2
BRIDGE MODE APPLICATION
2-5
2. Operation in the Unicast mode
In the Unicast mode, you can call the designated radio, using a communication port.
• In the instruction, the example of the communication as illustrated below, is used.
Area A
Area B
An example of communication the Unicast mode
Radio A
Radio B
Radio A1
Radio B1
VE-PG3
(192.168.0.3)
VE-PG3
(192.168.0.2)
[TRX1]
[LAN]
[LAN]
[TRX1]
*Enter the IP address of VE-PG3 in area A (ex. 192.168.0.2) for the VE-PG3 in area B.
**Click [Connect], and verify that "During transmit" is displayed.
Menu Item
Setting Screen
Setting Item
Item Name
Value
Operating Mode
Operating Mode
Operating Mode
Operating Mode
Bridge
IP Communication Mode
IP Communication Mode Unicast
Port Settings
Transceiver 1 (TRX1) Transceiver Model
Transceiver Model
IC-F5060
Bridge Connection Bridge Connection
Bridge Connection Point
Connection IP Address* 192.168.0.3
Connection Port Number 21500
My Station Port Number
21500
List of Bridge Connection Point Entries Connection Status**
"During transmit"
VE-PG3 (Area A)
1. Configuration
Access the VE-PG3 setting screen, and set the items as shown below.
Click