Rate 00500 B3 3 A 02 50 B 00300 p 0 Gain Offset Decimals in the message text Press Press View in parameter assignment mode B3 1 L1 04000 L2 B020 AQ 00250 B3 2 StSp 00222 Rate 00500 B3 3 A 02 50 B 00300 Gain Offset Press Press ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 232: ...ol in IDEC SmartRelay Wiring Description Input A M Set the mode of the controller 1 automatic mode 0 manual mode Input R Use the input R to reset the output AQ As long as this input is set the input A M is disabled Output AQ is set to 0 Input PV Analog value process value influences the output A M R PV Par AQ ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4...

Страница 233: ...99 59 m Dir Action direction of the controller Range of values or Mq Value from AQ with manual mode Range of values 0 to 1000 Min Minimum value for PV Range of values 10 000 to 20 000 Max Maximum value for PV Range of values 10 000 to 20 000 A Gain Range of values 10 00 B Offset Range of values 10 000 p Number of decimals Range of values 0 1 2 3 ngineering Inc 230 Ryan Way South San Francisco CA 9...

Страница 234: ...ounter actual value Cnt see Chapter 4 4 13 Select the required function by means of the block number For information on parameter defaults refer to Chapter 4 4 1 Parameters KC TI Please note If parameter KC has value 0 the P function proportional control will not be executed If parameter TI has value 99 59 m the I function integral action control will not be executed Symbol in IDEC SmartRelay Wiri...

Страница 235: ...s Min Max PV SP Q 1 A disturbance causes the PV to drop as Dir is positioned upwards AQ increases until PV corresponds again to SP 2 A disturbance causes the PV to drop as Dir is positioned downwards AQ decreases until PV corresponds again to SP It is not possible to change the direction Dir at runtime of the function The change is shown here for illustrative purposes only 3 As AQ is set to 0 by m...

Страница 236: ... then the special function reduces the value of AQ If the updated value PV SP then the special function increases the value of AQ Dir downwards timing diagram number 2 If the updated value PV SP then the special function increases the value of AQ If the updated value PV SP then the special function reduces the value of AQ With a disturbance AQ continues to increase decrease until the updated value...

Страница 237: ...lication related parameter sets for KC TI and Dir refer to the online help for WindLGC Preset of the Par parameter View in programming mode example B3 1 SP B020 B3 2 KC 10 00 TI 01 00 Dir B3 4 A 02 50 B 00300 p 0 B3 2 KC TI B3 3 Mq B021 Min 05000 Max 05000 Press Press Press ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 238: ...ew in parameter assignment mode B3 1 SP B020 PV 0 AQ 0250 B3 2 KC 10 00 TI 01 00 Dir B3 4 A 02 50 B 00300 B3 3 Mq B021 Min 05000 Max 05000 Press Press Press ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 239: ...mode In programming mode the author of the circuit program also sets the parameters We have added the parameter assignment mode to allow the editing of parameters without having to modify the circuit program This feature is available for the user to edit param eters without having to change to programming mode for example The advantage The circuit program remains pro tected but can be adapted by t...

Страница 240: ...27 Mo 09 00 ESC Press Note The following applies to earlier device versions up to 0BA2 You open parameter assignment mode by pressing ESC OK IDEC SmartRelay changes to parameter assignment mode and opens the parameter assignment menu Stop Set Param Set Prg Name ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 241: ...To confirm Yes Press OK IDEC SmartRelay shows the main menu of the programming mode Program Card Setup Start Set Param For information on the various parameters refer to the Chapters 5 1 1 to 5 1 3 Set For information on the various settings refer to Chapter 5 2 Prg Name This menu command only allows you to read the name of your circuit program It is not possible to modify this name in parameter a...

Страница 242: ...rameters are for example The delay times of a time relay The switching times cams of time switch Counter thresholds The monitoring time for hour counters The trigger thresholds Each one of the parameters is identified by its block number Bx and the shortname of the parameter Examples T is a configurable time MI is a configurable time interval Note WindLGC also allows you to assign names to blocks ...

Страница 243: ... assignment menu 3 Now select the desired parameter Press or 4 Select the parameter you want to edit and press OK Stop Set Param Set Prg Name B9 1 Press ESC No Param T 60 00s Ta 06 00s Block number Display number for functions with several displays The value set at parameter T Time The current time in the IDEC SmartRelay No parameters for editing Press ESC to return to the parameter assignment men...

Страница 244: ... you can also change the timebase s seconds m minutes h hours This does not apply if the time parameter represents the re sult of another function for an example see Chapter 4 4 1 In this case you can neither change the value nor the timebase The current time is reset to zero when you change the timebase Current value of a time T View of a time T in parameter assignment mode B9 Ta 06 00s T 80 00s ...

Страница 245: ...ff B021 Cnt 000120 or Current count value You can change the On Off threshold This does not apply if the on or off threshold represents the result of another func tion in the example this is B21 see Chapter 4 4 13 Current value of an hour counter View of an hour counter parameter in parameter assignment mode B16 MI 0100h MN 0017h OT 00083h Time interval Time to go Total operating hours You can edi...

Страница 246: ...gger View of the parameter of a frequency trigger in parameter as signment mode B15 On 0009 Off 0005 fa 0010 On threshold Off threshold Process variable You can change the On Off threshold ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 247: ...e Chapter 3 6 14 Contrast settings You can set the default value for the display contrast in parameter assignment mode by means of the set menu Contrast menu item in programming mode by means of the setup menu Contrast menu item See Chapter 5 2 2 Start screen settings You can select the default setting for the start screen in parameter assignment mode by means of the set menu StartScreen menu item...

Страница 248: ...artRelay is equipped with a real time clock You set the real time clock of IDEC SmartRelay by means of the Set Clock command IDEC SmartRelay shows the following display Set Clock Mo 15 30 YYYY MM DD 2005 01 27 The cursor is positioned on the weekday 8 Select the day of the week Press or 9 Move the cursor to the next position Press or 10 To change the value Press or 11 To set the correct TOD repeat...

Страница 249: ...menu item To set the display contrast in parameter assignment mode 1 Select parameter assignment mode see Chapter 5 1 2 On the parameter assignment menu select Set Press or 3 Confirm Set Press OK 4 Move the cursor to Contrast Press or 5 Confirm Contrast Press OK IDEC SmartRelay shows the following display Contrast 6 To change the display contrast Press or 7 To confirm your entry Press OK To set th...

Страница 250: ... Set Press or 3 Confirm Set Press OK 4 Move the cursor to StartScreen Press or 5 Confirm StartScreen Press OK IDEC SmartRelay shows the following display Clock Input DI StartScreen Clock The current setting of the start screen is shown in the bottom row The default setting is Clock You can choose between the display of the current time of day and date or the values of the digital inputs 6 Select t...

Страница 251: ...chiving circuit programs Reproducing circuit programs Write and test your circuit program at the office and then transfer it to a IDEC SmartRelay in the switching cabinet IDEC SmartRelay is supplied with a hood The memory car tridge card is supplied separately Note You do not need a module to backup the circuit program in your IDEC SmartRelay The IDEC SmartRelay circuit program is automatically st...

Страница 252: ...versions FL1A or FL1B devices can not be used in IDEC SmartRelay devices of the FL1C or FL1D generation When the IDEC SmartRelay system detects such an old memory cartridge card the message Unknown Card Press ESC is output to the display Vice versa an FL1C or FL1D memory cartridge card can not be used in IDEC SmartRelay devices of the FL1A or FL1B family Upward compatibility of circuit programs Ci...

Страница 253: ... execute this circuit program in IDEC SmartRelay the pro tected memory cartridge card must remain inserted during RUN i e the circuit program stored on the memory cartridge card can not be copied to other IDEC SmartRelay devices Over and above that a protected circuit program is write protected A circuit program with password protection is no longer pro tected after the correct password has been e...

Страница 254: ...ESC Stop 2 The main menu opens To select the Card command Press or 3 To apply Card Press OK 4 Move the cursor to CopyProtect Press or 5 To apply CopyProtect Press OK IDEC SmartRelay shows the following display No Yes CopyProtect No The current protection setting is shown in the bottom line This function is disabled by default No disabled Password Protection Editing Copying Deleting Yes Yes Yes Yes...

Страница 255: ...ory cartridge card the circuit program itself must be copied separately from the IDEC SmartRelay to the memory cartridge card can also be done initially You can always change the No status security function disabled to Yes security function enabled A status change from Yes security function enabled to No se curity function disabled is only possible if the memory cartridge card does not contain a c...

Страница 256: ...rtridge card IDEC SmartRelay outputs the message No Program A removal of the memory cartridge card during RUN will lead to imper missible operating states Always heed the following warning Warning Do not touch the open slot of the memory cartridge card neither with your fingers nor with a metallic or conductive object The memory cartridge card socket may be under voltage if the polarity is acciden...

Страница 257: ...ory cartridge removal tool MT 101 and pull the memo ry cartridge straight out Inserting a memory cartridge card The entry of the memory cartridge card slot is chamfered on its bottom right The edge of the memory cartridge card is chamfered accordingly This encoding prevents you from inserting the memory cartridge card the wrong way round Insert the memory cartridge card into the slot and push it i...

Страница 258: ...o select the Card command Press or 4 Press OK The transfer menu opens 5 Move the cursor to IDEC SmartRelay Card if re quired Press or 6 Press OK IDEC SmartRelay now copies the circuit program to the memory cartridge card When IDEC SmartRelay has finished copying it automati cally returns you to the main menu Program Card Setup Start Program Card Setup Start IDEC SmartRelay main menu Card Card Copy...

Страница 259: ...forget to replace the cap If power fails while IDEC SmartRelay is copying the circuit program repeat the process after Power On Note The password X of a protected circuit program in IDEC SmartRelay also applies to the copied program version on your memory car tridge card ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 260: ...X the copied program in the IDEC SmartRelay is also protected with the same password Automatic copying during the startup of IDEC SmartRelay Proceed as follows 1 Switch off the power supply to IDEC SmartRelay POWER OFF 2 Remove the slot cover 3 Insert the memory cartridge card into the relevant slot 4 Switch on the power supply to the IDEC SmartRelay IDEC SmartRelay copies the program from the mem...

Страница 261: ...from the memory cartridge card to IDEC SmartRelay 1 Insert the memory cartridge card 2 Switch IDEC SmartRelay to programming mode ESC Stop 3 Move the cursor to Card Press or 4 Press OK The transfer menu opens 5 Move the cursor to Card IDEC SmartRelay Press or 6 Press OK IDEC SmartRelay copies the circuit program from the memory cartridge card to IDEC SmartRelay When IDEC SmartRelay has finished co...

Страница 262: ...ircuit programs Easy configuration of blocks Transferring the circuit program from IDEC SmartRelay to the PC and from the PC to IDEC SmartRelay Reading the values of the hour counter Setting the TOD Summertime wintertime conversion Online test Display of status changes and process vari ables of IDEC SmartRelay in RUN mode Status of a digital I O markers shift register bits and cursor keys The valu...

Страница 263: ...to the file system on your PC to make it directly available for any modifi cations 5 It takes only a few key actions to download the circuit program to IDEC SmartRelay WindLGC WindLGC runs under Windows 95 98 Windows NT 4 0 Windows Me Windows 2000 and Windows XP WindLGC is capable of client server operation and offers you a high degree of freedom and comfort for creating your circuit program WindL...

Страница 264: ... processed first and then the outputs Thus the output results are not reflected on the inputs within the same scan time but rather they are reflected at the following scan ex Interlock is not activated in the sample program 1 below in which input terminals I1 and I2 are simultaneously turned on The interlock is activated in the sample program 2 below in which input terminals I1 and I2 are simultan...

Страница 265: ... the instructions on the screen when you install the driver for the converter Make sure you specify the correct Windows OS version when you select the driver Switching IDEC SmartRelay to PC IDEC SmartRelay mode 1 Switch the IDEC SmartRelay with without display to STOP from your PC refer to the WindLGC Online Help or select the ESC Stop command on a device with dis play and confirm the entry with Y...

Страница 266: ...d with WindLGC is password protected both the circuit program and the password are downloaded to IDEC SmartRelay The password prompt is enabled at the end of the data transfer The upload of a password protected program created in IDEC SmartRelay is only possible after the correct password is entered in WindLGC ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 ...

Страница 267: ...it diagram and com pared it with the IDEC SmartRelay solutions You can find solutions for the following tasks Page Stairway or corridor lighting system page 259 Automatic door page 263 Ventilation system page 270 Factory gate page 275 Central controlling and monitoring of several factory gates page 279 Luminous rows page 283 Service water pump page 287 ngineering Inc 230 Ryan Way South San Francis...

Страница 268: ...sponsibility We refer to the relevant national standards and system related installation reg ulations Although you have four inputs available for logic operations basic functions see Chapter 4 2 the following figures will only show a maximum of three inputs for reasons of clarity You program this fourth input and assign parameters just like the other three inputs Errors can not be ruled out and th...

Страница 269: ...off in order to save energy 8 1 2 Previous solution The two conventional options for switching the lights With a pulse relay With an automatic stairway lighting switch The wiring of both these lighting systems is identical Lights Distribution box Push buttons Distribution with Current impulse relay or automatic stairway lighting switch Components used Momentary switches Automatic stairway lighting...

Страница 270: ...eaning the stairway The switch for permanent lighting is usually located on the auto matic stairway lighting switch and may be difficult or impos sible to access 8 1 3 Lighting system with IDEC SmartRelay A IDEC SmartRelay system allows you to replace the auto matic stairway lighting switch or the Current impulse relay You can also implement both functions timed off delay and Current impulse relay...

Страница 271: ...ary functions are entered directly in IDEC SmartRelay Current impulse relay with IDEC SmartRelay Output Q1 is toggled with a pulse signal at input I1 Automatic stairway lighting switch with IDEC SmartRelay Output Q1 is set for the duration of 6 minutes with a pulse signal at input I1 L1 N I1 I3 I6 I7 I8 Q1 Q2 Q3 Q4 L N PE I4 I5 I1 I2 I3 I1 I2 I3 Lamps Switches I1 Q1 x Switch Lamps I1 Q1 T 06 00m M...

Страница 272: ... flashing function that indicates that the light is about to be switched off automatically You can integrate various central functions Central off Central on panic button Control of all lamps or individual circuits by means of a daylight control switch Controlling by means of an integrated timer e g permanent lighting only until 24 00 h disabled at specific times Automatically switching off the pe...

Страница 273: ...ared When the doorway is cleared the door must close auto matically with a short delay B1 B2 Q1 S1 S2 Outside inside Motion detector Limit switch closed Limit switch open Motion detector Master switch Motion detector Master switch The door is usually driven by a motor that is equipped with a slip coupling This prevents people from being squeezed in and injured The control system is connected to th...

Страница 274: ...ng motion is initiated by setting K3 After the detection range of the two motion sensors has been cleared at least for a minimum time K4 enables the closing motion 8 2 3 Door control system with IDEC SmartRelay IDEC SmartRelay can simplify this circuit considerably You only need to connect the motion sensors limit switches and the contactor relays to the IDEC SmartRelay ngineering Inc 230 Ryan Way...

Страница 275: ...contact limit switch close S2 normally closed contact limit switch open B1 normally open contact infrared motion sensor outside B2 normally open contact infrared motion sensor inside L1 N I4 I5 I6 I7 I8 Q1 Q2 Q3 Q4 K1 K2 B1 B2 S2 S1 L1 N I1 I2 I3 1 2 1 2 1 2 1 2 Open Close ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 276: ...Relay functions You can use the off delay function to replace the latching relay and the on delay The block dia gram below illustrates this simplification 1 1 1 I4 I3 I1 I2 x Q2 Q1 x 10 s Q1 Q2 Open Close Close Motion detector Limit switch Door open Limit switch Door closed 1 1 1 I4 I3 Q2 Q1 RS I1 I2 1 I4 T 4s x x Q1 Q2 Open Close ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 Gener...

Страница 277: ...EC Smar tRelay to warn of the closing of the door You can enable opening of the door time and direc tion dependent i e opening only during business hours and opening only from the inside after closing time 8 2 5 Extended solution with FL1D H12RCC Wiring the IDEC SmartRelay extended solution L1 N I4 I5 I6 I7 I8 K1 K2 B1 B2 S2 S1 L1 N S3 H1 Q1 Q2 Q3 Q4 I1 I2 I3 1 2 1 2 1 2 1 2 Open Close Buzzer ngin...

Страница 278: ...00 Cam1 Day Mo Fr On 09 00 Off 19 00 Cam2 Day Sa On 08 00 Off 14 00 Motion detector B1 Motion detector B2 Actuate motor for opening Open Close Close output Limit switch Door open Control switch Door open Actuate motor for closing Limit switch Door closed Open output Motion detector B1 Motion detector B2 Control switch Close door ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General...

Страница 279: ... nently open or The motion detectors indicate that somebody is ap proaching the door and The door has not yet fully opened limit switch at I4 Actuating the motor for closing Output Q2 is set to close the door when The control switch at I6 is actuated the door is perma nently closed or The motion detectors indicate that there is nobody near the door and The door has not yet fully closed limit switc...

Страница 280: ...n Flow sensor Flow sensor Exhaust fan The room is equipped with an exhaust fan and a fresh air fan Both fans are monitored by means of a flow sensor An excess atmospheric pressure may never develop in the room The fresh air fan must only be switched on if safe func tioning of the exhaust fan is signaled by the flow sensor A warning lamp indicates failure of a fan ngineering Inc 230 Ryan Way South ...

Страница 281: ... message is output This message can be acknowledged by pressing the OFF button In addition to the flow sensors the fan monitoring system also requires an evaluating circuit with several switching de vices This evaluating circuit can be replaced by a single IDEC SmartRelay unit Wiring of an air conditioning system with FL1D H12RCC L1 N I1 I3 I6 I7 I8 Q1 Q2 Q3 Q4 K1 K2 S1 L1 N S2 S3 v v H1 H2 S0 I4 ...

Страница 282: ...l lamp H2 signal lamp Block diagram of the IDEC SmartRelay solution The block diagram of the air conditioning system with IDEC SmartRelay x I1 Q3 I2 Q1 Q2 Q1 I3 x I2 x T 10 s x T 10 s x x x I3 I4 Q1 Q2 Q3 Exhaust fan On Error Off Exhaust fan Exhaust air flow sensor Fresh air flow sensor Fresh air fan Exhaust fan Exhaust air flow sensor Fresh air fan Error Off ngineering Inc 230 Ryan Way South San ...

Страница 283: ...It is possible to switch off of the fans by means of a se quential circuit These functions can be implemented without additional switchgear Block diagram of the extended IDEC SmartRelay solution The fans at Q1 and Q2 are switched on and off by means of the following circuit x T 10 s T 30 s Q1 Q2 I2 Q3 x x I3 I2 T 10 s T 10 s x x x I3 I4 Q3 I1 Q2 On Fault Off Exhaust air flow sensor Q1 exhaust fan ...

Страница 284: ... contacts of output Q4 are always closed when the system is in operation Relay Q4 does not drop off unless there is a power failure or a fault in the system This contact can be used for remote monitoring for example ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 285: ...se The porter can monitor the operation of the gate at the same time The gate is normally fully opened or fully closed The gate motion can be interrupted at any time An indicator lamp is switched on five seconds before the gate starts moving and when the gate is in motion A safety pressure bar prevents harm to persons and ob jects from getting trapped or damaged when the gate is closing Safety pre...

Страница 286: ... K2 L1 N K1 H1 K4 S5 p K6 K6 K1 S2 S2 K3 K2 K4 K5 S5 p S1 K3 K1 S4 S3 Open Close Indicator lamp Open Close Auxiliary circuit Wiring of a gate control system with FL1D H12RCC L1 N I4 I5 I6 I7 I8 Q1 Q2 Q3 Q4 K1 K3 S4 S3 L1 N S1 S2 S0 S5 p S5 p H1 I1 I2 I3 1 2 1 2 1 2 1 2 Open Close Indicator lamp ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 287: ...SE pushbuttons initiate the gate motion provided it is not already moving in the other direction The gate is stopped by means of the STOP pushbutton or the rel evant limit switch A safety bar furthermore interrupts the closing motion of the gate T 5 s T 5 s x x x x Q1 Q3 Q2 I3 I4 I3 I6 I5 I1 I2 Q2 Q1 TH TL 2 s Inv lo I2 I1 Start push button CLOSED Start push button OPEN STOP push button Gate is op...

Страница 288: ...n the safety bar is actuated x x I6 x Q2 I3 I4 x I1 Q2 T 5 s Q1 T 5 s x Q2 I3 I6 I5 I2 Q1 Q3 TH TL 2 s Inv lo Safety bar STOP pushbutton Gate is open OPEN pushbutton CLOSE pushbutton STOP pushbutton Safety bar Gate is closed Open Signal lamp Close ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 289: ...atehouse It must also be possible for a member of staff to open and close the gate locally For each gate we are going to use one FL1D H12RCC and one communication module The modules and the master are interconnected by means of a bus system This chapter describes a gate control system The structures of the other gate control systems are identical 1 2 1 2 1 2 Door I Door II Door III 1 Safety bar 2 ...

Страница 290: ... or GATE CLOSED status is indicated An indicator lamp is switched on five seconds before the gate starts moving and when the gate is in motion A safety pressure bar prevents harm to persons and ob jects from getting trapped or damaged when the gate closes Wiring of the gate control system with FL1D H12RCC and CM AS Interface N L1 N I3 I4 I5 I6 I7 I8 K1 K2 L1 S0 S1 S2 S3 S4 S5 S6 p S6 p I2 I1 Q1 Q2...

Страница 291: ...S3 normally open contact CLOSE pushbutton S4 normally closed contact position sensor GATE IS OPEN S5 normally closed contact position sensor GATE IS CLOSED S6 normally closed contact Safety bar Master control system Q5 position sensor GATE IS OPEN Q6 position sensor GATE IS CLOSED I9 external pushbutton OPEN GATE I10 external pushbutton CLOSE GATE ngineering Inc 230 Ryan Way South San Francisco CA...

Страница 292: ...pective limit switch Closing of the gate is also interrupted by the safety bar Gate is open Open gate Open gate Gate is open Open gate by hand Gate is open Close gate by hand Gate is closed Safety bar Gate is closed Close Closed Safety bar Gate is closed Safety bar Gate is open Gate is closed Open Close Indica tor lamp Close gate Open gate ngineering Inc 230 Ryan Way South San Francisco CA 94080 6...

Страница 293: ...e way the room is used 8 6 1 Requirements for a lighting system The various luminous rows are switched on and off local ly If there is sufficient daylight the rows on the window side of the room are automatically switched off by means of a daylight control switch The lights are switched off automatically at 20 00 h Local manual operation of the lighting must be possible at all times Luminous rows ...

Страница 294: ...s to al low operation of the lights after they are switched off Components required Pushbuttons S1 to S4 Daylight control switch B1 Timer E1 Interval time delay relays K1 and K2 Pulse switches K3 to K6 with central OFF function Disadvantages of the previous solution A substantial amount of switchgear needs to be installed to implement the necessary functions Due to the large number of mechanical c...

Страница 295: ...B1 lx E5 S1 S2 S3 S4 I4 I5 I1 I2 I3 1 2 1 2 1 2 1 2 Luminous rows 1 Luminous rows 2 Luminous rows 3 Luminous rows 4 Components used S1 to S4 normally open contact momentary pushbutton B1 normally open contact daylight control switch ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 296: ...an install a smaller and space saving distribution cabinet Fewer devices are required The lighting system can be easily modified Additional switching times can be set as required se quential circuit for the off pulses at the end of the day The function of the daylight control switch can be easily applied to all lamps or to a modified group of lamps x T 1s I5 T 1s x I5 I1 I2 I3 I4 x x Off pulse tri...

Страница 297: ...d S1 S2 S3 S4 M1 K4 Rainwater supply line Drinking water supply line Pressure switch Control in the distribution box Pressure tank Pump Rainwater reservoir Drinking water supply Off Drinking water supply On Dry run protection Off Dry run protection On Service water connection The rainwater is collected in a reservoir From the reservoir a pumping station supplies a respective line system From there...

Страница 298: ...tion K1 K2 K3 S1 K3 S4 K3 L1 N K4 S3 K4 p K2 S3 S2 Y1 Auxiliary circuit Pump Tracking time Dry run protection Drinking water supply line The pump and a solenoid valve are controlled by means of a pressure switch and 3 float switches which are installed in the rainwater reservoir The pump must be switched on when the pressure level in the boiler drops below minimum After the operating pressure is r...

Страница 299: ...tor relay to switch the pump For single phase AC pump systems you must provide a contactor relay if the power consumption of the AC motor exceeds the capacity of the output relay Q1 The power consumption of a solenoid valve is usually low enough to allow direct controlling K1 contactor relay Y1 solenoid valve S1 normally open contact pressure switch S2 normally open contact float switch S3 normall...

Страница 300: ...ich can only be implemented in a conventional circuitry by add ing further switchgear e g Enabling the pump at specific times Indication of imminent or existing water shortage Reporting of system faults I2 Q2 I1 I3 I4 x T 20 s x Q1 I3 Pressure switch Float switch for dry run protection OFF Float switch for dry run protection ON Float switch for drin king water supply ON Float switch for drinking w...

Страница 301: ...at regular intervals or opens and closes the shut ters while you are on holiday Central heating IDEC SmartRelay runs the circulation pump only when water or heating is actually required Refrigerating systems IDEC SmartRelay can defrost refrigerating systems at regular intervals to save ener gy costs You can illuminate aquaria and terraria on a time de pendent basis Last not least you can Use commo...

Страница 302: ...elay Manual 292 Do you want more Info For more information about IDEC SmartRelay see our web page see the preface for the URL ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 303: ...al installation Vertical installation Low temperature to IEC 60068 2 1 High temperature to IEC 60068 2 2 0 55 C 0 55 C Storage shipping 40 C 70 C Relative humidity IEC 60068 2 30 From 10 to 95 no condensation Air pressure 795 1080 hPa Pollutants IEC 60068 2 42 IEC 60068 2 43 SO2 10 cm3 m3 4 days H2S 1 cm3 m3 4 days Ambient mechanical conditions Protection mode IP20 Vibrations IEC 60068 2 6 5 9 Hz ...

Страница 304: ...to FL1D H12RCC FL1D B12RCC IEC 61000 4 5 Severity 3 1 kV power lines symmetrical 2 kV power lines asymmetrical Safety to IEC VDE Clearance and creepage distance rating IEC 60664 IEC 61131 2 EN 50178 cULus to UL 508 CSA C22 2 No 142 With FL1D B12RCC FL1D H12RCC also VDE 0631 Fulfilled Insulation strength IEC 61131 2 Fulfilled Cycle time Cycle time per function 0 1 ms Startup Startup time at power u...

Страница 305: ...0 30 mA 10 20 mA 5 15 mA 5 10 mA Voltage failure buffering 100 V AC 240 V AC typ 10 ms typ 20ms typ 10 ms typ 20ms Power loss at 100 V AC 240 V AC 100 V DC 240 V DC 1 1 4 6W 2 4 6 W 0 5 2 9 W 1 2 3 6 W 1 1 3 5W 2 4 4 8 W 0 5 1 8 W 1 2 2 4 W Backup of the real time clock at 25 C typ 80 h Accuracy of the real time clock typ 2 s day Digital inputs Number 8 4 Electrical isolation No No Input voltage L...

Страница 306: ...utputs Electrical isolation Yes Yes Dielectric Strength between power input terminals and output terminals 2 500 V AC 1minute 500 V DC 1 minute 2 500 V AC 1minute 500 V DC 1 minute In groups of 1 1 Control of a digital input Yes Yes Continuous current Ith max 10 A per relay max 5 A per relay Surge current max 30 A max 30 A Incandescent lamp load 25000 switching cycles at 230 240 V AC 100 120 V AC ...

Страница 307: ...16 A characteristic B16 Minimum Switching Load 10 mA 12 V DC 10 mA 12 V DC Initial Contact Resistance 100 mΩmaximum at 1A 24V DC 100 mΩ maximum at 1A 24V DC Mechanical Life 10 000 000 operations minimum no load 10 Hz 10 000 000 operations minimum no load 10 Hz Electrical Life 100 000 operations minimum rated re sistive load 1800 operations hour 100 000 operations minimum rated re sistive load 1800...

Страница 308: ... Power loss at 24 V 0 7 1 3 W 0 8 1 1 W Backup of the real time clock at 25 C Accuracy of the real time clock Digital inputs Number 8 4 Electrical isolation No No Input voltage Signal 0 Signal 1 L 5 V DC 12 V DC L 5 V DC 12 V DC 1 Input current at Signal 0 Signal 1 0 85mA I1 I6 0 05 mA I7 I8 2 mA I1 I6 0 15 mA I7 I8 0 85mA 2 2 mA 3 Delay time at 0 to 1 1 to 0 typ 1 5 ms I1 I4 1 0 ms I5 I6 typ 1 5 ...

Страница 309: ...ion No No In groups of Control of a digital input Yes Yes Output voltage Supply voltage Supply voltage Output current max 0 3 A max 0 3 A Continuous current Ith Incandescent lamp load 25000 switching cycles at Fluorescent tubes with ballast 25000 switching cycles Fluorescent tubes conventionally compensated 25000 switching cycles Fluorescent tubes uncompen sated 25000 switching cycles Short circui...

Страница 310: ...ion 1 to 4 specifications For identifying the version see page 4 4 When FL1D H12SND or FL1B M08B1S2 are switched on signal 1 is sent to the digital outputs for about 50 microseconds Take this into account especially when using devices that react to short pulses 5 The maximum switching rate of the FL1D H12SND is only dependent on the switching program s cycle time FL1D H12SND FL1B M08B1S2 Note When...

Страница 311: ... 20 75 mA 40 100 mA 20 75 mA Voltage failure buffering typ 5 ms typ 5 ms Power loss 24 V AC 24 V DC 0 9 2 7 W 0 4 1 8 W 0 9 2 7 W 0 4 1 8 W Backup of the real time clock at 25 C typ 80 h Accuracy of the real time clock typ 2 s day Digital inputs Number 8 optional P action or N action 4 optional P action or N action Electrical isolation No No Input voltage Signal 0 Signal 1 L 5 V AC DC 12 V AC DC L...

Страница 312: ...ps of 1 1 Control of a digital input Yes Yes Output voltage Output current Continuous current Ith max 10 A per relay max 5 A per relay Surge current max 30A max 30A Incandescent lamp load 25000 switching cycles at 1000 W 1000 W Fluorescent tubes with ballast 25000 switching cycles 10 x 58 W 10 x 58 W Fluorescent tubes convention ally compensated 25000 switching cycles 1 x 58 W 1 x 58 W Fluorescent...

Страница 313: ...0 mΩmaximum at 1A 24V DC 100 mΩ maximum at 1A 24V DC Mechanical Life 10 000 000 operations minimum no load 10 Hz 10 000 000 operations minimum no load 10 Hz Electrical Life 100 000 operations minimum rated re sistive load 1800 op erations hour 100 000 operations minimum rated re sistive load 1800 op erations hour Switching rate Mechanical 10 Hz 10 Hz Electrical Ohmic load lamp load 2 Hz 2 Hz Induc...

Страница 314: ...ing 12 V DC 24 V DC typ 2 ms typ 5 ms typ 2 ms typ 5 ms Power loss 12 V DC 24 V DC 0 3 1 7 W 0 4 1 8 W 0 3 1 7 W 0 4 1 8 W Backup of the real time clock at 25 C typ 80 h Accuracy of the real time clock typ 2 s day Electrical isolation No No Digital inputs Number 8 4 Electrical isolation No No Input voltage L Signal 0 Signal 1 5 V DC 8 5 V DC 5 V DC 8 5 V DC 1 Input current at Signal 0 Signal 1 0 8...

Страница 315: ...0 m Error limit 1 5 of full scale Digital outputs Number 4 4 Output type Relay outputs Relay outputs Electrical isolation Yes Yes Dielectric Strength between power input terminals and output termials 2 500 V AC 1minute 500 V DC 1 minute 2 500 V AC 1minute 500 V DC 1 minute In groups of 1 1 Control of a digital input Yes Yes Output voltage Output current Continuous current Ith per ter minal max 10 ...

Страница 316: ... Short circuit proof cos 0 5 to 0 7 Power protection B16 900A Power protection B16 900A Parallel output circuits for power increase Not permitted Not permitted Protection of output relay if desired max 16 A characteristic B16 max 16 A characteristic B16 Minimum Switching Load 10 mA 12 V DC 10 mA 12 V DC Initial Contact Resistance 100 mΩmaximum at 1A 24V DC 100 mΩ maximum at 1A 24V DC Mechanical Li...

Страница 317: ... 5 specifications For identifying the version see page 4 FL1D H12RCE FL1D B12RCE FL1B M08B2R2 Note When connecting a fluorescent lamp to the output take the inrush current into consideration When the inrush current exceeds the rated value connect an ap propirate relay between the output and the fluorescent lamp ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670...

Страница 318: ...rs solenoid coils motors 0 1 0 2 0 3 0 4 0 5 2 4 6 8 10 Switching cycles million 12 24 V AC DC 100 120 V AC 230 240 V AC 120 V DC 240 V DC Switched current A Maximum 10 A Maximum 10 A Maximum 10 A Maximum 0 2 A Maximum 0 1 A 0 1 0 2 0 3 0 4 0 5 3 2 1 0 6 0 7 0 8 0 9 1 0 Switching cycles million 12 24 V AC DC 100 120 V AC 230 240 V AC 120 V DC 240 V DC Switched current A Maximum 2 A Maximum 3 A Max...

Страница 319: ...nal for connecting ground and shielding of the analog measuring line Analog inputs Number 2 Type Unipolar Input range 0 10 V DC input impedance 76 kΩ or 0 20 mA input impedance 250 Ω Resolution 10 bit normalized to 0 1000 Cycle time for analog value generation 50 ms Electrical isolation No Line length shielded and twisted 10 m Encoder supply voltage none Error limit 1 5 of full scale Interference ...

Страница 320: ...ing line Analog outputs Number 2 Input range 0 10 V DC Load resistor 5 kΩ Resolution 10 bit normalized to 0 1000 Cycle time for analog value output depending on installation typ 50 ms Electrical isolation No Line length shielded and twisted 10 m Error limit 2 5 of full scale Short circuit protection Yes Response at short circuit affected output 0 V neighboring output reverts Overload protection Ye...

Страница 321: ... This test program is created in IDEC SmartRelay and returns a value during its execution in parameter assignment mode from which the current cycle time is derived Test program 1 Create the test program by linking an output to a fre quency trigger and connecting the trigger input with an inverted marker 2 Configure the frequency trigger as shown below A pulse is generated in each program cycle due...

Страница 322: ...inverted marker block changes its output signal at each program execution Thus one logic level high or low width is exactly equivalent to the length of one cycle Hence a pe riod lasts 2 cycles The frequency trigger indicates the ratio of periods per 2 sec onds which results in the ratio of cycles per second 1 period 1 pulse 2 cycles Period Cycle time Edge transition of the inverted marker at each ...

Страница 323: ...more The versions without display offer you the following benefits Even more cost effective without the operating element Requires less switch cabinet space than conventional hardware Substantial benefits with regard to flexibility and prime costs compared to stand alone electronic switchgear Of advantage even for applications in which merely two or three conventional switching devices can be repl...

Страница 324: ...d by means of buttons This is why the FL1D B12 versions have other startup characteristics Startup characteristics If there is no circuit program in the IDEC SmartRelay or on the inserted memory cartridge card IDEC SmartRelay re mains in STOP If there is a valid circuit program in IDEC SmartRelay mem ory the IDEC SmartRelay automatically switches from STOP to RUN when power is switched on The circ...

Страница 325: ...ent data WindLGC see Chapter 7 provides an online test for reading the current data of all functions while the system is in RUN If your IDEC SmartRelay without display holds a protected memory cartridge card you can not read the current data unless you enter the correct password for your the circuit program The circuit program is otherwise deleted from IDEC SmartRelay memory when you remove the me...

Страница 326: ...nt menu Parameter setting Chapter 5 1 1 cont Default values setting Chapter 5 2 cont Display of the program name See Main menu Main menu ESC Stop See Programming menu See Transfer menu See Setup menu See Start menu Programming menu ESC Stop Program Editing the program Chapter 3 6 cont Deleting the program Chapter 3 6 12 Input change of pass word Chapter 3 6 5 Editing the program name Chapter 3 6 4...

Страница 327: ...hapter 6 3 Copying the program from the memory cartridge card to IDEC SmartRelay Chapter 6 4 Setting the program copy protection Chapter 6 1 Setup menu ESC Stop Setup Setting the time date Chapter 5 2 1 Setting the summertime wintertime Chapter 3 6 13 Cannot be used Start menu RUN max 10 message texts Date time Inputs Outputs Memory Markers Cursor keys Parameter assignment menu Setting the display...

Страница 328: ... 240V AC DC 8 4 Yes Yes FL1D B12RCC FL1D H12RCA 24V AC DC 8 4 Yes Yes FL1D B12RCA FL1D H12RCE 12 24V DC 8 I1 I8 2 I7 I8 4 Yes Yes FL1D B12RCE FL1D H12SND 24V DC 8 I1 I8 2 I7 I8 4 Tr Yes Expansion Module FL1B M08B2R2 12 24V DC 4 4 FL1B M08B1S2 24V DC 4 4 Tr FL1B M08C2R2 100 240V AC DC 4 4 FL1B M08D2R2 24V AC DC 4 4 FL1B J2B2 12 24V DC 2 FL1D K2B2 24V DC 2 AS Inter face Module FL1B CAS2 AS Interface...

Страница 329: ... incl Hardware Software Manual FL9Y LP1CDW PC Cable Down load Up load Cable FL1A PC1 Memory cartridge Brown FL1C PM3 User s Manual FL1D User s Manual English FL9Y B966 Mounting Clip 5 pieces FL1B PSP1PN05 Removal Tool Memory Cartridge Removal Tool MT 101 ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...

Страница 330: ...tion 115 NAND 116 NAND with Edge Detection 117 NOR 119 NOT 120 OR 118 XOR 120 blank outputs 55 110 Block deleting 91 block groups 92 inserting 85 number 57 assigning 58 BN 108 C Cap 20 Card See memory cartridge card CE label 12 Certification 11 Character set 75 Circuit diagram 60 Circuit program 102 deleting 95 input 69 Circuit program name assigning 75 Circuit programs archiving 241 reproduce 241...

Страница 331: ...9 Display 58 Display contrast 239 Disposal 12 DM See Digital module Dual function switch 154 E Earth connection 28 Edge detection 115 117 Edge triggered interval time delay relay 144 Editing 85 Example Air conditioning system 270 Automatic door 263 Factory door 275 factory door controlling 279 monitoring 279 lighting corridor 259 stairway 259 Luminous rows 283 Service water pump 287 exclusive OR 1...

Страница 332: ... relay edge triggered 144 Internet address ii Interpulse width 148 Interval time delay relay Pulse out put 142 Inverter 120 L Latching relay 195 LCD 4 5 LED 315 Levels 111 List BN 108 Co 108 109 GF 108 112 SF 108 Logic module 1 Logical inputs 122 M Memory areas 102 free 107 limitation 102 requirements 104 space 102 Memory cartridge card CopyProtect 244 IDEC SmartRelay Card 248 copying 250 Enabling...

Страница 333: ...ics 314 Status indication 315 Operating hours counter 169 Reading the MN and OT values 172 Operating mode Changing the operating mode 63 Programming mode 66 OR 118 Outputs 110 blank 55 110 connecting 40 Digital outputs 110 P Parameter 232 Set Param 231 Inputs 122 selecting 233 setting 229 T 123 Parameter assignment 87 Parameter assignment menu 65 230 Parameter assignment screen form 158 201 Parame...

Страница 334: ...Characteristics 29 Sensor connections 34 Set Set 238 Setting Default values 237 Display contrast 239 Start screen 240 time 88 Time of day and date 237 Setting the date 237 Setting the time of date 237 Setting the time of day 237 Settings Set 231 Seven day time switch 157 159 Examples 160 setting 159 SF 108 128 Shift register 210 Shift register bits 55 111 Showing 88 Signal status transitions 32 Si...

Страница 335: ...Clock 96 disabling 100 enabling 97 user define parameters 99 Switch Dual function switch 154 Seven day time switch 157 Stairwell Light Switch 151 Twelve month time switch 162 Switched current maximum 41 Symbols 8 Synchronization 101 Sync 101 Clock 101 enabling 101 T T Parameter 123 Technical data 293 FL1B J2B2 309 FL1B M08B1S2 298 FL1B M08B2R2 304 FL1B M08C2R2 295 FL1B M08D2R2 301 FL1D B12RCA 301 ...

Страница 336: ... USB 255 V Verification 89 Voltage levels 111 Voltage supply connecting Circuit protection 28 W Weekday 158 WindLGC 253 Wintertime 96 Wire ferrules 26 without display 313 creating a circuit program 52 PC IDEC SmartRelay mode 255 reading current data 315 X XOR 120 ngineering Inc 230 Ryan Way South San Francisco CA 94080 6370 General Inquiries 800 670 4183 www ste ...