4.2 Write data to FRnet DO
void
i8092MF_FRNET_OUT(
BYTE
cardNo,
WORD
wSA,
WORD
data
)
Description:
This function write data to the FRnet digital output.
SA
means the
S
ending
A
ddress
which can be one of the legal group number of FRnet. One group
comprises 16 bits data. Therefore, total 128 DO can be defined for one FRnet
interface.
Parameters:
cardNo
:
Module number
wSA
:
Group number, range 0~7
Note: 8~15 are used by digital inputs
data
: 16-bit
data
Return:
None
Example:
i8092MF_
FRNET_OUT(1, 0,0xffff);