USER MANUAL FOR iCOOL RECOVERY SYSTEMS

 

MODEL C COMPACT MODELS 2009-2010 Updated Oct 2010.

Updates are published regularly on our website www.icoolsport.com

 

POOL SETUP ADViCE

Before  you turn on your iCool system you must set up and fill the pool.  iCool portable inflatable pools and semi 

permanent demountable pools come with their own instructions and are easy to set up. Just be sure that they 

are in the position you require before you fill them with water as the weight of the water will make it impossible to 

move them once they are filled.

  ADViCE ABOUT OBTAiNiNG ThE CORRECT FLOW OF WATER

OCCASiONALLY YOU MAY EXPERiENCE SOME DiFFiCULTY GETTiNG ThE WATER TO FLOW 

CORRECTLY ThROUGh YOUR iCOOL DUE TO TRAPPED AiR iN ThE SYSTEM OR ThE hOSES. 

PLEASE READ AND FOLLOW ThESE SiMPLE iNSTRUCTiONS TO LEARN hOW TO CORRECT ThiS.

ABOUT PUMPS. Water flow through your iCool is produced by a high-quality long life circulating type pump 

that for safety is completely isolated electrically from the water. 

Circulating type pumps can lift and move water reliably for many thousands of hours, however they do not pro-

vide suction and are therefore not self priming. Self priming type pumps are generally not as reliable over long 

periods and so are not suitable for this type of system. 

This means that the pump in your iCool can not begin to operate unless it is fed with a head of water above the 

pump and any air tapped in the system is removed. The water in the pool must be above the water inlet con-

nector on your iCool cooling system before you start to pump. Furthermore, there must be no air trapped in the 

supply hose and no part of the hose from the pool to the cooling system can be above the level of the water as 

this traps air which can prevent water from flowing.  

Water pumps can not operate for long periods without water as the water provides the lubrication. To prevent 

damage, your iCool system will shut down the pump if water is not flowing properly for more than ONE minute.  

if this happens a warning screen will normally appear to explain to you how to correct the problem. 

There are several easy ways to clear trapped air in the system. For example, by touching the PUMP ON OFF 

button 3 or 4 times so the pump is off for about 5 to 10 seconds each time. The surge when the pump starts can 

often clear the trapped air but it may take a few times if there is a lot of trapped air.

if you still do not have a good flow of water try detaching the water inlet hose at the iCool until you see a

 

good 

clear flow of water coming out of the hose and quickly snap it back into position and lock it again.

You can do the same thing with the outlet hose at the iCool unit, this also allows the air to escape.

YOU ONLY NEED TO BLEED ThE SYSTEM ONCE FOR EACh SET UP. Once primed of air, the system will re-

main primed until it is emptied or moved and water will normally flow instantly each time you start the pump.

NEVER USE CORROSiVE ChEMiCALS iN STAiNLESS STEEL MODELS

Bromide and Chlorine can cause major long term damage even to the high grade stainless steel heat 

exchanger in your iCool and cause a total system failure that is not covered by your warranty. These chemicals 

eat away most metals and are are also damaging to athletes. For total control of bacteria use an innexpensive 

iCool Ultra Violet Steraliser unit. This is the totally safe way to deal with bacteria and keep your pool safe 

without using expensive and potentially damaging chemicals. it is also much safer for athletes. Also please 

avoid the use of salt water to ensure long life of your system. 

iF YOU hAVE ThE TiTANiUM hEAT EXChANGER MODEL YOU MAY USE LOW CONCENTRATiONS OF 

ChLORiNE AND SALT WATER BUT NEW USE BROMiDE.

Содержание COMPACT Cool

Страница 1: ...DUAL TEMP TWIN Never use Chlorine Bromide or Salt in models with Stainless Steel Heat Exchangers Only the Titanium Heat Exchanger models can use Chlorine and Salt in the water Never use Bromide with...

Страница 2: ...e of the user receiving an electrical shock if any such potentially dangerous things should occur in most cases your iCool will shut itself down and a red warning screen will appear to assist you to i...

Страница 3: ...revent water from flowing Water pumps can not operate for long periods without water as the water provides the lubrication To prevent damage your iCool system will shut down the pump if water is not f...

Страница 4: ...ng unit or for permanent use a full iCool self powered filtration and sterilising unit The water level in the pool must be above the water inlet and outlet connections on the iCool The iCool must be o...

Страница 5: ...water This over ride function is only to be used for short periods where it is essential to keep your system operating until the reason for the false alarm can be determined and corrected WATER FLOW C...

Страница 6: ...STATUS BAR LiGhT TOUCh ThE LOGO SCREEN ANYWhERE TO CONTiNUE ThE STATUS BAR WiLL FLASh WhiTE The STATUS BAR on top of the iCool changes colour or flashes to give a clear indication of each function Whi...

Страница 7: ...water is flowing smoothly if water does not flow smoothly within a minute please check that the hose from the bottom of the pool is flat on the floor and no part of it is higher than the top of the wa...

Страница 8: ...warning screen will appear This could happen in extremely hot conditions or if the unit is covered by an object such as a towel or anything that prevents proper airflow The OUTSiDE TEMPERATURE WiNDOW...

Страница 9: ...UM SETTiNGS ARE AUTOMATiCALLY SELECTED so there usually no need to use this feature The three settings you can change are the fan speed range the temperature from degrees Centigrade to Fahrenheit and...

Страница 10: ...ete using the pool your system will not allow you to set temperatures below 5 C 40 F if the model you are using is the contrast model which also provides heating for contrast therapy you cannot set th...

Страница 11: ...which of course your iCool does perfectly The session timer is set up from the main TiME SETTiNG SCREEN by touching the SET COUNTDOWN button The numbers on the setting screen in the bottom right hand...

Страница 12: ...tes to plug in their iPods or MP3 players or any other entertain ment devices and listen to powerful quality sound while they use the iCool recovery system This has been a very popular feature and con...

Страница 13: ...the main run screen for more than 10 seconds you can only lock from this main screen A picture of a lock will appear While ever this lock is visible it is not possible to make any inputs or to change...

Страница 14: ...e best electronic systems occasionally have problems especially in portable systems that have a relatively hard life Fortunately we have very few such problems but as an added benefit we have built in...

Страница 15: ...10 Watts Yes 10 Watts Yes 20 Watts hi RESOLUTiON COLOUR TOUCh SCREEN Yes 800 x 480 Yes 800 x 480 Yes 800 x 480 ELECTRiCALLY iSOLATED PUMP S STEEL ShiELDED Yes 25 Litres per minute pre set Yes 25 Litre...

Страница 16: ...Page 16 USER MANUAL FOR iCOOL RECOVERY SYSTEMS MODEL C COMPACT MODELS 2009 2010 Updated Oct 2010 Updates are published regularly on our website www icoolsport com www iCoolSport com...

Отзывы: