background image

Service (Qualified personnel only; continued)

Replacement Guide

Adjustments Clamp Stop

2.   Remove old wire guide and insert new wire 

guide, making sure that the cross slot of 
each bushing faces downward.

If the wire guides have all been 
removed it may be necessary 
to spread the wire guide clamp 
“slightly” to install the 
first bushing. It is not 
recommended to spread or 
separate the wire guide clamp 
any more than necessary 
during installation.

3.   Relocate retaining plate (Item 13)*  

and thumb screw (Item 14)*.

1.  Remove the guide 
 

retaining plate (Item 13)* 
by removing the thumb 
screw (Item 14)*.

Adjustments Partial Strip

Cross slot at bottom position

It may become necessary to adjust the gripping action to increase or 
decrease the gripping force. This unit is factory preset to increase or 
decrease the grip with full force. Softer insulations may require less force 
to minimize deformation.
1.    Disconnect unit from air and power supply.
2.    Remove face place (use 7/64 hex wrench). 
3.    Raise or lower set screws evenly (use 1/16 hex wrench). This will 

allow for an increase or decrease in the gripping force of the bush-
ings. 

4.    Replace face plate.
NOTE: One clamp stop setting may not permit satisfactory gripping on dif-
ferent wires,  due to the variety of wire types and gripping requirements.

B                 A

It may be desired to allow the stripped slug to remain on the wire to protect the con-
ductor during handling. The unit is factory preset to remove the slug completely. In 
this initial position, the unit automatically actuates an air blasting device to aid in slug 
removal. When a partial strip is set, the air blast is disarmed.
1.    Disconnect air and power supply.
2.    Remove slug tray and invert unit. 
3.    Loosen Socket head cap screw (A) (use 5/32 hex wrench) and reposition basket 

stop pin (B) to obtain the desired  
strip length.

4.    Tighten Socket head cap screw to ensure basket stop pin is secure. Strip wire 

to verify partial strip. Dissimilar wires will behave differently when stripped. 
Therefore, it may be necessary to change the partial strip adjustment.

5.    Turn the unit upright  and insert the slug tray.

7

Содержание Stripmaster 950

Страница 1: ...45 950 45 954 45 950 1 Stripmaster Model 950 Model 954 Wire Stripper...

Страница 2: ...y 4 Strip Length 5 Service Replacement Adjustment 6 Replacement Guide 7 Adjustments Clamp Stop 7 Adjustments Partial Strip 7 Circuit Board Adjustment 8 Stripmaster Model 950 950 1 Alignment Adjustment...

Страница 3: ...ries not recommended by IDEAL Technical Data Strip Lengths Minimum 125 inches 3mm Maximum 63 inches 16mm Strip Capacity Minimum 30 AWG 05mm2 Maximum 10 AWG 6 0mm2 Accuracy Meets Military specification...

Страница 4: ...locate the regulator in the mounting bracket and replace the retaining nut securely Thermal Head Rotation Speed 4 Connect the air line to a clean dry regulated air supply Air pressure must be regulate...

Страница 5: ...ength turn machine to its upright position and turn power switch on Strip several sample wires and verify proper strip lengths Repeat strip length adjustments as required CAUTION Strip length range is...

Страница 6: ...ly adjusted tighten all blade holding screws 10 Reconnect air line to the face plate by inserting hose into the com pression fitting firmly 11 Reinstall front cover plate making sure clamp dowel pins...

Страница 7: ...e place use 7 64 hex wrench 3 Raise or lower set screws evenly use 1 16 hex wrench This will allow for an increase or decrease in the gripping force of the bush ings 4 Replace face plate NOTE One clam...

Страница 8: ...crewdriver Clockwise to increase delay and counterclockwise to reduce delay 3 Cycle the machine and continue to readjust as required 4 Replace top plate It may be desired to increase the time delay af...

Страница 9: ...raise or lower all six blades to their proper vertical position if needed Adjust both sides evenly 4 Install slug tray and top plate Adjustment Horizontal 1 Remove slug tray 2 Close blades using set u...

Страница 10: ...t screws use 3 32 hex wrench reposition the carriage left or right to obtain the proper alignment 4 Install slug tray Adjustments Permanent Faceplate Clamp Bar 1 With air connected to machines turn po...

Страница 11: ...cle n Empty the slug removal tray and make sure that all slugs have been removed from the unit n Disconnect the unit from the air and power supply and check to see that no insulation slugs are trapped...

Страница 12: ...sed with each wire type and size Due to varying outside diameter dimensions on every wire IDEAL recommends ordering multiple wire guide bushings to match a given wire Depending upon wire tolerances it...

Страница 13: ...2472 16 6 TRIGGER ASSEMBLY LB1526RP 17 5 SCREW 4 40 X 25 PH NYLON 358 033 ITEM REQ NAME PART NO 18 4 WASHER 4 NYLON 637 006 19 1 CONTACT PLATE LB1504 20 1 CUT YOKE K 6806 21 1 SLUG TRAY ASSEMBLY K 711...

Страница 14: ...Notes...

Страница 15: ...Notes...

Страница 16: ...rington Cheshire WA5 5TN England 44 1925 444 446 www idealind com Warranty limited solely to repair or replacement no warranty of merchantability fitness for a particular purpose or consequential dama...

Отзывы: