MAINTENANCE
Harrier GT Range
- Installation
17
• Maintenance of the combustion chamber
- open the combustion chamber door (lower door) by
unscrewing the 4 lock nuts (spanner 17),
- brush the inside of the combustion chamber,
- using a vacuum cleaner, vacuum up the soot deposits
accumulated in the combustion chamber,
- close the door and replace the front cover.
9.1 BOILER (continued)
Baffles
Harrier GT 5
Harrier GT 6
Harrier GT 7
Harrier GT 8
Harrier GT 9
Upper
lg 410
8
8
lg 570
4
4
4
Lower
lg 412
4
lg 572
2
2
2
2