2.2.3 Jumper and Switch Settings
JP7
Jumper 7 controls the EMG-A signal of the CON6 connector. The following diagram is shown the
selection condition of the jumper 7.
Fig. 2.6 Jumper 7 setting
JP8/9, JP10/11, JP12/13, JP14/15
The Jumper8~15 are used to set the signal type of the pulse output signals. The output signal
type could be differential line driver output or open collector output. The JP8 ~JP9 are set XPP
、
XPM for X-axis(CON1), JP10 ~JP11 are for Y-axis, JP12 ~JP13 are for Z-axis and JP14 ~JP15
are for U-axis. The 2-3 Pin short is the differential line driver mode. The 1-2 Pin short is the Open
Collector mode, as below example
http:/www.icpdas.com I8094Getting Started ManualVer.2.3 2008/4/28
22