70
HS5E-K Interlock Switches with Key
Logic Circuit using FS1A Safety Controller
Example 1: Hostage control (one robot)
Turn the key selector switch to Teach Mode and remove the key . Unlock HS5E-K using the same key, then remove the key
and open the door to enter .
Gripping the enabling switch in the enabling position enables the robot to operate .
FS1A-C11S
LOGIC13A
Emergency
Stop Switch
Emergency
Stop Switch
HE2G
Grip Switch
HW Series
Key Selector
Switch
(Pin Tumber
Type)
HS5E-K
Key Interlock
Switch
>=1
Safety Input 1
T0, X0, X1
Teach Mode
Auto Mode
Control
Safety Input 2
T2, X2, T3, X3
Safety Input 6
T12, X12,
T13, X13
Safety Input 5
T10, X10,
T11, X11
Safety Input 4
T6, X6, T7, X7
Safety Input 3
T4, X4, T5, X5
Start Input 1
X16
Start Input 2
X17
External Device Monitor 1
T14, X14
Monitor Input
Monitor Input
External
Device
Monitor
Self-hold function circuit 1
Mode Select
II
Hold
Trigger
Self-hold
function
Self-hold function circuit 2
Y0
Y1
Y2
Y3
Safety Output 1
Safety Output 2
Hold
EDM
Hold
EDM
Self-hold function circuit 3
Hold
Trigger
Self-hold
function
Hold
Trigger
Self-hold
function
&
&
&
&
Dual Channel
Direct Opening
Dual Channel
Direct Opening
Dual Channel
Dependent
Dual Channel
Dependent
Dual Channel
Dependent
Control
Start
EDM
EDM
External Device Monitor 2
T15, X15
OSSD
with
Off-delay
OSSD
External
Device
Monitor