USER MANUAL FOR iCOOL RECOVERY SYSTEMS

 

MODEL C COMPACT MODELS 2009-2010 Updated Oct 2010.

Updates are published regularly on our website www.icoolsport.com

  

ThERE ARE ThREE VERSiONS OF ThE iCOOL COMPACTS 

C

OMPACT Cool 

is our most popular and economic system. it provides 

rapid cooling, fully automatic control and excellent mobility.

C

OMPACT Dual Temp

 provides all the power and function of the “Cool” 

plus both cooling and heating automatically, for advanced contrast 

therapy sessions. 

C

OMPACT Twin

 is the most powerful mobile ice bath cooling system 

available. it has all the features of the “Cool” plus extra cooling power 

and stronger water flow for cooling 2 pools at once if required or for cooling 

spa baths and larger iCool Demountable multi person pools.

MODEL

COOLiNG POWER

hEATiNG POWER

VOLTAGES

AVAiLABLE

COMPACT Cool

3000 Watts

-

220-240 0R 110

COMPACT Dual Temp

3200 Watts

2400 Watts

220-240 OR 110

COMPACT Twin

5100 watts

-

220-240 OR 110

iMPORTANT SAFETY ADViCE

POWER SUPPLY VOLTAGE

iCools can only be used with the voltage marked on the machine, they are not multi voltage. The voltage is 

marked next to the main power socket.

TO ENSURE SAFE OPERATiON ThE POWER OUTLET YOU USE MUST hAVE A PROPER EARTh CONNECTiON.

BUiLT iN SAFETY SYSTEMS

Your iCool system has many safety features to protect against such things as a loss of water flow, overheating 

of the system, or any chance of the user receiving an electrical shock. if any such potentially dangerous things 

should occur, in most cases your iCool will shut itself down and a red warning screen will appear to assist you 

to identify and correct the problem. in the case of overheating, the main fan will continue to run for some time 

until the temperature is safely back to normal.  

For the safety of users, any leakage of even a small amount of electrical current will cause the system to 

instantly remove all electrical power.  

in the unlikely event that your system shuts itself down for any of these reasons, you must identify and correct 

the problem that has caused the safety systems to operate before allowing anyone to use the system. 

PLEASE TEST ThE EARTh LEAKAGE SAFETY DEViCE REGULARLY 

The main power switch is also part of the electrical safety circuit that can prevents the possibility of electric 

shock. it is essential to test this safety system each time you use the iCool to make 

certain it is operating correctly. This is very easy to do and takes only a few seconds.

Turn on the main switch and then press the orange test button just above the switch. 

if the safety system is working normally, pressing the test button will cause the main 

power switch to shut off instantly. 

After a successful test, reset the main switch to ON to begin normal operation. if 

pressing the test button fails to instantly shut off the power switch DO NOT USE ThE 

SYSTEM  until you contact iCool for advice. Failures of this system are very rare.

ThE OPERATiON OF ALL 3 MODELS iS ThE SAME EXCEPT WhERE NOTED 

iN ThiS MANUAL

Содержание COMPACT Cool

Страница 1: ...DUAL TEMP TWIN Never use Chlorine Bromide or Salt in models with Stainless Steel Heat Exchangers Only the Titanium Heat Exchanger models can use Chlorine and Salt in the water Never use Bromide with...

Страница 2: ...e of the user receiving an electrical shock if any such potentially dangerous things should occur in most cases your iCool will shut itself down and a red warning screen will appear to assist you to i...

Страница 3: ...revent water from flowing Water pumps can not operate for long periods without water as the water provides the lubrication To prevent damage your iCool system will shut down the pump if water is not f...

Страница 4: ...ng unit or for permanent use a full iCool self powered filtration and sterilising unit The water level in the pool must be above the water inlet and outlet connections on the iCool The iCool must be o...

Страница 5: ...water This over ride function is only to be used for short periods where it is essential to keep your system operating until the reason for the false alarm can be determined and corrected WATER FLOW C...

Страница 6: ...STATUS BAR LiGhT TOUCh ThE LOGO SCREEN ANYWhERE TO CONTiNUE ThE STATUS BAR WiLL FLASh WhiTE The STATUS BAR on top of the iCool changes colour or flashes to give a clear indication of each function Whi...

Страница 7: ...water is flowing smoothly if water does not flow smoothly within a minute please check that the hose from the bottom of the pool is flat on the floor and no part of it is higher than the top of the wa...

Страница 8: ...warning screen will appear This could happen in extremely hot conditions or if the unit is covered by an object such as a towel or anything that prevents proper airflow The OUTSiDE TEMPERATURE WiNDOW...

Страница 9: ...UM SETTiNGS ARE AUTOMATiCALLY SELECTED so there usually no need to use this feature The three settings you can change are the fan speed range the temperature from degrees Centigrade to Fahrenheit and...

Страница 10: ...ete using the pool your system will not allow you to set temperatures below 5 C 40 F if the model you are using is the contrast model which also provides heating for contrast therapy you cannot set th...

Страница 11: ...which of course your iCool does perfectly The session timer is set up from the main TiME SETTiNG SCREEN by touching the SET COUNTDOWN button The numbers on the setting screen in the bottom right hand...

Страница 12: ...tes to plug in their iPods or MP3 players or any other entertain ment devices and listen to powerful quality sound while they use the iCool recovery system This has been a very popular feature and con...

Страница 13: ...the main run screen for more than 10 seconds you can only lock from this main screen A picture of a lock will appear While ever this lock is visible it is not possible to make any inputs or to change...

Страница 14: ...e best electronic systems occasionally have problems especially in portable systems that have a relatively hard life Fortunately we have very few such problems but as an added benefit we have built in...

Страница 15: ...10 Watts Yes 10 Watts Yes 20 Watts hi RESOLUTiON COLOUR TOUCh SCREEN Yes 800 x 480 Yes 800 x 480 Yes 800 x 480 ELECTRiCALLY iSOLATED PUMP S STEEL ShiELDED Yes 25 Litres per minute pre set Yes 25 Litre...

Страница 16: ...Page 16 USER MANUAL FOR iCOOL RECOVERY SYSTEMS MODEL C COMPACT MODELS 2009 2010 Updated Oct 2010 Updates are published regularly on our website www icoolsport com www iCoolSport com...

Отзывы: