Service (Qualified personnel only; continued)
Replacement Guide
Adjustments Clamp Stop
2. Remove old wire guide and insert new wire
guide, making sure that the cross slot of
each bushing faces downward.
If the wire guides have all been
removed it may be necessary
to spread the wire guide clamp
“slightly” to install the
first bushing. It is not
recommended to spread or
separate the wire guide clamp
any more than necessary
during installation.
3. Relocate retaining plate (Item 13)*
and thumb screw (Item 14)*.
1. Remove the guide
retaining plate (Item 13)*
by removing the thumb
screw (Item 14)*.
Adjustments Partial Strip
Cross slot at bottom position
It may become necessary to adjust the gripping action to increase or
decrease the gripping force. This unit is factory preset to increase or
decrease the grip with full force. Softer insulations may require less force
to minimize deformation.
1. Disconnect unit from air and power supply.
2. Remove face place (use 7/64 hex wrench).
3. Raise or lower set screws evenly (use 1/16 hex wrench). This will
allow for an increase or decrease in the gripping force of the bush-
ings.
4. Replace face plate.
NOTE: One clamp stop setting may not permit satisfactory gripping on dif-
ferent wires, due to the variety of wire types and gripping requirements.
B A
It may be desired to allow the stripped slug to remain on the wire to protect the con-
ductor during handling. The unit is factory preset to remove the slug completely. In
this initial position, the unit automatically actuates an air blasting device to aid in slug
removal. When a partial strip is set, the air blast is disarmed.
1. Disconnect air and power supply.
2. Remove slug tray and invert unit.
3. Loosen Socket head cap screw (A) (use 5/32 hex wrench) and reposition basket
stop pin (B) to obtain the desired
strip length.
4. Tighten Socket head cap screw to ensure basket stop pin is secure. Strip wire
to verify partial strip. Dissimilar wires will behave differently when stripped.
Therefore, it may be necessary to change the partial strip adjustment.
5. Turn the unit upright and insert the slug tray.
7