3
CONVERTER MODE APPLICATION
3-13
Menu Item
Setting Screen
Setting Item
Item Name
Value
Operating Mode
Operating Mode
Operating Mode
Operating Mode
Converter
Extension Connect Extension connect
Extension
Extension Number 32
Port Type
SIP Phone (Automatic Detection)
Password
(Enter a password)
Extension
Extension
Extension Number 401
Port Type
SIP Phone (KX-UT Series)
Password
(Enter a password)
MAC Address
(MAC address of the KX-UT series IP phone in area B)
3. Using an external headset (continued)
1
Make a cable the length you need, with two supplied connectors wired as shown, and the appropriate con-
nectors for your audio device. Then connect it to the [EXT2] on the VE-PG3 and then to your audio device.
• See Section 8 for the port details.
2
3
VE-PG3 (Rear view)
Icom’s transceiver
(IC-F5060/IC-F6060 series)
(Rear view)
(Front view)
To the external speaker jack
To the microphone connector
LINE2 LINE1
PHONE
•
The [TRX1] and [TRX2] ports (upper slots) accept the OPC-2275 connectors.
However, follow the example to correctly connect the transceiver to ONLY the [TRX1] slot.
A B C
Be sure to insert the
connectors top side up.
Bottom
Top
A
1
2
3
4
OPC-2275
A
A B C
To [TRX1] (Upper slot)
To [EXT2] (lower slot)
B
A
1 2 3 4
1 2 3 4
B
A1 A2 A3 A4
B1 B2 B3 B4
1 2 3 4
A
1 2 3 4
Connector pin configuration
A1: Audio output (OUT)
A2: Audio output ground
A3: Audio input (IN)
A4: Audio input ground
B3: Control input
B4: Control ground
2. Connection
Set the transceiver channel, volume level and TX output power, before connecting to the VE-PG3.
When all the connections are complete, turn ON the transceiver and VE-PG3’s power.
Connect the VE-PG3 and the transceiver, using the appropriate optional cable.
• Verify that both the VE-PG3 and the transceiver are turned OFF when connecting the cable.
NOTE:
• Verify that both the radio and the VE-PG3 are turned OFF when connecting or disconnecting the transceiver.
• Keep the radio away from a PC, AC adaptor and other electronic equipment. The noise emitted from those equipment
may interfere with the radio.
• When operating the radio, do not transmit near the IP telephone.