OSDP Baud Rate Requirement
For a card reader operating in OSDP mode to communicate with an OSDP server, the reader must have the same
baud rate setting as the reader port it is connected to. The default reader baud rate is 38400.
ICT card readers support the following baud rates:
Supported Baud Rates
4800 baud
9600 baud
19200 baud
38400 baud (default)
57600 baud
115200 baud
The card reader baud rate can be programmed using a mobile device running the Protege Config App.
The Config App
Reader Configuration
will need a config with the
Uart Configuration
TLV selected, with the
Baud
set to match the connected reader port.
For detailed information on programming ICT card readers, see the
ICT Card Reader Configuration Guide
, available
from the ICT website.
OSDP Reader Addressing
For a card reader operating in OSDP mode to be recognized on a third-party system, the reader address may need
to be configured to meet the third-party system's addressing requirements.
The address of TSL card readers can be programmed using a mobile device running the Protege Config App. The
Config App
Reader Configuration
will need a config with the
Reader Address
TLV selected, with the address set
as required for the third-party system.
TSL Multi-Technology Card Reader | Installation Manual