3
CONVERTER MODE APPLICATION
3-11
3. Using an external headset (continued)
1. Configuration
Access the VE-PG3 setting screen, and set the items as shown below.
VE-PG3 (Area A)
Menu Item
Setting Screen
Setting Item
Item Name
Value
Operating Mode Operating Mode
Operating Mode
Operating Mode
Converter
EXT I/O Port Mode
EXT I/O Port Mode
Combined (EXT I/O 2 (EXT2))
V/RoIP
IP Line
SIP Server
IP Phone Number
32 (Extension Number set in the VE-PG3 in area B)
SIP Server Address
192.168.0.3 (IP address set in the VE-PG3 in area B)
SIP Service Domain
192.168.0.3 (Extension Domain set in the VE-PG3 in area B)
User ID
32 (Extension Number set in the VE-PG3 in area B)
Password
(Password set in the VE-PG3 in area B)
List of SIP Server Entries Connection Status
Connection successful
Extension
Connect
Extension connect
Extension
(TRX1)
Extension Number
301
Port Type
Transceiver 1 (TRX1)
Default Call
Destination Number
302 (From Radio 1 to [EXT I/O 2])
(EXT2)
Extension Number
302
Port Type
[EXT I/O 2 (EXT2)]
Outgoing Line (IP Line)
32
Default Call
Destination Number
401 (From [EXT I/O 2] to IP Phone)
Incoming Call
V/RoIP Incoming
Call Setting
Receive Port
32:302 (EXT2)
Port Settings
Transceiver 1 (TRX1) Transceiver Model:
Transceiver Model
IC-F5060/F6060 (default)
EXT I/O 2 (EXT2)
EXT Control Terminal
Input Connection Port
IP Network
(EXT Control Terminal) Valid Timing
Control Data Detect
Power for the Microphone Enable
Reference Level
(Depending on the external device)
Input Analog Gain
Input Digital Gain
(EXT Control Terminal) Reference Level
(Depending on the external device)
Output Analog Gain
Output Digital Gain
Response Waiting Time (Select a desired setting)
Restoration Waiting Time
(Notice Tone to
the Transceiver)
Calling Notice Tone
(Select a desired setting)
Send Connect
Success Tone
Disconnect Notice Tone
Send Connect
Failure Tone
Tone Level
(Continued on the next page.)