Deck Open Problem
»
Code: E19
LED Light Display: 5 red +1 red
LCM Display: As shown in figure below
Cause:
1. The deck is open for over 30 seconds.
2. The reject bar has problem.
Corrective Measure:
1. Close the deck and reactive the power.
2. Retry once a minute for 10 times, if the problem is not
resolved then remove the LCM panel to leave this
exception and notify ICT personnel for support.
«
Motor Error
:
A&B
»
Code: E20
LED Light Display: 7 red
LCM Display: As shown in figure below
Cause: Both the first and second group motors cannot be positioned.
Corrective Measure: Please see reference instructions for “E21” and “E22” below.
Flight Deck
Error E19
Coin Jam
E20
Содержание cc6000
Страница 1: ...1...
Страница 7: ...7 1 3 Dimensions Unit mm Mounting position Vertical max deviation 3 Mark of conformity CE FCC...
Страница 9: ...9 Coin Tubes Press the latch as shown below to remove the coin cassette...
Страница 49: ...49 4 3 Wire Harness Pin Assignment for JPSTD interface Main wire harness...
Страница 50: ...50...
Страница 51: ...51 JPSTD wire harness for ICT Bill Acceptor...
Страница 52: ...52...
Страница 53: ...53 4 4 Wire Harness Pin Assignment for MDB interface Main wire harness...
Страница 54: ...54...
Страница 55: ...55 MDB wire harness for ICT Bill Acceptor...
Страница 56: ...56...
Страница 59: ...59 4 6 Wire Harness Pin Assignment for Download Box...
Страница 60: ...60 5 I O Circuit JPSTD Interface...
Страница 61: ...61 MDB Interface...
Страница 62: ...62 Executive Interface...
Страница 64: ...64...
Страница 97: ...97 www ictgroup com tw 2017 International Currency Technologies Corporation V 1 9 Part Number Beta 2017 08 24...