SUSPENSION MOUNTING (FLYING)
The end caps of the column array are attached to the main frame with four metric M6 machine screws. Removing these screws and replac-
LQJWKHPZLWKH\HEROWVSURYLGHVXSWRIRXUDWWDFKPHQWSRLQWVIRUÀ\LQJ:HUHFRPPHQGXVLQJDOOIRXU,IRQO\DUHXVHGWKHFROXPQZLOOQRW
hang straight. It will either tilt up or down.
SERVICING
GENERAL INFORMATION
<RXU,FRQ\[VWHHUDEOHFROXPQDUUD\FRQWDLQVQRXVHUVHUYLFHDEOHSDUWVDQGDOOVHUYLFHVKRXOGEHUHIHUUHGWRTXDOL¿HGVHUYLFHSHUVRQQHO
*UHDWFDUHZDVWDNHQLQLWVGHVLJQKRZHYHUWRDOORZLWWREHVHUYLFHGLQWKH¿HOGZLWKRXWEHLQJUHPRYHGIURPLWVPRXQWLQJSRVLWLRQ7KH
transducers can be replaced from the front of the column by removing the grille to expose the transducers and their mounting screws.
7KHFKDQQHOGLJLWDODPSOL¿HU'63DQGDVVRFLDWHGSRZHUVXSSO\WKDWDUHWKHKHDUWRIHDFKFKDQQHOPRGXOHDUHRQHVLQJOHDVVHPEO\
that can easily be taken out and replaced from the rear.
TROUBLE SHOOTING HINTS
HUM
The most common sources of system hum are the program source or an improper or poor ground on an audio signal line. Check the pro-
gram source to make sure the hum isn’t originating there. Carefully check all the audio connections to make sure they are properly made.
NOISE
Most noise problems are the result of improper grounding or of noise being induced into the audio signal line from adjacent noise sources,
VXFKDVÀXRUHVFHQWOLJKWVDQGFORVHSUR[LPLW\RIWKHDXGLRVLJQDOOLQHVWROLQHVUDGLDWLQJQRLVH&DUHIXOO\UHYLHZDOOWKHDXGLRFRQQHFWLRQV
and turn off all the lights and any other suspected noise sources to identify the source of the interference.
SUSPECTED TRANSDUCER FAILURE
Defective transducers are hard to locate in steerable column arrays because the transducers are so close together. If one is bad, it’s hard
WRWHOOZKLFKRQHLWLV7KHGLJLWDOVWHHULQJDOVRUHGXFHVWKHGULYHWRVRPHRIWKHWUDQVGXFHUVPDNLQJLWGLI¿FXOWWRGHWHUPLQHLIDFHUWDLQ
transducer has failed or is just being driven at a much lower level than other transducers. No movement of the cone of a transducer is not
positive proof that the transducer is bad. It could be that beam steering is limiting the drive to the transducer or restricting its use to a nar-
row frequency band.
Because of this, in IC Live arrays Preset 00 is set to send an equal signal to all transducers. To check for a defective transducer, select
3UHVHWUHPRYHWKHJULOOHIURPWKHPRGXOHVDQGXVH\RXU¿QJHUWLSVWRIHHOIRUFRQHYLEUDWLRQVZKLOHPXVLFLVEHLQJSOD\HGWKURXJKWKH
system.
For more detailed troubleshooting hints, please refer to pages 62 to 69.
47
Users Manual
ICL-FR