ICP DAS PMC/PMD Series User Manual
309
The SNMP Variables naming rule of the Power Meter connected with PMC-5151.
Every power meter that is connected to PMC-5151 provides the SNMP Variables as above (with
its specific prefix denoted).
The SNMP Variables naming rule of the power meters on Com2
The Power Meter1 SNMP Variables are shown as above (with prefix
com2
pm
1
), the Power
Meter2 SNMP Variables are similar to listed information above but with prefix
com2
pm
2
instead
,
and the Power Meter16 SNMP Variables are also similar to the listed information above
but with prefix
com2
pm
16
instead
.
The SNMP Variables naming rule of the power meters
on Com3
The Power Meter1 SNMP Variables are similar as listed information above but with prefix
com3
pm
1
,
the Power Meter2 SNMP Variables are similar to listed information above but with
prefix
com3
pm
2
instead
,
and the Power Meter16 SNMP Variables are also similar to the listed
information above but with prefix
com3
pm
16
instead
.
The SNMP Variables naming rule of the power meters on LAN
The Power Meter1 SNMP Variables are similar as listed information above but with prefix
lan
pm
1
, t
he Power Meter2 SNMP Variables are similar to listed information above but with
prefix
lan
pm
2
instead
,
and the Power Meter16 SNMP Variables are also similar to the listed
information above but with prefix
lan
pm
16
instead
.
xwBoard
xwBoardName
xwBoardDIAmount
xwBoardDOAmount
xwBoardAIAmount
xwBoardAOAmount
xwBoardDIIndex
xwBoardDIName
xwBoardDIValue
xwBoardDICounterType
xwBoardDICounterInitValue
xwBoardDICounterValue
xwBoardDOIndex
xwBoardDOName
xwBoardDOValue
xwBoardDOPowerOnValue
xwBoardDOAdvFunction
xwBoardAIIndex
xwBoardAIName
xwBoardAIValue
xwBoardAIType
xwBoardAIDeadband
xwBoardAIScaleMin
xwBoardAIScaleMax
xwBoardAOIndex
xwBoardAOName
xwBoardAOValue
xwBoardAOType
xwBoardAOPowerOnValue
I/O Module1(On Com2)
com2io1Index
com2io1Interface
com2io1ModbusID
com2io1ModuleName
com2io1ConnectionStatus
com2io1DiscInputAmount
com2io1CoilOutputAmount
com2io1InputRegAmount
com2io1HoldingRegAmount
com2io1DiscInputIndex
Содержание PMC series
Страница 1: ...ICP DAS PMC PMD Power Meter Concentrator Series User Manual Version 3 1 8...
Страница 51: ...ICP DAS PMC PMD Series User Manual 38 Figure5 32 Energy Usage Breakdown by Circuit Group Chart...
Страница 72: ...ICP DAS PMC PMD Series User Manual 59 Figure6 11 Security setting interface of VPN function...
Страница 165: ...ICP DAS PMC PMD Series User Manual 152 The Import of MQTT Topic...
Страница 315: ...ICP DAS PMC PMD Series User Manual 302 B Start the DCON Utility and verify if the COM Port parameters are accurate...