1.2.2 Pair Connection mode
As the name suggests, this mode is designed to use two CAN converters for pair
connection. The main purpose will transfer the interface from UART to CAN, and then
transfer again the interface from CAN to UART, so that the interface conversion effect
can be achieved without modifying the program of the field device as below figure .
In addition, if only one CAN converter (for example: I -7530) uses this mode, the
effect will be similar to the function of transparent transmission. The data be inputed
from the UART side of the CAN converter will be directly output t o the CAN message as
below figure.