Exit Reader Connections
Color
Wire
Connection
Red
Join to entry reader
red
wire ( 12VDC positive)
Black
Join to entry reader
black
wire ( 12VDC negative)
Green
Join to entry reader
green
wire (Wiegand Data 0)
White
D1/NB
Wiegand Data 1 (
alternate reader port to entry reader
)
Brown
Join to entry reader
brown
wire (LED control)
Blue
Join to entry reader
blue
wire (beeper control)
Shield
Join the shield (drain) wires together. Frame grounded at one point only
Connecting 4 Wiegand Readers
Multiple reader mode allows the connection of 4 Wiegand readers controlling 2 doors, each with entry/exit
readers. To connect 4 Wiegand reading devices to a Protege module:
⦁
Door 1 entry reader is connected to reader
port 1
⦁
Door 1 exit reader has its Wiegand Data 1 wire connected to the reader
port 2
D1 connection
⦁
Door 2 entry reader is connected to reader
port 2
⦁
Door 2 exit reader has its Wiegand Data 1 wire connected to the reader
port 1
D1 connection
⦁
The
Multiple reader input port 1
option is enabled in the reader expander programming (General | Options)
⦁
The
Multiple reader input port 2
option is enabled in the reader expander programming (General | Options)
To connect two Wiegand readers to a reader port the
Multiple reader input port 1/2
option must be enabled in
the reader expander programming. When this option is disabled the reader port will only process a single reader.
Enabling Wiegand Mode
TSL readers are shipped in RS-485 configuration by default. To change a reader to Wiegand mode it must be
enabled using a mobile device running the Protege Config App. The Config App's
Reader Configuration
will need
a config with the
Output Mode
set to
Wiegand Output
.
For programming instructions, see the
ICT Card Reader Configuration Guide
, available from the ICT website.
TSL Multi-Technology Card Reader | Installation Manual
29