43
Installation and Servicing
Section 3 - Servicing
SER
VICING
3.16 GAS CONTROL VALVE REPLACEMENT
1. Disconnect and remove the trap and rubber connector.
2. Unplug the electrical lead connection from the gas control
valve.
3. Remove the outlet gas valve clip and slide the pipe
upwards.
4. Undo the gas inlet pipe union at the inlet to the gas valve.
5. Undo the two screws fixing the gas valve to the chassis
base and lift the gas valve upwards.
6. Fit the new gas control valve ensuring that the ‘o’ ring
and sealing washer are in place and reconnect gas and
electrical connections.
7. Refit the trap and fill.
8. Ensure all gas valve connections are gas tight with a gas
soundness check up to the gas control valve.
Refer to Section
3.2
Refer to Section
3.19
3
5
3.17 DIVERTER VALVE ACTUATOR REPLACEMENT
Refer to Section
3.2
Note.
All spares will be delivered in mid-position.
Refer to Section
3.10
To remove the motor:
1. Remove the condensate trap.
2. Press Down on the hot keys until the diverter valve mid
position is highlighted. Ensure that the diverter valve is in
mid position.
3. Place a flat bladed screwdriver in the actuator slot
provided and ease out the actuator.
4. Disconnect the electrical plug from the motor.
5. Fit the new motor ensuring the arm is correctly
engaged in the metal fork and reassemble ensuring the
condensate trap is refilled with water.
6. Reconnect the electrical plug to the motor.
Содержание LOGIC COMBI2 C24
Страница 62: ...62 Installation and Servicing Section 6 Benchmark to Commissioning ...
Страница 68: ...68 Notes Installation and Servicing ...
Страница 69: ...69 Notes Installation and Servicing ...