http://www.icpdas.com
應用程式函式庫
v2.0
190
D12
EXPLS
When it is 1, the external (MPLS) controlled single step
interpolation mode is engaged.
D13
CMPLS
When it is 1, the command controlled single step interpolation
mode is engaged.
D14
CIINT
Interrupt enable / disable setting during interpolation 0: disable
1: enable
D15
BPINT
Interrupt enable / disable setting during bit-pattern interpolation
0: disable 1: enable
B.7 Data Register: WR6/WR7
Data registers are used for setting the written command data. The low-word
data-writing 16-bit (WD15~WD0) is for register RR6 setting, and the
high-word data-writing 16-bit (WD31~WD16) is for register RR7 setting.
WR6
WR7
The user can write command data with a designated data length into the
write register. It does not matter to write WR6 or WR7 first (when 8-bit data
bus is used, the registers are WR6L, WR6H, WR7L and WR7H).
The written data is binary formatted; 2’ complement is for negatives.
For command data, the user should use designated data length. For
instance, the circular interpolation of the finish point should be set by a
signed 32-bit format with the data length of 4 bytes, although its
calculatable data range is from –8,388,608 to +8,388,607 signed 24-bit
format.
The contents of WR6 and WR7 are unknown while resetting.
B.8 Main Status Register: RR0
This register is used for displaying the driving and error status of each axis.
It also displays interpolation driving, ready signal for continuous
interpolation, quadrant of circular interpolation and stack counter of bit
pattern interpolation.