16 HANDLE REMOVAL FOR CARTRIDGE ACCESS
17 THERMOSTATIC CARTRIDGE REPLACEMENT
18 DIVERTER REPLACEMENT OF A7543AA
23
max.
5 Nm
Cartridge
stop
Align
Align
32
1.
Observe disassembling sequence, as detailed in
section 14, steps 1 to 3.
2.
Remove the flow diverter handle (right side) as detailed in
section 16.
Remove also the drive bush fitted to the spindle
of the diverter cartridge. Note: the square end cap can remain
inside the mixer body.
3
. Slide off the stop sleeve.
Use the following method to inspect or replace the thermostatic cartridge:
1.
Observe the disassembling sequence,
see section 14, steps 1 to 3.
2.
Remove the temperature control handle (left side) as detailed in
section 16.
Remove also the drive
bush fitted to the spindle of the thermostat. Note: the square end cap can remain inside the mixer body.
3.
Using a 32mm spanner or socket, undo the large nut retaining the thermostatic cartridge.
The cartridge should now slide out of the mixer’s bore. Note: the nut is captivated onto the cartridge
& will rotate freely.
4.
If necessary, replace the cartridge with a new one. Alternatively, if the cartridge is functioning correctly,
clean it thoroughly & reuse it.
5.
When fitting the cartridge into the bore, ensure the lug on the cartidge is orientated into the cut out in
the mixer’s bore, as illustration above.
6.
Make sure the marking on the spline of the cartridge spindle is aligned with the edge of the „stop“ as
illustration above. Correct the alignment if necessary.
7.
With the cartridge located back in the mixer bore, screw the cartridge nut into the mixer body by
hand & then tighten with a spanner or socket. Do not exceed 5 Nm torque.
8.
Reverse the sequence to refit the drive bush & handle. Check & adjust the 40°C position as shown
in section 8. Ensure correct alignment of the handle as detailed in section 16.
4.
Using a 28mm spanner or socket, undo the threaded collar & slide out. The diverter cartridge should
now slide out of the mixer’s bore complete with O-ring.
5.
If necessary, replace the cartridge with a new one. Alternatively, if the cartridge is functioning correctly,
clean it thoroughly & reuse it.
6.
Rotate the diverter cartridge spindle fully clockwise until it stops. Looking at the cartridge from the
underside, the left port should be closed as illustrated. Maintain this orientation of the diverter & slide
it into the mixer body. Note: the two locator pins on the front face of the diverter cartridge are different
sizes to prevent incorrect installation. Ensure these pins are correctly located into the plastic moulding
inside the mixer body.