High-speed Multifunction Boards
User Manual, Ver. 1.0, May 2015, PMH-029-10 Page 53
6.3.4
Analog Output Registers
Register 6.3.4-1 Base+0x20
AO Control/Status
Bit
Description
Read
Write
0:23
AO Command.
Writing a AO command.
Yes
Yes
24
AO Command Read.
Reading a 1 indicates a Command Status is
ready. Reading a 0 indicates a Command Status is busy.
Yes
No
25:31
Reserved.
Yes
No
For more detailed information, refer to the documentation for the AD5752, which can be found at:
http://www.analog.com/media/en/technical-documentation/data-sheets/AD5722_5732_5752.pdf