background image

21

  Method for demounting mixer:

1. 

Observe disassembling sequence, as detailed in 

section 14, steps 1 & 2.

2. 

Remove the overhead shower assembly, if fitted (A7543AA only).

3. 

Slide back both escutcheons away from the wall towards the mixer body. Undo the two coupling nuts

    located at the rear of the mixer (see fig above). Take care not to lose the two sealing /strainer washers.

4. 

Lift the mixer body off from the wall mount brackets, by gently pulling away as shown.

5. 

The mixer body can be further dismantled for cleaning protocols. Do not leave the wall mount

    brackets uncovered for long periods, protect from environmental contamination.

6. 

To refit the mixer body; reverse this procedure. Tighten the nuts at the rear of the mixer securely.

Disinfection method

Disinfection by full immersion in an appropriate bactericidal solution is recommended for this assembly. 

Prior to immersion, the mixer body should be clean and dismantled to a level that prevents air locking.

The level of dismantling should be established as a result of practice and will be largely dependent upon 

the water quality and service life. As a minimum we recommend removal both handles, thermostatic 

cartridge & flow-control (or diverter) cartridge. Cleaning the cartridge strainer screens is important. All 

components can be immersed together unassembled.

Disinfected mixers should be promptly replaced or stored using an appropriate method until required.

Disinfection frequency

The frequency of such disinfection actions will be derived from regular sampling carried out under the 

regime of the Responsible Person (Water). We would not expect to need greater than 6 monthly fre- 

quencies, hopefully considerably less.

The need for excessive use of this procedure would be indicative of the need for some root cause analy-

sis as there could be some system or behavioural problems that need addressing.

Recommended Disinfection Solutions

For immersion we recommend the use of a 70% Ethanol solution for 10 minutes.

NB: counter intuitively, 

greater than recommended concentrations are less effective

 not more effec

-

tive; take care to get the recommended concentration in line with the manufactures recommendation. 

DO NOT USE SOLUTIONS CONTAINING AMMONIA.

30

Avoid damaging the inlet seals. See sections 21 & 22 for replacement strainer washers.

Содержание Ceratherm C100 A7537AA

Страница 1: ...c Bar Shower Mixer supplied over head shower handset kit Ceratherm C100 Exposed Thermostatic Bar Shower Mixers INSTALLER After installation please pass this instruction booklet to user IMPORTANT BEFOR...

Страница 2: ...ISSIONING PERIODIC CHECKS 18 11 FREQUENCY OF REGULAR SERVICING 18 12 COLD WATER ISOLATION CWI TEST 19 13 MAINTENANCE NOTES 19 14 DISASSEMBLY SEQUENCE OF MAINTENANCE 20 15 DEMOUNTING THE MIXER FOR DISI...

Страница 3: ...5 G 1 2 65 300 1122 min 700 79 5 74 381 5 23 30 x 15 50 2 L 1750 180 58 3 Basic shower valve dimensions shown with mounting brackets assembled Shower kit overhead shower supplied with A7543AA 600 Show...

Страница 4: ...square overhead shower plate 1750 shower hose slim shower hand set A7543AA Shower valve without mounting brackets A7537AA 600 Shower kit includes 600 riser rail a pair of mounting brackets sliding br...

Страница 5: ...d as the vertical distance between the bottom of the cold water storage tank which feeds the hot water system and the highest point on the shower spray plate When installing with a shower pump the use...

Страница 6: ...ervice valves for isolating both water supplies MUST be fitted below the bath to permit future maintenance of this product see sect 23 These should be fitted as close as practicable to the water suppl...

Страница 7: ...ted zone of backflow risk for restrained hose which is longer than system design hose not permitted zone of backflow risk for unrestrained hose zone of backflow risk for restrained hose w c spill over...

Страница 8: ...lose as practicable to the water supply inlets of the mixer in an easily accessible location NOTE service valves are not supplied with thiese products see section 23 Shower Kit Each product is supplie...

Страница 9: ...ply pipes should be run within the wall cavity Hot supply pipe should be on the left hand side and the cold on the right Ensure that the hot and cold pipes are positioned 150mm apart and are level Use...

Страница 10: ...aging conce aled pipework 10 MIN 20 MAX With the wall brackets in position the supply pipes should be trimmed as shown The pipes should project from the front face of the brackets by bet ween 10 to 20...

Страница 11: ...ternate to ensure mixer remains parallel to the wall O rings can be wetted with water to help them slide Fit the O rings provided into the grooves of the escutcheon Tighten the coupling nuts as far as...

Страница 12: ...tighten the two grub screws visible from the rear of the wall bracket This will secure the wall bracket to the riser rail 3 This assembly of the shower rail parts together can now be located onto the...

Страница 13: ...centrally within the square orientate it as shown Mark the two slot positions on the wall 7 Drill two 6mm holes into the wall at the centre of the marked slots 8 Tap two wall plugs into the two drille...

Страница 14: ...hower handset The flexible shower hose has integral seals at both ends The shower handset can be parked in the bracket using the conical portion of the shower hose as shown The shower parking bracket...

Страница 15: ...t 2 Tap a wall plug into the 6mm drilled hole 3 Using a posi screw driver the screw pro vided securely fix the bracket to the wall 5 Example of a completed installation 4a Ensure the shower hose is tr...

Страница 16: ...ition Rotating this handle downwards from the parked position commences water flow By rotating the handle 90 from the off position the user will encounter economy flow stop delivering about 50 of the...

Страница 17: ...e further to the maximum flow stop Rotating this handle upwards from the parked position commences water flow will direct water to the top outlet This will activate the large overhead shower plate At...

Страница 18: ...low 45 C If there is no significant change to the set outlet temperature 2 C or less change from the original settings and the fail safe shut off is functioning then the valve is working correctly and...

Страница 19: ...clean all filters ensure check valves are working and make sure all isolating valves are fully open Refit the shower handset to the flexible hose upon completion of the test NOTE In order to isolate t...

Страница 20: ...Use inline service valves if fitted 2 Fully open the flow or diverter handle to confirm water is switched off Unscrew the shower hose from the underside of the mixer This will permit some of the trap...

Страница 21: ...ely dependent upon the water quality and service life As a minimum we recommend removal both handles thermostatic cartridge flow control or diverter cartridge Cleaning the cartridge strainer screens i...

Страница 22: ...h 4 The drive bush can be removed if necessary by undoing the Phillips screw shown using a suitable screw driver 5 If necessary the square end caps fitted at each end of the mixer body can be removed...

Страница 23: ...bore ensure the lug on the cartidge is orientated into the cut out in the mixer s bore as illustration above 6 Make sure the marking on the spline of the cartridge spindle is aligned with the edge of...

Страница 24: ...9 Reverse the sequence to refit the drive bush handle Align the button edge of the handle to the rear edge of the mixer body overhead shower fully open fit screw roatate handle 90 back to the off posi...

Страница 25: ...cap can remain inside the mixer body 2 Slide off the stop ring 3 Using a 17mm spanner or socket undo the flow cartridge The cartridge should now slide out of the mixer s bore 4 If necessary replace t...

Страница 26: ...NU 1 Set 6 Non return valve A 861 372 NU 1 Set 7 Shower bracket cpl A 861 548 AA 2 Set 8 Shower hose 1750 mm A 4109 AA 1 pcs 9 Handspray 3Func 110 B 2232 AA 1 pcs 10 Slider holder f handshr B 961 024...

Страница 27: ...7 Shower bracket cpl A 861 548 AA 2 Set 8 Connection nipple cpl A 861 550 NU 1 Set 5 1 2 1 3 4 9 15 10 13 11 12 14 8 9 7 6 A7543AA Ceratherm C100 Exposed Thermostatic Bar Shower Mixer supplied over h...

Страница 28: ...se as is practicable to the water supply inlets of the thermostatic shower valve Service valves should be installed in an easily accessible location Basic valve with isolating only feature is availabl...

Отзывы: