3.8 Advance Motion
1 2-axes continuous interpolation of rectangle: Perform2-axes continuous
interpolation of rectangle.
i8094MF_RECTANGLE()
( Please refer to section 6.4.1 of I8094/I8094F user
manual)
2 2-axes continuous interpolation of line:
Initial setting continuous interpolation of 2-axes line( Symmetrical T-profile).
i8094MF_LINE_2D_INITIAL()
( Please refer to section 6.4.2 of I8094/I8094F user
manual)
Perform 2-axes continuous interpolation of line.
i8094MF_LINE_2D_CONTINUE()
( Please refer to section 6.4.2 of I8094/I8094F
user manual)
3 3-axes continuous interpolation of line:
Initial setting continuous interpolation of line( symmetrical T-profile).
i8094MF_LINE_3D_INITIAL()
( Please refer to section 6.4.3 of I8094/I8094F user
manual)
Perform 3-axes continuous interpolation of line.
i8094MF_LINE_3D_CONTINUE()
( Please refer to section 6.4.3 of I8094/I8094F
user manual)
4 Others continuous interpolation: Muti-point continuous interpolation, 3-axes Helix
interpolation, 2-axes Ratio motion ( Please refer to section 6.4.4~6.4.7 of I8094/I8094F
user manual)
3.9 Synchronization Action
i8094 also offer many function of Synchronization Action, as compare EP, LATCH….and
so on( Please refer to section 6.3 of I8094/I8094F user manaul)
http:/www.icpdas.com I8094Getting Started ManualVer.2.3 2008/4/28
40