36
0: interpolation mode
1: high speed mode(It is suitable for high-speed and short-distance
commands, and the command execution time should be less than 500ms)
0x5000 --
Store
parameters
00h Number of
entries
U8
rw
N
N
3
01h Save all
Parameters
0 -
4294967295
U32 rw
N
N
00000000h
02h Load Factory
0 - 1
U32 rw
Y
N
00000001h
03h Save counter
0 -
4294967295
U32 ro
Y
N
00000000h
To enable EEPROM, please set Load Factory to 0,
And set Save all Parameters from 0 to 1 to save the parameters,
If the archive fails, the EEPROM Error(0x5001:01) is 1,
Please reset Save all Parameters from 0 to 1,
If the save is successful, Save c 1
To restore to the default value, please set Load Factory to 1,
And set Save all Parameters from 0 to 1 to restore to the default value,
If the archive fails, the EEPROM Error is 1
If the save is successful, Save c 1
All parameters will be restored to preset values after power on again
0x5001 --
Store Status
00h Number of
entries
U8
rw
N
N
2
01h EEPROM Error
0 - 1
U32 ro
N
N
00000000h
02h Load EEPROM
0 - 1
U32 rw
Y
N
00000000h
If the EEPROM Error is 1 after power-on, it means that the EEPROM reading failed.
Please set Load EEPROM from 0 to 1, if successful, EEPROM Error is 0.
If the EEPROM Error is still 1, it means that a problem occurred during the last
archive, but it was not processed.
Please re-archive
Содержание ECAT-2094P
Страница 1: ...ECAT 2094P EtherCAT 4 Axis Pulse Output Module User Manual Version 1 0...
Страница 10: ...10 2 2 Alias Rotary Swtich The Alias range is 0x00 0xFF...
Страница 15: ...15 2 5 Stepper Motor Wiring...
Страница 17: ...17 Figure 2 Open collector wiring diagram...
Страница 24: ...24 is the total execution time of all slave application related operations...
Страница 71: ...71 Method35 37 The home detection position is the current position...