18
8.4)
Ductwork and Filter:
Installation:
Design and install air distribution system to comply with
Air Conditioning Contractors of America manuals or
other approved methods that conform to local codes
and good trade practices.
When furnace supply ducts carry air outside furnace
area, seal return air duct to furnace casing and
terminate duct outside furnace space.
Install air conditioning cooling coil (evaporator) on
downstream side (in the supply air plenum) or furnace.
If separate evaporator and blower unit is used, install
good sealing dampers for air flow control. Cold air from
the evaporator coil going through the furnace could
cause condensation and shorten furnace life.
CAUTION
Dampers (purchased locally) MUST be
automatic.
WARNING
WARNING
Poison carbon monoxide gas hazard.
Do NOT draw return air from inside a
closet or utility room. Return air duct
MUST be sealed to furnace casing.
Failure to properly seal duct can result in
death, personal injury and/or property
damage.
WARNING
WARNING
Poison carbon monoxide gas hazard.
Install evaporator coil on the supply side of
the furnace ducting.
Evaporator coil installed in return side
ducting can cause condensation to form
inside heat exchanger resulting in heat
exchanger failure. This could result in
death, personal injury and/or property
damage.
!
!
Содержание OLR Series
Страница 29: ...DNS 0571 Rev B DNS 0573 Rev B 30 FIGURE 5 1 Model OLR105A12B FIGURE 5 2 Model OLR160B20B...
Страница 30: ...31 FIGURE 5 3 Model OUF105A12B FIGURE 5 4 Model OUF160B18 DNS 0568 Rev C DNS 0572 Rev C...
Страница 31: ...FIGURE 5 5 Model OLF105A12B DNS 0570 Rev B FIGURE 5 6 Model NOUF105A12B 32 DNS 0674 Rev C...
Страница 32: ...33 FIGURE 5 7 Model NOUF160B18B FIGURE 5 8 Model NOLF105A12B DNS 0676 Rev C DNS 0675 Rev D...