iCool COMPACT Cool Скачать руководство пользователя страница 7

Page

 

7

USER MANUAL FOR iCOOL RECOVERY SYSTEMS

 

MODEL C COMPACT MODELS 2009-2010 Updated Oct 2010.

Updates are published regularly on our website www.icoolsport.com

 

The 

MAiN OPERATiNG SCREEN

 provides many options which are covered elsewhere in this manual, however 

to quickly start the system you can simply accept the default water temperature setting of 15ºC or touch the  

ChANGE SETTiNGS

 button to select a different temperature. 10ºC will be inserted automatically but you can 

change to any temperature you require. 

The temperatures can 

also be displayed in Fahrenheit. This is explained later in this 

Manual.

Simply touch the up and down arrow buttons and the desired 

pool water temperature will appear on the bottom left-hand of 

the screen in the blue window marked  “SELECTED TEMPERA-

TURE”.  The right-hand side of the screen shows the outside air 

temperature. 

Once the pool water temperature you want your iCool to cool to 

is showing, touch the 

START

 button. This takes you back to the 

main run screen which is the screen that you will use most of the 

time during normal operation. 

STEP 5

Touch the 

START

 

PUMP

 button. This will start the pump operat-

ing and water should begin circulating. 

NOTE! When you touch 

START buttons they change to STOP buttons and can then be 

used to STOP that function if required.

iT iS ESSENTiAL ThAT ThE WATER iS FLOWiNG CORRECTLY 

BEFORE YOU TOUCh ThE 

START SYSTEM 

BUTTON.

 

The water flow is pre set to an optimum flow of about 15-20 litres 

or around 3-5 gallons per minute. This allows time for the heat 

exchanger to operate at maximum cooling efficiency. 

Pool water is completely changed approximately every 15 to 20 

minutes.

Do not touch the 

START SYSTEM

 button until you are sure that 

water is flowing smoothly. if water does not flow smoothly within a minute, please check that the hose from the 

bottom of the pool is flat on the floor and no part of it is higher than the top of the water. Check that the water 

in the pool is higher than the inlet connectors on the iCool. if this does not correct the problem the system will 

sound an alarm and a red warning screen will appear with information about how to correct the water flow prob-

lem. 

STEP 6

Now that you have pre set your desired temperature and started the circulating pump, the touch screen should 

look like the picture at the top of this page. (of course the temperatures may be different). Notice that the pump 

button will have changed from 

START

 to 

STOP

. You can use this same button to start and stop the pump at any 

time.

Now, touch the 

START SYSTEM

 button and the cooling cycle will begin. The water will be cooled to your preset 

temperature and the system will then cycle to maintain it at that temperature automatically. 

The SYSTEM can 

only be started once within any 3 minute period to avoid overloading the compressor. if you don’t hear it start do 

not touch the START SYSTEM again , it will start automatically after the 3 minutes safety period elapses.

if your iCool is the 

CONTRAST MODEL

 then, depending on the temperature you set, it will either heat or cool the 

water automatically to reach your preset temperature and then maintain it at that temperature.  More detailed 

information about the operation of the 

CONTRAST

 version can be found later in this manual.

FOR ThE SAFETY OF USERS, YOU CAN NOT SET TEMPERATURES BELOW 5°C OR ABOVE 45°C

. (

40°F-112°F)

iN AN EMERGENCY YOU CAN STOP ALL FUNCTiONS iMMEDiATELY BY TOUChiNG ThE “ALL STOP” BUTTON  

however, if the cabinet is hot, the fan may continue to run until the cabinet has cooled.

 WATER  TEMPERATURE SETTiNG SCREEN

START

START

START

START

START

START

10

22

22

30

15

24

 

MAiN OPERATiNG SCREEN

Содержание COMPACT Cool

Страница 1: ...DUAL TEMP TWIN Never use Chlorine Bromide or Salt in models with Stainless Steel Heat Exchangers Only the Titanium Heat Exchanger models can use Chlorine and Salt in the water Never use Bromide with...

Страница 2: ...e of the user receiving an electrical shock if any such potentially dangerous things should occur in most cases your iCool will shut itself down and a red warning screen will appear to assist you to i...

Страница 3: ...revent water from flowing Water pumps can not operate for long periods without water as the water provides the lubrication To prevent damage your iCool system will shut down the pump if water is not f...

Страница 4: ...ng unit or for permanent use a full iCool self powered filtration and sterilising unit The water level in the pool must be above the water inlet and outlet connections on the iCool The iCool must be o...

Страница 5: ...water This over ride function is only to be used for short periods where it is essential to keep your system operating until the reason for the false alarm can be determined and corrected WATER FLOW C...

Страница 6: ...STATUS BAR LiGhT TOUCh ThE LOGO SCREEN ANYWhERE TO CONTiNUE ThE STATUS BAR WiLL FLASh WhiTE The STATUS BAR on top of the iCool changes colour or flashes to give a clear indication of each function Whi...

Страница 7: ...water is flowing smoothly if water does not flow smoothly within a minute please check that the hose from the bottom of the pool is flat on the floor and no part of it is higher than the top of the wa...

Страница 8: ...warning screen will appear This could happen in extremely hot conditions or if the unit is covered by an object such as a towel or anything that prevents proper airflow The OUTSiDE TEMPERATURE WiNDOW...

Страница 9: ...UM SETTiNGS ARE AUTOMATiCALLY SELECTED so there usually no need to use this feature The three settings you can change are the fan speed range the temperature from degrees Centigrade to Fahrenheit and...

Страница 10: ...ete using the pool your system will not allow you to set temperatures below 5 C 40 F if the model you are using is the contrast model which also provides heating for contrast therapy you cannot set th...

Страница 11: ...which of course your iCool does perfectly The session timer is set up from the main TiME SETTiNG SCREEN by touching the SET COUNTDOWN button The numbers on the setting screen in the bottom right hand...

Страница 12: ...tes to plug in their iPods or MP3 players or any other entertain ment devices and listen to powerful quality sound while they use the iCool recovery system This has been a very popular feature and con...

Страница 13: ...the main run screen for more than 10 seconds you can only lock from this main screen A picture of a lock will appear While ever this lock is visible it is not possible to make any inputs or to change...

Страница 14: ...e best electronic systems occasionally have problems especially in portable systems that have a relatively hard life Fortunately we have very few such problems but as an added benefit we have built in...

Страница 15: ...10 Watts Yes 10 Watts Yes 20 Watts hi RESOLUTiON COLOUR TOUCh SCREEN Yes 800 x 480 Yes 800 x 480 Yes 800 x 480 ELECTRiCALLY iSOLATED PUMP S STEEL ShiELDED Yes 25 Litres per minute pre set Yes 25 Litre...

Страница 16: ...Page 16 USER MANUAL FOR iCOOL RECOVERY SYSTEMS MODEL C COMPACT MODELS 2009 2010 Updated Oct 2010 Updates are published regularly on our website www icoolsport com www iCoolSport com...

Отзывы: