55
Control word: 6040h (under csp mode)
Bit
15 ~ 10
9
8
7
6 ~ 4
3
2
1
0
r
r
h
fr
r
eo
qs
ev
so
r = reserve
fr = fault reset
h = halt
eo = Enable operation
qs = quick stop
ev = enable voltage
so = switch on
Status word: 6041h (under csp mode)
Bit 15~13 12
11 10 9 8 7
6
5
4
3
2
1
0
r
driver follows
command value
ila
r
rm r
w
sod qs
ve
f
oe
so
rtso
r = reserve
fe = following error
ila = internal limit active
rm = remote
w = warning
sod = switch on disabled
qs = quick stop
ve = voltage enabled
f = fault
oe = operation enabled
so = switched on
rtso = ready to switch on
bit Name
Value Definition
12
driver follows command
value
0
Operation is not performed according to the
target position
1
Operation is performed according to the target
position