20
data (e.g. digital input, encoder value, etc.)
Outputs in Safe-Op state
The sync manager watchdog expires when the master application does not provide
new output process data within the configured watchdog time. In this case the slave
will automatically go from operational state to ERROR-SAFEOP state and set all the
outputs in a safe state. Will stop the stepper motor and the motor current will be
adjusted to 0.
Operational (Op)
Here both the process data object (PDO) and service data object (SDP) are fully
enabled. Master sends cyclic output data and read input data. This module supports
two types of Op modes: Free Run mode and Distributed Clock (DC) mode.
3.3
Synchronization Modes
ECAT-2094P devices support two different modes
Free Run: The master cycle time and slave cycle time is independent and not
synchronized.
Distributed Clock (DC): The master cycle time and slave cycle time are synchronized.
3.3.1
Free Run Mode
The slave operates autonomously according to its cycle and is not synchronized with
the EtherCAT cycle.
The master cycle time and the slave cycle time are fully independent
which means each slave device reads/writes its own process data according to its local time,
independent of the master’s cycle time.
Figure 4: Master-slave cycle in Free Run mode
Содержание ECAT-2094P
Страница 1: ...ECAT 2094P EtherCAT 4 Axis Pulse Output Module User Manual Version 1 0...
Страница 10: ...10 2 2 Alias Rotary Swtich The Alias range is 0x00 0xFF...
Страница 15: ...15 2 5 Stepper Motor Wiring...
Страница 17: ...17 Figure 2 Open collector wiring diagram...
Страница 24: ...24 is the total execution time of all slave application related operations...
Страница 71: ...71 Method35 37 The home detection position is the current position...