ClearMark™
Installation, Operation & User Manual
–
Page 114
V 1.S.10 January 2021
V-1.S.1
After each printhead has its own unique IP Address you can connect the HMI and
printheads to the Junction Box and establish connection:
-
Turn on the power to the junction box and the HMI and Printheads will begin
booting up, after the boot up is complete
–
Press the Settings button in the top
right-hand corner then press the General Settings button on the bottom left-hand side
of the screen
. Then press the center tab which is labelled “Advanced Settings”.
-
Press the first option under Network Settings which is “HMI Network Settings”
and
change the HMI IP address to the 192.168.1.203 and set the gateway to
192.168.1.1 When finished the HMI Network settings should look like the
picture below. press OK.
10.
Press “Printer network settings”
.
11.
Press the button “Discover TIJ Devices” on the bottom left
-hand side of the screen. The
printers connected to the Junction Box with the appropriate IP range (the same range as
the HMI) will appear.
NOTE:
if a printer does not appear, tap on
“Add new device”
and manually add if the
IP is known.