Wiegand Reader Connection (Entry / Exit)
In multiple reader mode, the secondary card reader has all connections wired to the same reader port as the
primary reader, except the Data 1 connection which is wired to the Data 1 input on the alternate reader port.
The normal primary reader connection operates as the
entry
reader, and the secondary reader that is multiplexed
into the alternate reader port will operate as the
exit
reader.
1
2
3
4
5
6
7
8
9
0
X
L1
L2
BZ
C
D0/
D1/
NA
NB
V+
V-
L1
L2
BZ
C
D0/
D1/
NA
NB
V+
V-
Entry Reader Connections
Color
Wire
Connection
Red
V+
12VDC positive
Black
V-
12VDC negative
Green
D0/NA
Wiegand Data 0
White
D1/NB
Wiegand Data 1
Brown
L1
LED control
Blue
BZ
beeper control
Shield
Join the shield (drain) wires together. Frame grounded at one point only
TSL Multi-Technology Card Reader | Installation Manual
28