INSTALLATION
36 STANDARD CONTROLS ACCESS
Modes of Operation
The standby, parameter and information modes are accessible without the service code.
Standby Mode
The standby mode will be shown after start up or reset of the boiler control module. If no buttons are pressed for 20 minutes
the display will automatically be set to standby mode. If new parameters have been stored they will then become active.
Parameter Mode
In parameter mode it is possible to change the settings of the boiler control module. The following settings can be changed.
1. DHW Temperature
2. DHW System
3. CH System
4. Flow Temperature (T1)
Parameter settings and limits are listed below.
Parameter mode is entered from standby mode by pressing the 'mode' button once.
S t b y
P A R A
Press the 'step' button until the desired parameter is displayed.
Press the '+' or '-' buttons to change the values.
The parameter setting can be stored by pressing and releasing the 'store' button, the new setting flashes twice to show it has
been accepted. The new setting will become active when the 'mode' button is pressed or if the display is left. If the display is
left, after 20 minutes it automatically returns to 'standby' mode.
P A R A
Press
Display
DHW Temperature (ºC)
Instant water heater
40
65
Storage Tank
20
70
60
Press
Display
Factory
Setting
Upper
Limit
Lower
Limit
Description
DHW System
00 = Off
01
01 = On
02 = Off + pump continuous
03 = On + pump continuous
1. 6 0
2. 0 1
CH System
00 = Off
01 = On
01
02 = Off + pump continuous
03 = On + pump continuous
3. 0 1
CH Flow Temperature (ºC)
20
90
82
4. 8 2
INST
ALLA
TION