55
4
APCO P25 MODE OPERATION
D
Transmitting an Emergency call along with
an Emergency alarm
q
Hold down
[Emergency]* for the preset time period to
enter the emergency mode.
• The countdown starts immediately.
w
After the preset time period has passed, the transceiver
automatically, and repeatedly, transmits an Emergency
alarm.
• To exit the emergency mode, hold down
[Emergency] again be-
fore transmitting an Emergency alarm.
• After receiving an acknowledgement, “
ACK RECEIVED” is dis-
played (Simple and 10-key types only), and depending on the
presetting, the transceiver exits the emergency mode.
• When an acknowledgement is not received, “
NO ACKNOWLDG”
is displayed. (Simple and 10-key types only) And depending on
the presetting, the transceiver automatically transmits the micro-
phone audio (Auto TX).
e
Hold down
[PTT] to transmit an Emergency call.
• The LED indicator
(for Handhelds) or Transmit indicator (for Mo-
biles) lights red.
r
To exit the emergency mode, turn the power OFF.
*
The emergency repeat cycle must be set to ‘2’ or above.
D
Receiving an Emergency alarm
An Emergency alarm can be received only while in the Con-
ventional mode.
An emergency alarm decode action and automatic acknowl-
edgement capability should be enabled with the CS-F9010/
F9510
cloning
software
.
q
When an Emergency alarm is received;
• The LED indicator
(for Handhelds) or Busy indicator (for Mobiles)
lights green.
• Ringers sound.
• “
EA RECEIVED” and the calling station ID (or name) blink. (Sim-
ple and 10-key types only)
For Handhelds:
For Mobiles:
EA RECEIVED
INDIVIDUAL1
DSEL PAGE STAT
E A
R E C E I V E D
I N D I V I D U A L 1
The calling station ID name
w
An acknowledgement is automatically transmitted.
• The LED indicator
(for Handhelds) or Transmit indicator (for Mo-
biles) lights red.
e
Push any key (except for
[
]) to stop the display from
blinking and return to normal operation.