The configuration is divided to three areas with different color. They are UART, Communication,
and CAN configuration area.
UART Configuration:
*
Baud rate:
Set the UART baud rate. Different CAN converters have different max. UART
baud rates. Users can select the proper UART baud for the CAN converters.
*
Data bit:
Set the UART data bit. The CAN converters support 4 kinds of data bit
configuration.
*
Stop bit:
Set the UART stop bit. The CAN converters support 2 kinds of stop bit
configuration.
*
Parity bit:
Set the UART parity bit. The CAN converters support 3 kinds of parity bit
configuration.
*
Add Checksum:
Set the CAN converters to enable or disable the checksum mechanism
in the UART communication. If enable the checksum function, all UART strings from / to
the tM-7530 must append two bytes of the checksum information. For checksum
algorithm,
please refer to the Node in the
page 38
.
*
Error Response:
Set the CAN converters to enable or disable the error response