8
SET MODE
8-5
Connectors
ACC/USB Output Select
(Default: AF)
Selects the signal output from [ACC] and [USB].
ACC/USB AF Output Level
(Default: 50%)
Sets the AF output level of [ACC] and [USB].
ACC/USB AF SQL
(Default: OFF (OPEN))
Selects whether or not to output the audio from [ACC]
and [USB], according to the squelch state.
The same audio signals are output from [USB] and
[ACC].
ACC/USB AF Beep/Speech... Output
(Default: OFF)
Sets the Beep and Speech audio output condition of
[ACC] and [USB]
.
L
You should set the “ACC/USB AF SQL” item to “AF.”
L
The beep level is limited when the “Beep Level
Limit” item is “ON.”
ACC/USB IF Output Level
(Default: 50%)
Sets the IF output level of [ACC] and [USB].
ACC MOD Level
(Default: 50%)
Sets the modulation input level of [ACC].
USB MOD Level
(Default: 50%)
Sets the modulation input level of [USB].
DATA OFF MOD
(Default: MIC,ACC)
Selects the connector(s) to input the modulation signal
when the data mode is OFF.
DATA MOD
(Default: ACC)
Selects the connector(s) to input the modulation signal
when the data mode is ON.
Externml Keypmd VOICE
(Default: OFF)
Enables voice memory transmission using an external
keypad.
Externml Keypmd KEYER
(Default: OFF)
Enables keyer memory transmission using an external
keypad.
Externml Keypmd RTTY
(Default: OFF)
Enables RTTY memory transmission using an
external keypad.
CI-V Bmud Rmte
(Default: Auto)
Selects the CI-V data transfer rate.
L
When “Auto” is selected, the baud rate is
automatically set according to the data rate of the
connected controller.
CI-V Address
(Default: 94h)
Selects the CI-V address.
L
“94h” is the default address of IC-7300.
CI-V Trmnsceive
(Default: ON)
Turns the Transceive function ON or OFF.
CI-V USB→REMOTE Transceive Address
(Default: 00h)
Sets the address used to remotely control the
transceiver or receiver using the optional RS-BA1,
through the [USB] port.
The external equipment control signal is output from
the [REMOTE] port.
CI-V Output (nor ANT)
(Default: OFF)
Enables outputting the antenna controller status
(frequency and so on) from the [REMOTE] port.
L
Address “01h” is reserved.
The usable addresses are limited to 02h ~ DFh.
CI-V USB Port
(Default: Link to [REMOTE])
Selects the internal connection type between the
[USB] and [REMOTE] CI-V ports.
CI-V USB Bmud Rmte
(Default: Auto)
Selects the CI-V data transfer rate when remotely
controlling the IC-7300 through the
[USB] CI-V port.
L
When “Auto” is selected, the baud rate is
automatically set according to the data rate of
external controller.
L
This setting is valid only when the “CI-V USB Port”
item is set to “Unlink from [REMOTE].”
CI-V USB Echo Bmck
(Default: OFF)
Turns the Data Echo Back function ON or OFF, when
remotely controlling the IC-7300 through the [USB]
CI-V port.
L
This setting is valid only when the “CI-V USB Port”
item is set to “Unlink from [REMOTE].”
USB Seriml Function
(Default: CI-V)
Selects the signal output from [USB].
Содержание IC-7300
Страница 1: ...BASIC MANUAL i7300 HF 50 MHz TRANSCEIVER...