![Icom IC-9100 Скачать руководство пользователя страница 200](http://html.mh-extra.com/html/icom/ic-9100/ic-9100_instruction-manual_612373200.webp)
191
18
CONTROL COMMAND
s"ANDEDGEFREQUENCYSETTING
Command 02*, 1E 01, 1E 03
q
X X X
w
e
r
t
y
u
i
o
!0
!1
!2
X X X X X X X X X 2 D X X X X X X X X X X
10 Hz digit:
0–9
1 Hz digit:
0–9
1 kHz digit:
0–9
100 Hz digit:
0–9
100 kHz digit:
0–9
10 kHz digit:
0–9
10 MHz digit:
0–9
1 MHz digit:
0–9
1000 MHz digit:
0–1
100 MHz digit:
0–9
10 Hz digit:
0–9
1 Hz digit:
0–9
1 kHz digit:
0–9
100 Hz digit:
0–9
100 kHz digit:
0–9
10 kHz digit:
0–9
10 MHz digit:
0–9
1 MHz digit:
0–9
1000 MHz digit:
0–1
100 MHz digit:
0–9
Separator (fix
ed)
Lower edge
Higher edge
Edge number*:
01–30
* Edge number setting is not necessary with com-
mand 02.
s"ANDSTACKINGREGISTER
Command : 1A 01
q
X
X
X
X
w
When sending the contents, the codes, such as op-
erating frequency and operating mode*, should be
added after the register code, as shown below.
* See
t
to
%1
on ‘Memory content setting.’ (p. 195)
q
Frequency band code
Code
&REQBAND &REQUENCYRANGEUNIT-(Z
01
1.8
1.800000– 1.999999
02
3.5
3.400000– 4.099999
03
7
6.900000– 7.499999
04
10
9.900000–10.499999
05
14
13.900000–14.499999
06
18
17.900000–18.499999
07
21
20.900000–21.499999
08
24
24.400000–25.099999
09
28
28.000000–29.999999
10
50
50.000000–54.000000
11
VHF
108.000000–174.000000
12
UHF
420.000000–480.000000
13
1.2G
1240.000000–1320.000000
14
GENE
Other than above
w
Register code
Code
2EGISTERED.O
01
1 (latest)
02
2
03
3 (oldest)
For example, when reading the oldest contents in the
21 MHz band, the code “0703” is used.
s-EMORYKEYERCONTENTS
Command : 1A 02
X
q
: Channel data
w
–
&1
: Text data
X X X …… X X
01
:
M1
02
:
M2
03
:
M3
04
:
M4
s#HARACTERSCODE
#HARACTER
ASCII code
$ESCRIPTION
0–9
30–39
Number
A–Z
41–5A
Alphabetical characters
a–z
61–7A
Alphabetical characters
space
20
Word space
/
2F
Symbol
?
3F
Symbol
,
2C
Symbol
.
2E
Symbol
@
40
Symbol
^
5E
e.g., to send BT, enter ^BT
1
2A
Inserts contest number (can be
used for 1 channel only)
s#7MESSAGECONTENTS
Command : 17
Set a CW message of up to 30 characters.
s#HARACTERSCODE
#HARACTER
ASCII code
$ESCRIPTION
0–9
30–39
Number
A–Z
41–5A
Alphabetical characters
a–z
61–7A
Alphabetical characters
space
20
Word space
/
2F
Symbol
?
3F
Symbol
.
2E
Symbol
–
2D
Symbol
,
2C
Symbol
:
3A
Symbol
’
27
Symbol
(
28
Symbol
)
29
Symbol
3D
Symbol
+
2B
Symbol
”
22
Symbol
@
40
Symbol
s
“FF” stops sending CW messages.
s
“^” is used to transmit a string of characters with
no inter-character space.
D
Data content description (continued)