5
BRIDGE MODE SETTING SCREEN
5-90
e
Event OFF Time …………
Select the delay time until the port (B3/B4 terminal (General control input)) is
deactivated.
(Default: 1)
Range: [0.1], [0.3], [0.5], [1], [1.5], [2], [3] (second)
r
Control Input Detection …
Select the port input state of B3/B4 terminal (General control input).
(Default: Short Circuit (LOW))
When the input port is pulled up:
• Short Circuit (LOW) :
B3/B4 terminal (General control input) is connected
to the GND.
• Open Circuit (HIGH) :
B3/B4 terminal (General control input) is open.
When the input port is NOT pulled up:
•
Short Circuit (LOW)
: No voltage is applied to the B3/B4 terminal (General
control input).
•
Open Circuit (HIGH) :
A voltage is applied to the B3/B4 terminal (General
control input).
t
Control Input Pull-up Setting
Select “Enable” to internally pull up the B3/B4 terminal (General control
input).
(Default: Enable)
8. [Port Settings] Menu
M
EXT Control Terminal (continued)
VE-PG3 (Rear view)
• See Section 8 for port details.
A1~A4
A1~A4
B1~B4
B1~B4
C1~C4
C1~C4
A1~A4
A1~A4
B1~B4
B1~B4
C1~C4
C1~C4
A1~A4
A1~A4
B1~B4
B1~B4
C1~C4
C1~C4
A1~A4
A1~A4
B1~B4
B1~B4
C1~C4
C1~C4
[EXT1] port
[EXT2] port
[Port Settings]–[EXT Input 1 (EXT1)/EXT Input 2 (EXT2)]