background image

20  CHECK-VALVE REPLACEMENT

25

1.

 Demount the mixer body from the wall, as detailed in section 15, follow steps 1 to 4.

2.

 Locate the sealing washers (with integral strainers) from inside the mixer’s inlet bores & keep

    them in a safe location.

3

. The check valves are housed inside the retaining inserts within the inlet bores. Look closely at

    the rear of the mixer body.

4.

 Note: circlips hold the check valves in position. Using circlip pliers, squeeze the circlip & lift it away

    from the bore.

5.

 Gently pull out the check valves: inspect & clean or replace if necessary. Observe the flow direction

    arrow on the body of the check valve as shown above. Refit the circlips.

6. To refit the mixer to the wall reverse this procedure (remember to fit the sealing washers).

1.

 Remove the flow control handle (right side) as detailed in 

section 16.

 Remove also the drive bush

    fitted to the spindle of the flow cartridge. Note: the square end cap can remain inside the mixer body.

2.

 Slide off the stop ring.

3.

 Using a 17mm spanner or socket, undo the flow cartridge. The cartridge should now slide out of the

    mixer’s bore.

4.

 If necessary, replace the cartridge with a new one. Alternatively, if the cartridge is functioning correctly,

    clean it thoroughly & reuse it. 

5.

 With the cartridge located back in the mixer bore, screw the cartridge into the mixer body by 

    hand & then tighten with a spanner or socket. Ideally torque to 16Nm min to 18Nm max.

6.

 Refit the stop ring as illustrated above. Align the marked arrow on the stop ring to the front top corner

    of the mixer body or use the marker on the square end cap as guidance.

7.

 Rotate the cartridge spindle fully clockwise until it stops.

8.

 Reverse the sequence to refit the drive bush & handle. Check & adjust the off position as shown

    in 

section 8

. Ensure correct alignment of the handle as detailed in 

section 16.

IMPORTANT: 

Although the check valves can be replaced, they 

must not be removed

 

completely. Do not operate the mixer without BOTH the check valves correctly fitted.

Observe flow 

direction

Strainer 

washers

Содержание Ceratherm C100 A7537AA

Страница 1: ...c Bar Shower Mixer supplied over head shower handset kit Ceratherm C100 Exposed Thermostatic Bar Shower Mixers INSTALLER After installation please pass this instruction booklet to user IMPORTANT BEFOR...

Страница 2: ...ISSIONING PERIODIC CHECKS 18 11 FREQUENCY OF REGULAR SERVICING 18 12 COLD WATER ISOLATION CWI TEST 19 13 MAINTENANCE NOTES 19 14 DISASSEMBLY SEQUENCE OF MAINTENANCE 20 15 DEMOUNTING THE MIXER FOR DISI...

Страница 3: ...5 G 1 2 65 300 1122 min 700 79 5 74 381 5 23 30 x 15 50 2 L 1750 180 58 3 Basic shower valve dimensions shown with mounting brackets assembled Shower kit overhead shower supplied with A7543AA 600 Show...

Страница 4: ...square overhead shower plate 1750 shower hose slim shower hand set A7543AA Shower valve without mounting brackets A7537AA 600 Shower kit includes 600 riser rail a pair of mounting brackets sliding br...

Страница 5: ...d as the vertical distance between the bottom of the cold water storage tank which feeds the hot water system and the highest point on the shower spray plate When installing with a shower pump the use...

Страница 6: ...ervice valves for isolating both water supplies MUST be fitted below the bath to permit future maintenance of this product see sect 23 These should be fitted as close as practicable to the water suppl...

Страница 7: ...ted zone of backflow risk for restrained hose which is longer than system design hose not permitted zone of backflow risk for unrestrained hose zone of backflow risk for restrained hose w c spill over...

Страница 8: ...lose as practicable to the water supply inlets of the mixer in an easily accessible location NOTE service valves are not supplied with thiese products see section 23 Shower Kit Each product is supplie...

Страница 9: ...ply pipes should be run within the wall cavity Hot supply pipe should be on the left hand side and the cold on the right Ensure that the hot and cold pipes are positioned 150mm apart and are level Use...

Страница 10: ...aging conce aled pipework 10 MIN 20 MAX With the wall brackets in position the supply pipes should be trimmed as shown The pipes should project from the front face of the brackets by bet ween 10 to 20...

Страница 11: ...ternate to ensure mixer remains parallel to the wall O rings can be wetted with water to help them slide Fit the O rings provided into the grooves of the escutcheon Tighten the coupling nuts as far as...

Страница 12: ...tighten the two grub screws visible from the rear of the wall bracket This will secure the wall bracket to the riser rail 3 This assembly of the shower rail parts together can now be located onto the...

Страница 13: ...centrally within the square orientate it as shown Mark the two slot positions on the wall 7 Drill two 6mm holes into the wall at the centre of the marked slots 8 Tap two wall plugs into the two drille...

Страница 14: ...hower handset The flexible shower hose has integral seals at both ends The shower handset can be parked in the bracket using the conical portion of the shower hose as shown The shower parking bracket...

Страница 15: ...t 2 Tap a wall plug into the 6mm drilled hole 3 Using a posi screw driver the screw pro vided securely fix the bracket to the wall 5 Example of a completed installation 4a Ensure the shower hose is tr...

Страница 16: ...ition Rotating this handle downwards from the parked position commences water flow By rotating the handle 90 from the off position the user will encounter economy flow stop delivering about 50 of the...

Страница 17: ...e further to the maximum flow stop Rotating this handle upwards from the parked position commences water flow will direct water to the top outlet This will activate the large overhead shower plate At...

Страница 18: ...low 45 C If there is no significant change to the set outlet temperature 2 C or less change from the original settings and the fail safe shut off is functioning then the valve is working correctly and...

Страница 19: ...clean all filters ensure check valves are working and make sure all isolating valves are fully open Refit the shower handset to the flexible hose upon completion of the test NOTE In order to isolate t...

Страница 20: ...Use inline service valves if fitted 2 Fully open the flow or diverter handle to confirm water is switched off Unscrew the shower hose from the underside of the mixer This will permit some of the trap...

Страница 21: ...ely dependent upon the water quality and service life As a minimum we recommend removal both handles thermostatic cartridge flow control or diverter cartridge Cleaning the cartridge strainer screens i...

Страница 22: ...h 4 The drive bush can be removed if necessary by undoing the Phillips screw shown using a suitable screw driver 5 If necessary the square end caps fitted at each end of the mixer body can be removed...

Страница 23: ...bore ensure the lug on the cartidge is orientated into the cut out in the mixer s bore as illustration above 6 Make sure the marking on the spline of the cartridge spindle is aligned with the edge of...

Страница 24: ...9 Reverse the sequence to refit the drive bush handle Align the button edge of the handle to the rear edge of the mixer body overhead shower fully open fit screw roatate handle 90 back to the off posi...

Страница 25: ...cap can remain inside the mixer body 2 Slide off the stop ring 3 Using a 17mm spanner or socket undo the flow cartridge The cartridge should now slide out of the mixer s bore 4 If necessary replace t...

Страница 26: ...NU 1 Set 6 Non return valve A 861 372 NU 1 Set 7 Shower bracket cpl A 861 548 AA 2 Set 8 Shower hose 1750 mm A 4109 AA 1 pcs 9 Handspray 3Func 110 B 2232 AA 1 pcs 10 Slider holder f handshr B 961 024...

Страница 27: ...7 Shower bracket cpl A 861 548 AA 2 Set 8 Connection nipple cpl A 861 550 NU 1 Set 5 1 2 1 3 4 9 15 10 13 11 12 14 8 9 7 6 A7543AA Ceratherm C100 Exposed Thermostatic Bar Shower Mixer supplied over h...

Страница 28: ...se as is practicable to the water supply inlets of the thermostatic shower valve Service valves should be installed in an easily accessible location Basic valve with isolating only feature is availabl...

Отзывы: